Craftsman 919.167321 owner manual Assembly, Installation, Location of the Air Compressor

Page 10

ASSEMBLY

Unpacking

1.Remove unit from carton and discard all packaging.

INSTALLATION

HOW TO SET UP YOUR UNIT

Location of the Air Compressor

Locate the air compressor in a clean, dry and well ventilated area.

The air compressor should be located at least 12" (30.5 cm) away from the wall or other obstructions that will interfere with the flow of air.

The air compressor pump and shroud are designed to allow for proper cooling. The ventilation openings on the compressor are necessary to maintain proper operating temperature. Do not place rags or other containers on or near these openings.

GROUNDING INSTRUCTIONS

Risk of Electrical Shock. In the event

of a short circuit, grounding reduces the risk of shock by providing an escape wire for the electric current. This air compressor must be properly grounded.

The portable air compressor is equipped with a cord having a grounding wire with an appropriate grounding plug (see following illustrations).

1.The cord set and plug with this unit contains a grounding pin. This plug MUST be used with a grounded outlet.

IMPORTANT: The outlet being used must be installed and grounded in accordance with all local codes and ordinances.

2.Make sure the outlet being used has the same configuration as the grounded plug. DO NOT USE AN ADAPTER. See illustration.

Plug

Grounded

Outlets

Grounding Pin

3.Inspect the plug and cord before each use. Do not use if there are signs of damage.

4.If these grounding instructions are not completely understood, or if in doubt as to whether the compres- sor is properly grounded, have the installation checked by a qualified electrician.

Risk of Electrical

Shock. IMPROPER

GROUNDING CAN RESULT IN

ELECTRICAL SHOCK.

Do not modify the plug provided. If it does not fit the available outlet, a correct outlet should be installed by a qualified electrician.

Repairs to the cord set or plug MUST be made by a qualified electrician.

A17883

10 - ENG

Image 10
Contents AIR Compressor Table of Contents WarrantyImportant Safety Instructions Specification ChartSafety Guidelines Definitions Model No 919.167321Hazard Risk of Explosion or Fire What can Happen HOW to Prevent ITWhat can Happen HOW to Prevent IT Risk to Breathing AsphyxiationAttachments & accessories Risk of BurstingElectrical Grounding Failure to Risk of Electrical Shock What can Happen HOW to Prevent ITRisk from Flying Objects Risk of HOT Surfaces What can Happen HOW to Prevent IT Risk from Moving PartsRisk of Falling Risk of Unsafe Operation What can Happen HOW to Prevent ITRisk from Noise Glossary AccessoriesAccessories Duty CycleLocation of the Air Compressor AssemblyInstallation Grounding can Result Electrical ShockExtension Cords Voltage and Circuit ProtectionKnow Your Air Compressor OperationDescription of Operation Before Each Start-Up How to StopBefore Starting Pressure Release ValveHow to Start Customer Responsibilities MaintenanceTo Check Safety Valve To Drain TankAir Compressor Pump Intake and Exhaust Valves Air Filter Inspection and ReplacementAir Filter To Replace Regulator Service and AdjustmentsTo Replace or Clean Check Valve Nut Outlet Tube Pressure Relief Check ValveNiple StorageOutlet Pressure Gauge Regulator Quick Connect Regulator ArrowTroubleshooting Problem Cause CorrectionBeing used Check wiring connection Contenido GarantíaInstrucciones Importantes DE Seguridad Cuadro DE EspecificacionesDefiniciones DE Normas DE Seguridad Modelo Nº 919.167321Riesgo Respiratorio Asfixia Peligro¿QUÉ Puede SUCEDER? Cómo Evitarlo Riesgo DE Explosión Elementos y accesoriosRiesgo DE Objetos Despedidos Riesgo DE Superficies CalientesRiesgo POR Piezas Móviles ¿QUÉ Puede SUCEDER? Cómo Evitarlo Riesgo DE Operación InseguraRiesgo DE Caídas Riesgo POR RuidosCiclo DE Servicio GlosarioAccesorios AccesoriosDesempaque EnsamblajeInstalación Ubicación del compresor de aireProtección del voltaje y del circuito Cables de extensión eléctricaRiesgo de Operación Conozca su compresor de aire On/Auto Off Switch Safet y Valve RegulatorOperación Descripción de operacionesProcedimiento para el asentamiento Antes de poner en marchaCómo detenerla Antes de cada puesta en marchaResponsabilidades del cliente MantenimientoCómo poner en marcha Cómo verificar la válvula de seguridadSuperficies calientes. Riesgo Cómo drenar el tanqueFiltro de Aire Inspección y reemplazo Filtro de aireTuerca Salida Tubo aliviador Servicio Y AjustesPara reemplazar o limpiar la válvula retención De presión Dora TuercaRegulador Para reemplazar el reguladorRegulador Conector rápido Regulador FlechaAlmacenaje Riesgo de Explosión. El aguaDépannage Problème Cause CorrectionManomètre du Le relevé dePression sur le Soire est utiliséLe moteur ne Tourne pasA17883 Master Protection Agreements Contratos de Protección MaestraSears Parts and Repair Center MY-HOMECanada