Bryant 580J*04--12 appendix Medium Static Option High Static Option

Page 55

APPENDIX III. FAN PERFORMANCE (cont.)

580J*04

3 Phase

3 Ton Horizontal Supply

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)

 

 

 

CFM

 

0.2

 

0.4

 

0.6

 

0.8

 

1.0

RPM

BHP

RPM

BHP

RPM

 

BHP

 

 

RPM

BHP

RPM

BHP

 

 

 

 

 

 

 

Field---Supplied Drive1

 

Standard Static Option

 

 

 

Medium Static Option

900

 

553

0.14

681

0.22

782

0.32

 

 

870

0.42

948

0.53

975

 

575

0.16

700

0.25

801

0.35

 

 

888

0.46

965

0.57

1050

 

597

0.18

720

0.28

820

0.38

 

 

906

0.49

983

0.61

1125

 

620

0.21

741

0.31

839

0.42

 

 

925

0.54

1001

0.66

1200

 

643

0.23

762

0.34

 

 

0.46

 

 

944

0.58

1020

0.71

859

 

 

 

1275

 

667

0.27

783

0.38

879

0.50

 

963

0.63

1038

0.76

1350

 

691

0.30

805

0.42

900

0.55

 

983

0.68

1057

0.82

1425

 

715

0.34

827

0.47

920

0.60

 

1002

0.74

1076

0.88

1500

 

740

0.38

849

0.52

941

0.66

 

1023

0.80

1096

0.95

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)

 

 

 

CFM

 

 

1.2

 

1.4

 

1.6

1.8

 

 

2.0

 

RPM

BHP

RPM

BHP

RPM

 

BHP

 

 

RPM

BHP

RPM

BHP

 

 

 

 

 

 

 

 

 

Medium Static Option

 

 

 

 

 

 

High Static Option

 

900

 

1019

0.64

1084

0.76

1146

0.89

 

1203

1.02

1258

1.16

975

 

1036

0.69

1101

0.81

1162

0.94

 

1219

1.08

1274

1.22

1050

 

1053

0.74

1118

0.86

1179

1.00

1236

1.14

1290

1.28

1125

 

1071

0.79

1135

0.92

1196

1.06

1253

1.20

1307

1.35

1200

 

1089

0.84

1153

0.98

1213

1.12

1270

1.27

1324

1.42

1275

 

1107

0.90

 

 

1231

1.19

1287

1.34

1341

1.50

 

1171

1.04

1350

 

1126

0.96

1189

1.11

1249

1.26

1305

1.42

1358

1.58

1425

 

1144

1.03

1208

1.18

1267

1.34

1323

1.50

1376

1.66

1500

 

1163

1.10

1226

1.25

1285

1.41

1341

1.58

1394

1.75

NOTE: For more information, see General Fan Performance Notes on page 53.

 

 

 

 

 

 

1. Recommend using field--- supplied drive (part number KR11AG006) and belt (part number KR30AE039)

 

 

580J*04

3 Phase

3 Ton Vertical Supply

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)

 

 

 

CFM

 

0.2

 

0.4

 

0.6

0.8

 

1.0

 

RPM

BHP

RPM

BHP

RPM

 

BHP

RPM

BHP

RPM

BHP

 

 

 

Field---Supplied Drive1

 

Standard Static Option

Medium Static Option

 

900

567

0.15

688

0.22

786

0.30

871

0.37

947

0.44

975

591

0.17

710

0.26

807

0.34

891

0.42

966

0.49

1050

615

0.20

732

0.29

828

0.38

911

0.47

985

0.55

1125

641

0.23

755

0.33

849

0.42

931

0.52

1005

0.61

1200

666

0.26

778

0.37

 

 

0.47

952

0.57

1025

0.67

871

 

1275

693

0.29

802

0.41

893

0.53

974

0.63

1046

0.74

1350

719

0.33

826

0.46

916

0.58

995

0.70

1067

0.81

1425

746

0.38

850

0.51

939

0.64

1017

0.76

1088

0.89

1500

773

0.42

 

 

963

0.70

1040

0.84

1110

0.96

875

0.57

 

 

 

 

 

 

 

 

 

 

 

 

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)

 

 

 

CFM

 

