Craftsman 919.167321 owner manual Storage, Outlet Pressure Gauge Regulator Quick Connect, Niple

Page 18

Outlet

Pressure

Gauge

Regulator Quick

Connect

4.Remove the regulator.

5.Apply pipe sealant tape to the nipple.

Niple

6.Assemble the regulator and orient as shown.

Regulator

NOTE: Arrow indicates flow of air. Make sure it is pointing in the direction of air flow.

7.Reapply pipe sealant to outlet pressure gauge and quick connect.

Regulator

Arrow

8.Reassemble outlet pressure gauge and quick connect. Orient outlet pressure gauge to read correctly. Tighten quick connect with wrench.

STORAGE

Before you store the air compressor, make sure you do the following:

1.Review the Maintenance section on the preceding pages and per- form scheduled maintenance as necessary.

2.Set the On/Auto/Off lever to "Off" and unplug unit.

3.Turn the regulator counterclock- wise and set the outlet pressure to zero.

4.Remove the air tool or accessory.

5.Pull ring on safety valve allowing air to bleed from the tank until tank pressure is approximately 20 psi. Release safety valve ring.

6.Drain water from air tank by open- ing drain valve on bottom of tank.

Risk of Bursting. Water will condense

in the air tank. If not drained, water will corrode and weaken the air tank causing a risk of air tank rupture.

7.After the water has been drained, close drain valve by turning clock- wise.

NOTE: If drain valve is plugged, release all air pressure. The valve can then be removed, cleaned, then reinstalled.

8.Protect the electrical cord and air hose from damage (such as being stepped on or run over). Wind them loosely around the com- pressor handle.

9.Store the air compressor in a clean and dry location.

A17883

18 - ENG

Image 18
Contents AIR Compressor Table of Contents WarrantyImportant Safety Instructions Specification ChartSafety Guidelines Definitions Model No 919.167321Hazard Risk of Explosion or Fire What can Happen HOW to Prevent ITWhat can Happen HOW to Prevent IT Risk to Breathing AsphyxiationAttachments & accessories Risk of BurstingRisk of Electrical Shock What can Happen HOW to Prevent IT Electrical Grounding Failure toRisk from Flying Objects Risk of HOT Surfaces What can Happen HOW to Prevent IT Risk from Moving PartsRisk of Unsafe Operation What can Happen HOW to Prevent IT Risk of FallingRisk from Noise Glossary AccessoriesAccessories Duty CycleLocation of the Air Compressor AssemblyInstallation Grounding can Result Electrical ShockExtension Cords Voltage and Circuit ProtectionOperation Know Your Air CompressorDescription of Operation Before Each Start-Up How to StopBefore Starting Pressure Release ValveHow to Start Customer Responsibilities Maintenance To Check Safety Valve To Drain TankAir Filter Inspection and Replacement Air Compressor Pump Intake and Exhaust ValvesAir Filter To Replace Regulator Service and AdjustmentsTo Replace or Clean Check Valve Nut Outlet Tube Pressure Relief Check ValveNiple StorageOutlet Pressure Gauge Regulator Quick Connect Regulator ArrowTroubleshooting Problem Cause CorrectionBeing used Check wiring connection Contenido GarantíaInstrucciones Importantes DE Seguridad Cuadro DE EspecificacionesDefiniciones DE Normas DE Seguridad Modelo Nº 919.167321Peligro Riesgo Respiratorio Asfixia¿QUÉ Puede SUCEDER? Cómo Evitarlo Riesgo DE Explosión Elementos y accesoriosRiesgo DE Objetos Despedidos Riesgo DE Superficies CalientesRiesgo POR Piezas Móviles ¿QUÉ Puede SUCEDER? Cómo Evitarlo Riesgo DE Operación InseguraRiesgo DE Caídas Riesgo POR RuidosCiclo DE Servicio GlosarioAccesorios AccesoriosDesempaque EnsamblajeInstalación Ubicación del compresor de aireCables de extensión eléctrica Protección del voltaje y del circuitoRiesgo de Operación Conozca su compresor de aire On/Auto Off Switch Safet y Valve RegulatorOperación Descripción de operacionesProcedimiento para el asentamiento Antes de poner en marchaCómo detenerla Antes de cada puesta en marchaResponsabilidades del cliente MantenimientoCómo poner en marcha Cómo verificar la válvula de seguridadSuperficies calientes. Riesgo Cómo drenar el tanqueFiltro de Aire Inspección y reemplazo Filtro de aireTuerca Salida Tubo aliviador Servicio Y AjustesPara reemplazar o limpiar la válvula retención De presión Dora TuercaRegulador Para reemplazar el reguladorRegulador Conector rápido Regulador FlechaAlmacenaje Riesgo de Explosión. El aguaDépannage Problème Cause CorrectionManomètre du Le relevé dePression sur le Soire est utiliséLe moteur ne Tourne pasA17883 Master Protection Agreements Contratos de Protección MaestraMY-HOME Sears Parts and Repair CenterCanada