Planning Preparations
INVERTER AC SUB PANEL (TYPICAL)
15 A | TO AC APPLIANCE |
|
IMPORTANT: Read Owner’s and Installation Guides prior to installation. Always refer to local and national electrical codes for proper wire and breaker
20 A
LOADS
sizes prior to installation.
See “DC Cabling” on page 13 and “DC Disconnects and Over- Current Devices” on page 14 for cable sizes and fuse ratings.
230 V AC OUT
2524 and 3524 Inverter/Charger
230 V AC IN
Battery (Bank) 24 V
Neutral
GND
HARDWIRE CONNECTIONS | MAIN ELECTRICAL PANEL | |||
|
|
| ||
|
|
| MAIN |
|
30 A MAX in |
30 A
HOT BUS
HOT = BROWN, BLACK, OR GREY
NEUTRAL = BLUE
GND = GREEN WITH YELLOW STRIPE
Neutral
GND
FROM SHORE OR | IMPORTANT: In Australia, connection to |
GENERATOR POWER | shore power that is supplied by the utility grid, |
| |
| must follow local and national wiring rules. |
This guide for use by qualified personnel only.
NOTE: The DC grounding conductor may be one size smaller than the minimum size conductor required for the DC current carrying conductors providing the overcurrent protection device in the DC positive conductor is rated no greater than 135% of the ampacity of the DC grounding conductor and the conductor is no smaller than 2mm2.
Figure 4 Wiring and Breakers Block Diagram for Freedom SW 230V 2524 / 3524
| 9 |