Xantrex Technology 815-2524-02, 815-3524 Planning Preparations, AC, DC, and Network Components

Page 21

Planning Preparations

AC, DC, and Network Components

For a successful installation, you need to plan for AC, DC, and network components of the power system. The AC and DC components are described in this section and illustrated in Figure 3 on page 8.

AC components include:

AC Input/AC Output

AC Loads

AC Disconnect and Over-Current Protection Device

Distribution Panels

AC Wiring

DC components include:

24-volt Batteries

DC Cabling

DC Disconnects and Over-Current Devices

DC Grounding

Network considerations for Freedom SW only include:

Cables, connectors, network connectors, and terminators for the

only.

 

 

SCP and Automatic Generator Start, if installing.

 

 

system guide to determine the type of network layout to install,personnel

 

Detailed information on planning and installing your network is

 

 

available in the Xanbus System Installation Guide. Refer to the

 

 

as well as guidelines for installing the network. This guide is

qualifiedbyuseforguideThis

 

available for download at www.xantrex.com

 

 

975-0697-01-01

7

Image 21
Contents Freedom SW Sine Wave Inverter/Chargers Page This guide for use by qualified Purpose About This GuideImportant Safety Instructions Electrical Shock and Fire HazardElectrical Shock Hazard Explosion Hazard Fire and Burn HazardPrecautions When Working With Batteries Risk of Damage to the INVERTER/CHARGER Exposure to Chemicals and Gases HazardLimitations on USE RegulatoryPage Contents Page This guide for use by qualified installers only Page Introduction Materials List Materials List Freedom SW 230V Installation GuideBefore You Begin the Installation Installation InformationInstallation Codes Electrical Shock and Fire HazardsXanbus System About the Xanbus SystemAbout the Xanbus System Xanbus-enabled Products and AccessoriesTwo Key Performance Factors Planning the InstallationSize and Length of DC Cables Mounting Location of the Freedom SWAC, DC, and Network Components Planning PreparationsPlanning Preparations Planning Preparations AC Input AC ComponentsAC Disconnect and Over-Current Protection Device AC OutputDistribution Panels AC WiringFreedom SW ModelsBatteries DC ComponentsDC Cabling Fire HazardDC Disconnects and Over-Current Devices DC GroundingMarine Applications1 To unpack and inspect Heavy ItemInstallation Tools and Materials ToolsMaterials Overview Installing the Inverter/ChargerChoosing a Location for the Inverter/Charger Fire and Explosion HazardHeat Hazard Safe Mounting the Inverter/Charger ConsiderationsTo mount the inverter/charger Approved Mounting Orientation Orientation? Comment Orientation Approved Mounting Orientation? Comment This guide for use by qualified Connecting the AC Input and AC Output Wires General AC Wiring ConsiderationsFIRE, Electrical SHOCK, and Energy Hazards Correct Batter Polarity will Cause Damage to Connecting AC Input WiresInstalling the Inverter/Charger Connecting the AC Output Wires To make the AC output wiring connectionsEquipment Damage DC Connection Precautions Connecting the DC CablesRecommended Cable Sizes and Lengths and Fuse Size Preparing the CablesGuidelines for Routing the DC Cables Connecting the DC Cables to the Inverter/Charger Equipment Damage DUE to Reverse PolarityTo connect the DC cables DC Cable Connections To connect the chassis ground Mounting Options Connecting the Battery Temperature Sensor BTSTo mount the sensor on the negative battery terminal Mounting to the Negative Battery TerminalBTS port To mount the sensor on the battery case Mounting to the Side of the Battery CaseTo connect the Freedom SW 230V to the Xanbus network Connecting to the NetworkPerforming Checks Prior to Initial Start-Up Testing in Invert Mode Testing Your InstallationTesting in Charge Mode and AC Bypass Mode Installation CompleteTo verify that the Freedom SW 230V starts charging Stacking Features Parallel Stacking Connect the stacked system as follows DC Connections for Stacked InvertersNeutral Wiring for Stacked Inverters To configure the system for stacking Configuring System for Stacked OperationWiring Schematic Search Mode Operation in Parallel StackingDisabling Search Mode on the Master Unit Setting Search Mode on the Slave UnitCalculations Charger Settings in a Dual Freedom SW ConfigurationExamples To set the Max Chg Rate % setting in each Freedom SWTo set the Max Chg Rate % setting in each Freedom SW To set the Max Chg Rate % setting in each Freedom SW Freedom SW Physical Specifications Inverter/Charger Physical SpecificationsBattery Bank Sizing Battery InformationCalculating Battery Size Estimating Battery RequirementsBattery AMP-HOURS Used = AC WATT-HOURS÷10 Watts = Volts × AmpsDaily watt-hours needed Battery Banks Battery Bank Sizing WorksheetRestrictions on Motor Size Battery Information Battery Sizing Worksheet Battery Series Connection Battery Cabling and Hook-up ConfigurationsBattery Series-Parallel Connections Environmental Specifications SpecificationsInverter Specifications Charger Specifications Transfer and General Specifications Inverter Drip Shield Installation To install the drip shieldShock Hazard Drip Shield Placement Desktop Mount 20 mm No clearance required here Page Page Schneider Electric Solar Inverters USA Inc