Craftsman 919.167321 owner manual Check wiring connection

Page 21

PROBLEM

CAUSE

CORRECTION

Regulator will

Damaged regulator.

Replace.

not shut "Off"

 

 

air outlet.

 

 

Motor will not

Motor overload protection

Let motor cool "Off"

run.

switch has tripped.

and overload switch will

 

 

automatically reset.

 

Tank pressure exceeds

Motor will start automatically

 

pressure switch "cut-in"

when tank pressure drops

 

pressure.

below "cut-in" pressure of

 

 

pressure switch.

 

Extension cord is wrong

Check for proper gauge wire

 

length or gauge.

and cord length.

 

Check valve stuck open.

Remove and clean, or

 

 

replace.

 

Loose electrical connections.

Check wiring connection

 

 

inside pressure switch and

 

 

terminal box area.

 

Possible defective motor or

Have checked by a Trained

 

starting capacitor.

Service Technician.

 

Paint spray on internal motor

Have checked by a Trained

 

parts.

Service Technician. Do not

 

 

operate the compressor in

 

 

the paint spray area. See

 

 

flammable vapor warning.

 

Pressure release valve on

Bleed the line by pushing the

 

pressure switch has not

lever on the pressure switch

 

unloaded head pressure.

to the "Off" position; if the

 

 

valve does not open, replace

 

 

switch.

 

Fuse blown, circuit breaker

1. Check fuse box for blown

 

tripped.

fuse and replace as

 

 

necessary. Reset circuit

 

 

breaker. Do not use a fuse

 

 

or circuit breaker with

 

 

higher rating than that

 

 

specified for your particular

 

 

branch circuit.

 

 

2. Check for proper fuse. You

 

 

should use a time delay

 

 

fuse.

 

 

3. Check for low voltage

 

 

conditions and/or proper

 

 

extension cord.

 

 

4. Disconnect the other

 

 

electrical appliances from

 

 

circuit or operate the

 

 

compressor on its own

 

 

branch circuit.

21 - ENG

A17883

Image 21
Contents AIR Compressor Warranty Table of ContentsSafety Guidelines Definitions Specification ChartImportant Safety Instructions Model No 919.167321What can Happen HOW to Prevent IT Risk of Explosion or Fire What can Happen HOW to Prevent ITHazard Risk to Breathing AsphyxiationRisk of Bursting Attachments & accessoriesRisk of Electrical Shock What can Happen HOW to Prevent IT Electrical Grounding Failure toRisk from Flying Objects Risk from Moving Parts Risk of HOT Surfaces What can Happen HOW to Prevent ITRisk of Unsafe Operation What can Happen HOW to Prevent IT Risk of FallingRisk from Noise Accessories AccessoriesGlossary Duty CycleInstallation AssemblyLocation of the Air Compressor Grounding can Result Electrical ShockVoltage and Circuit Protection Extension CordsOperation Know Your Air CompressorDescription of Operation Before Starting How to StopBefore Each Start-Up Pressure Release ValveHow to Start To Check Safety Valve MaintenanceCustomer Responsibilities To Drain TankAir Filter Inspection and Replacement Air Compressor Pump Intake and Exhaust ValvesAir Filter To Replace or Clean Check Valve Service and AdjustmentsTo Replace Regulator Nut Outlet Tube Pressure Relief Check Valve Outlet Pressure Gauge Regulator Quick Connect Storage Niple Regulator ArrowProblem Cause Correction TroubleshootingBeing used Check wiring connection Garantía ContenidoDefiniciones DE Normas DE Seguridad Cuadro DE EspecificacionesInstrucciones Importantes DE Seguridad Modelo Nº 919.167321Peligro Riesgo Respiratorio Asfixia¿QUÉ Puede SUCEDER? Cómo Evitarlo Elementos y accesorios Riesgo DE ExplosiónRiesgo DE Superficies Calientes Riesgo DE Objetos DespedidosRiesgo DE Operación Insegura Riesgo POR Piezas Móviles ¿QUÉ Puede SUCEDER? Cómo EvitarloRiesgo POR Ruidos Riesgo DE CaídasAccesorios GlosarioCiclo DE Servicio AccesoriosInstalación EnsamblajeDesempaque Ubicación del compresor de aireCables de extensión eléctrica Protección del voltaje y del circuitoRiesgo de Operación Operación On/Auto Off Switch Safet y Valve RegulatorConozca su compresor de aire Descripción de operacionesCómo detenerla Antes de poner en marchaProcedimiento para el asentamiento Antes de cada puesta en marchaCómo poner en marcha MantenimientoResponsabilidades del cliente Cómo verificar la válvula de seguridadFiltro de Aire Inspección y reemplazo Cómo drenar el tanqueSuperficies calientes. Riesgo Filtro de airePara reemplazar o limpiar la válvula retención Servicio Y AjustesTuerca Salida Tubo aliviador De presión Dora TuercaRegulador Conector rápido Para reemplazar el reguladorRegulador Regulador FlechaRiesgo de Explosión. El agua AlmacenajeProblème Cause Correction DépannagePression sur le Le relevé deManomètre du Soire est utiliséTourne pas Le moteur neA17883 Contratos de Protección Maestra Master Protection AgreementsMY-HOME Sears Parts and Repair CenterCanada