Porter-Cable C2555 instruction manual Pressure reading

Page 22

 

PROBLEM

CAUSE

CORRECTION

 

Pressure reading

It is normal for "some"

If there is an excessive amount

 

on the regulated

pressure drop to occur.

of pressure drop when the

 

pressure gauge

 

accessory is used, adjust the

 

 

regulator as instructed in the

 

(if equipped)

 

 

 

Operation section.

 

drops when an

 

 

 

NOTE: Adjust the regulated

 

accessory is

 

 

 

pressure under flow conditions

 

used.

 

 

 

(while accessory is being

 

 

 

 

 

 

used).

 

 

 

 

 

Air leak from

Possible defect in safety

Operate safety valve manually

 

safety valve.

valve.

by pulling on ring. If valve still

 

 

 

leaks, it should be replaced.

 

 

 

 

 

Compressor is

Prolonged excessive use of

Decrease amount of air usage.

 

not supplying

air.

Check the accessory air

 

enough air to

Compressor is not large

 

operate

enough for air requirement.

requirement. If it is higher than

 

accessories.

 

the SCFM or pressure supplied

 

 

 

by your air compressor, you

 

 

 

need a larger compressor.

 

 

Hole in hose.

Check and replace if required.

 

 

Check valve restricted.

Remove and clean, or replace.

 

 

Air leaks.

Tighten fittings.

 

 

Restricted air intake filter

Clean or replace air intake

 

 

 

filter. Do not operate the air

 

 

 

compressor with the filter

 

 

 

removed. Refer to the "Air

 

 

 

Filter" paragraph in the

 

 

 

"Maintenance " section.

 

 

 

 

 

Restricted air

Dirty air filter.

Clean or replace. See Air Filter

 

intake

 

paragraph in the Maintenance

 

 

 

section.

 

 

 

 

 

Regulator knob

Damaged regulator

Replace

 

has continuous

 

 

 

air leak.

 

 

 

 

 

 

 

Regulator will

Damaged regulator

Replace

 

not shut off air

 

 

 

outlet.

 

 

 

 

 

 

D29795

22- ENG

Image 22
Contents Model C2555Or serious injury Minor or moderate injury Safety Guidelines DefinitionsImportant Safety Instructions Death or serious injuryLocation away from compressor Spray area. An additional length of hoseExplosion May be required Fire, do not allow the compressor toAttachments & Accessories What Could HappenRepairs attempted by unqualified Safety equipment must be properlyElectricity. Like any other electrically Air to all applicable local and federalHot for several minutes after operation Or attempt maintenance until unit hasResult in serious burns Do not reach around protective shroudsFire, Inhalation, Damage to Vehicle Surfaces Glossary SpecificationsDuty Cycle Accessories AssemblyTo Add Oil To Pump Installation Location of the Air CompressorExtension Cords Voltage and Circuit ProtectionOperation Know Your Air Compressor Description of OperationBefore Starting How to StopDipstick How to Start Before Each Start-UpCustomer Responsibilities MaintenanceTo Check Safety Valve To Drain TankOil ChangingAir Filter Inspection and Replacement MotorService and Adjustments To Replace RegulatorStorage Recommended Handle Alternate Handle StorageTroubleshooting Pressure reading Problem Cause Correction Problem Cause Correction ENG D29795 Limited Warranty Responsibility of Original Purchaser initial UserManual de Moderadas Definiciones DE Normas DE SeguridadMuerte o lesiones serias Lesiones serias Causar daños en la propiedadInstrucciones Importantes DE Seguridad Cómo prevenirloAdvertencia Riesgo de Explosión Qué puede occurrir Cómo prevenirlo31- SP D29795 Advertencia Riesgo de Quemaduras Qué puede occurrir Advertencia Riesgo de Caída Qué puede occurrirAdvertencia Riesgo de Operación Lasegura Qué puede occurrir Especificaciones GlosarioCiclo DE Servicio C2555Accesorios EnsambladoAgregado de aceite a la bomba Enchufe Toma InstalaciónUbicación del compresor de aire Espiga de conexión a tierraCables de extensión eléctrica Protección del voltaje y del circuitoConozca su compresor de aire OperaciónDescripción de operaciones Cómo detenerla Cómo utilizar su unidadAntes de poner en marcha Procedimiento para el asentamientoAntes de cada puesta en marcha Cómo poner en marchaCómo drenar el tanque MantenimientoCómo verificar la válvula de seguridad Tanque, creando el riesgo de su ruptura o explosiónCambio AceiteVerifique Filtro de Aire Inspección y reemplazo Servicio Y Ajustes Para reemplazar el reguladorAlmacenaje Guía DE Diagnóstico DE Problemas Desciende cuando 49- SP D29795 D29795 50- SP Nota Garantía Limitada Responsabilidad DEL Comprador Original Usuario inicialManuel Ou la mort Causer des blessures mineures ou Moyennes Mesures DE Sécurité DéfinitionsConsignes DE Sécurité Importantes Évité, peut causer des dommages à laConserver ces directives Avertissement Risque dexplosion ou dincendie PréventionRisque Prévention Avertissement Risque déclatementAvertissement Risque de projection dobjets Avertissement Risque de choc électrique Avertissement Risque par inhalationAvertissement Risque relié aux pièces mobiles Avertissement Risque de brûluresAvertissement Risque de chute Risque Avertissement Risque dune utilisation dangereuseLexique Cycle DE ServiceNo de modèle C2555 Accessoires AssemblageAjout dhuile à la pompe Emplacement du compresseur dair Montage DE LappareilRallonges Protection contre la surtension et protection du circuitUtilisation Familiarisez-vous avec votre compresseur dairAvant le démarrage Arrêt de lappareilProcédures de rodage Avant chaque mise en marche Mise en marcheResponsabilités du consommateur EntretienVérification de la soupape de sûreté Vidange du réservoirVérification HuileVidange Filtre à air Inspection et remplacement MoteurRemplacement du régulateur Entretien ET RéglagesRangement Recommandé DES Poignées Rangement Alternatif RangementDépannage Accessoires Exigences en air Le moteur ne Bruit de Remarque D29795 78- FR 79- FR D29795 Garantie Limitée Responsabilité DE Lacheteur Dorigine utilisateur initial