1.2

 

1.4

 

1.6

1.8

 

2.0

 

RPM

BHP

RPM

BHP

RPM

 

BHP

RPM

BHP

RPM

BHP

 

 

 

 

 

Medium Static Option

 

 

 

 

High Static Option

 

900

1016

0.51

1080

0.57

1139

0.64

1195

0.71

1249

0.77

975

1034

0.57

1098

0.64

1157

0.72

1213

0.79

1266

0.86

1050

1053

0.63

1116

0.71

 

 

0.79

1231

0.87

1284

0.95

1176

 

1125

1073

0.70

1135

0.79

1194

0.87

1250

0.96

1302

1.04

1200

1093

0.77

1155

0.87

1213

0.96

1268

1.05

1321

1.14

1275

1113

0.85

 

 

1232

1.05

1287

1.15

1339

1.25

1174

0.95

1350

1133

0.92

1194

1.03

1252

1.14

1307

1.25

1358

1.35

1425

1154

1.01

1215

1.12

1272

1.24

1326

1.35

1378

1.46

1500

 

 

1235

1.22

1292

1.34

1346

1.46

1397

1.58

1175

1.09

NOTE: For more information, see General Fan Performance Notes on page 53. Boldface indicates field--- supplied drive is required.

1. Recommend using field--- supplied fan pulley (part number KR11AG006) and belt (part number KR30AE039).

580J

55

Image 55
Contents Safety Considerations Table of ContentsGeneral Unit Arrangement and AccessRoutine Maintenance Seasonal MaintenanceReturn Air Filters HeatingEconomizer or Outside Air Damper Air Filters and ScreensElectrical Shock Hazard Adjustable-Pitch Pulley on MotorSupply FAN Blower Section Supply Fan Belt-DriveRemove Surface Loaded Fibers Condenser Coil Maintenance and Cleaning RecommendationCooling Condenser CoilTwo-Row Coils Periodic Clean Water RinseRoutine Cleaning of Coil Surfaces One-Row CoilUnit Damage Hazard Refrigerant System Pressure Access PortsCleaning the Evaporator Coil Evaporator CoilNo Charge To Use Cooling Charging ChartsPuronr R410A Refrigerant Refrigerant ChargeCooling Charging Charts Cooling Charging ChartsCooling Charging Charts C08437 C08438 C08439 Condenser-Fan Location Troubleshooting Cooling SystemCompressor Filter DrierProblem Cause Remedy Cooling Service AnalysisUnit Connect Primary Transformer Convenience OutletsConnections Controller Smoke DetectorsSystem SensorSmoke Detector Locations Completing Installation of Return Air Smoke SensorReturn Air Sensor Operating Position Fiop Smoke Detector Wiring and ResponseDirty Controller Test Sensor Alarm TestController Alarm Test Sensor and Controller TestsRemote Station Test Remote Test/Reset Station Dirty Sensor TestDetector Cleaning Changing the Dirt Sensor TestControl or Indicator Description IndicatorsDetector Indicators Alarm StateRelief Device TroubleshootingProtective Devices Compressor ProtectionNatural Gas Supply Line Pressure Ranges GAS Heating SystemControl Circuit Fuel Types and PressuresLiquid Propane Manifold Pressure Ranges Flue Gas PassagewaysCombustion-Air Blower Liquid Propane Supply Line Pressure RangesEquipment Damage Hazard Removal and Replacement of Gas TrainCleaning and Adjustment Burners and IgnitersLimit Switch Check Unit Operation and Make Necessary Adjust- mentsBurner Ignition Spark Adjustment LED Error Code Description Orifice ReplacementLED Indication Error Code Description Outputs Integrated Gas Control IGC Board IGC ConnectionsDrill Size Part Number Orifice SizesAltitude Compensation* 04-07 Small Chassis Orifice BryantAltitude Compensation* 04-06 Low NOx Units Troubleshooting Heating SystemMinimum heating entering air temperature Cont. Altitude Compensation* A08-A12Problem Cause Remedy Heating Service AnalysisEconomizer Systems IGC Board LED Alarm CodesEconoMi$er2 Component Locations RUN Inputs OutputsEconoMi$er Supply Air Temperature SAT SensorTemp Resistance EconoMi$er IV Control Modes Outdoor Air Lockout SensorOutdoor Dry Bulb Changeover Outdoor Enthalpy Changeover Differential Enthalpy ControlMinimum Position Control Exhaust Setpoint AdjustmentOccupancy Control CO2 Sensor ConfigurationDamper Movement ThermostatsDifferential Enthalpy DCV Demand Controlled Ventilation and Power ExhaustEconoMi$er IV Sensor Usage EconoMi$er IV PreparationPRE-START-UP Wiring DiagramsPersonal Injury Hazard START-UP, General Operating Sequences Torque Values Fastener Torque ValuesDemand Controlled Ventilation Heating With EconoMi$erC08308 580J Unit Wiring Diagram Control 06A, B, C Position Number Appendix I. Model Number SignificanceModel Number Nomenclature Serial Number FormatPhysical Data Cooling Tons Standard Refrigeration System Appendix II. Physical DataRefrigeration System 580J*08 580J*09 580J*12 Physical Data Cooling 10 Tons Standard Refrigeration SystemPhysical Data Heating 10 Tons General Fan Performance Notes Appendix III. FAN PerformanceCFM RPM BHP 580J*04Ton Horizontal Supply Ton Vertical SupplyMedium Static Option High Static Option 580J*05 580J*05 Phase Ton Horizontal Supply1486 580J*05 Phase Ton Vertical Supply1493 15061482 580J*06580J*06 Phase Ton Vertical Supply 580J*06 Phase Ton Horizontal Supply580J*07 580J*08 580J*09 580J*12 Unit MOTOR/DRIVE Motor Pulley Turns Open Combo Pulley AdjustmentType Appendix IV. Electrical DataIFM Range RLA LRAFLA Appendix IV. Electrical DataRLA LRA 580J*08 Tons580J*09 Tons IFM RangeMCA/MOCP Determination No C.O. or Unpwrd C.O NOM Unbalanced 3-Phase Supply VoltageWiring Diagrams Appendix V. Wiring Diagram List580J*04A, B, C Outdoor Circuiting Appendix VI. Motormaster Sensor LocationsCatalog No. SM580J---01 580J*09/12A, C Outdoor CircuitingElectrical START-UP ChecklistTemperatures Remove and Store in Job File

