INSTALLATION

HOW TO SET UP YOUR UNIT

Location of the Air Compressor

Locate the air compressor in a clean, dry, and well ventilated area.

The air compressor should be located at least 12" away from the wall or other obstructions that will interfere with the flow of air.

The air filter must be kept clear of obstructions which could reduce air flow to the air compressor.

The air compressor requires fresh air flow for proper cooling. DO NOT

ALLOW THE COMPRESSOR TO GET WET.

GROUNDING INSTRUCTIONS

RISK OF ELECTRICAL SHOCK. In the event of a short circuit, grounding reduces the risk of shock by providing

an escape wire for the electric current. This air compressor must be properly grounded.

The portable air compressor is equipped with a cord having a grounding wire with an appropriate grounding plug (see following illustrations).

1.The cord set and plug with this unit contains a grounding pin. This plug MUST be used with a grounded outlet.

IMPORTANT: The outlet being used must be installed and grounded in accordance with all local codes and ordinances.

2.Make sure the outlet being used has

the same configuration as the

Plug

 

grounded plug. DO NOT USE AN

Grounded

ADAPTER. See illustration.

Outlets

3. Inspect the plug and cord before each

 

use. Do not use if there are signs of

 

damage.

Grounding Pin

4.If these grounding instructions are not

completely understood, or if in doubt as to whether the compressor is properly grounded, have the installation checked by a qualified electrician.

Risk of Electrical Shock. IMPROPER GROUNDING CAN RESULT IN ELECTRICAL SHOCK.

Do not modify the plug provided. If it does not fit the available outlet, a correct outlet should be installed by a qualified electrician.

Repairs to the cord set or plug MUST be made by a qualified electrician.

11- ENG

D29795

Image 11
Contents C2555 ModelDeath or serious injury Safety Guidelines DefinitionsImportant Safety Instructions Or serious injury Minor or moderate injuryFire, do not allow the compressor to Spray area. An additional length of hoseExplosion May be required Location away from compressorWhat Could Happen Attachments & AccessoriesAir to all applicable local and federal Safety equipment must be properlyElectricity. Like any other electrically Repairs attempted by unqualifiedDo not reach around protective shrouds Or attempt maintenance until unit hasResult in serious burns Hot for several minutes after operationFire, Inhalation, Damage to Vehicle Surfaces Duty Cycle SpecificationsGlossary Assembly AccessoriesTo Add Oil To Pump Location of the Air Compressor InstallationVoltage and Circuit Protection Extension CordsKnow Your Air Compressor Description of Operation OperationDipstick How to StopBefore Starting Before Each Start-Up How to StartTo Drain Tank MaintenanceTo Check Safety Valve Customer ResponsibilitiesChanging OilMotor Air Filter Inspection and ReplacementTo Replace Regulator Service and AdjustmentsRecommended Handle Alternate Handle Storage StorageTroubleshooting Pressure reading Problem Cause Correction Problem Cause Correction ENG D29795 Responsibility of Original Purchaser initial User Limited WarrantyManual de Lesiones serias Causar daños en la propiedad Definiciones DE Normas DE SeguridadMuerte o lesiones serias ModeradasCómo prevenirlo Instrucciones Importantes DE SeguridadQué puede occurrir Cómo prevenirlo Advertencia Riesgo de Explosión31- SP D29795 Advertencia Riesgo de Caída Qué puede occurrir Advertencia Riesgo de Quemaduras Qué puede occurrirAdvertencia Riesgo de Operación Lasegura Qué puede occurrir C2555 GlosarioCiclo DE Servicio EspecificacionesEnsamblado AccesoriosAgregado de aceite a la bomba Espiga de conexión a tierra InstalaciónUbicación del compresor de aire Enchufe TomaProtección del voltaje y del circuito Cables de extensión eléctricaDescripción de operaciones OperaciónConozca su compresor de aire Procedimiento para el asentamiento Cómo utilizar su unidadAntes de poner en marcha Cómo detenerlaCómo poner en marcha Antes de cada puesta en marchaTanque, creando el riesgo de su ruptura o explosión MantenimientoCómo verificar la válvula de seguridad Cómo drenar el tanqueVerifique AceiteCambio Filtro de Aire Inspección y reemplazo Para reemplazar el regulador Servicio Y AjustesAlmacenaje Guía DE Diagnóstico DE Problemas Desciende cuando 49- SP D29795 D29795 50- SP Nota Responsabilidad DEL Comprador Original Usuario inicial Garantía LimitadaManuel Évité, peut causer des dommages à la Mesures DE Sécurité DéfinitionsConsignes DE Sécurité Importantes Ou la mort Causer des blessures mineures ou MoyennesAvertissement Risque dexplosion ou dincendie Prévention Conserver ces directivesAvertissement Risque de projection dobjets Avertissement Risque déclatementRisque Prévention Avertissement Risque par inhalation Avertissement Risque de choc électriqueAvertissement Risque de chute Avertissement Risque de brûluresAvertissement Risque relié aux pièces mobiles Avertissement Risque dune utilisation dangereuse RisqueNo de modèle C2555 Cycle DE ServiceLexique Assemblage AccessoiresAjout dhuile à la pompe Montage DE Lappareil Emplacement du compresseur dairProtection contre la surtension et protection du circuit RallongesFamiliarisez-vous avec votre compresseur dair UtilisationProcédures de rodage Arrêt de lappareilAvant le démarrage Mise en marche Avant chaque mise en marcheVidange du réservoir EntretienVérification de la soupape de sûreté Responsabilités du consommateurVidange HuileVérification Moteur Filtre à air Inspection et remplacementEntretien ET Réglages Remplacement du régulateurRangement Rangement Recommandé DES Poignées Rangement AlternatifDépannage Accessoires Exigences en air Le moteur ne Bruit de Remarque D29795 78- FR 79- FR D29795 Responsabilité DE Lacheteur Dorigine utilisateur initial Garantie Limitée