580J*04--12 specifications

The Bryant 580J*04--12 is a notable unit in the realm of residential air conditioning, exemplifying efficiency and reliability. Designed to offer optimal cooling solutions, this model incorporates advanced technologies and features that cater to modern comfort needs.

One of the standout features of the Bryant 580J is its energy efficiency. With a high Seasonal Energy Efficiency Ratio (SEER) rating, this air conditioning unit is engineered to minimize energy consumption while maximizing cooling performance. This efficiency not only reduces monthly utility bills but also aligns with environmentally friendly practices by using less energy.

The 580J model is equipped with advanced compressor technology, which contributes to its smooth and quiet operation. This is particularly important for residential settings, where noise can be a significant concern. The unit consistently maintains comfortable indoor temperatures without disruptive sound levels, enhancing the overall living experience.

This air conditioning system is designed with durability in mind. Constructed from robust materials, it withstands the rigors of various weather conditions. Additionally, its components are engineered for longevity, reducing the need for frequent repairs and maintenance. The 580J also comes with a comprehensive warranty, which provides homeowners with peace of mind regarding their investment.

Smart technology integration is another key feature of the Bryant 580J. Homeowners can take advantage of programmable thermostats and compatibility with home automation systems. This allows for remote access and control, making it easier to manage indoor climates efficiently. Users can set schedules, adjust temperatures, and monitor energy usage from their smartphones, adding a layer of convenience to everyday living.

Furthermore, the Bryant 580J includes advanced air filtration systems that improve indoor air quality. By effectively trapping dust, allergens, and pollutants, this unit promotes a healthier living environment. This feature is particularly beneficial for individuals with allergies or respiratory issues.

In summary, the Bryant 580J*04--12 stands out for its energy efficiency, quiet operation, durability, smart technology integration, and air quality improvement capabilities. By blending advanced engineering with user-friendly features, this model continues to be a top choice for homeowners seeking reliable and efficient air conditioning solutions.