Bryant 580J*04--12 Puronr R410A Refrigerant, Refrigerant Charge, No Charge, Low-Charge Cooling

Page 8

SEATCORE

(Part No. EC39EZ067)

1/2-20 UNF RH

0.596

30o

WASHER

O-RING

45o

DEPRESSOR PER ARI 720 +.01/-.035

5/8” HEX

.47

1/2" HEX

FROM FACE OF BODY

This surface provides a metal to metal seal when torqued into the seat. Appropriate handling is required to not scratch or dent the surface.

7/16-20 UNF RH

C08453

580J

Fig. 11 - CoreMax Access Port Assembly

PURONR (R410A) REFRIGERANT

This unit is designed for use with Puron (R410A) refrigerant. Do not use any other refrigerant in this system.

Puron (R410A) is provided in pink (rose) colored cylinders. These cylinders are available with and without dip tubes; cylinders with dip tubes will have a label indicating this feature. For a cylinder with a dip tube, place the cylinder in the upright position (access valve at the top) when removing liquid refrigerant for charging. For a cylinder without a dip tube, invert the cylinder (access valve on the bottom) when removing liquid refrigerant.

Because Puron (R410A) is a blend, it is strongly recommended that refrigerant always be removed from the cylinder as a liquid. Admit liquid refrigerant into the system in the discharge line. If adding refrigerant into the suction line, use a commercial metering/expansion device at the gauge manifold; remove liquid from the cylinder, pass it through the metering device at the gauge set and then pass it into the suction line as a vapor. Do not remove Puron (R410A) from the cylinder as a vapor.

Refrigerant Charge

Amount of refrigerant charge is listed on the unit’s nameplate. Refer to GTAC2-5 Charging, Recovery, Recycling and Reclamation training manual and the following procedures.

Unit panels must be in place when unit is operating during the charging procedure.

No Charge

Use standard evacuating techniques. After evacuating system, weigh in the specified amount of refrigerant.

Low-Charge Cooling

Using Cooling Charging Charts, Fig. 12, vary refrigerant until the conditions of the appropriate chart are met. Note the charging charts are different from type normally used. Charts are based on charging the units to the correct superheat for the various operating conditions. Accurate pressure gauge and temperature sensing device are

required. Connect the pressure gauge to the service port on the suction line. Mount the temperature sensing device on the suction line and insulate it so that outdoor ambient temperature does not affect the reading. Indoor-air cfm must be within the normal operating range of the unit.

To Use Cooling Charging Charts

Take the outdoor ambient temperature and read the suction pressure gauge. Refer to chart to determine what suction temperature should be. If suction temperature is high, add refrigerant. If suction temperature is low, carefully recover some of the charge. Recheck the suction pressure as charge is adjusted.

SIZE DESIGNATION

NOMINAL TONS

REFERENCE

 

 

 

04A,B,C

3

05A,B,C

4

 

 

06A,B,C

5

 

 

07A,C

6

 

 

08A,C

7.5

 

 

09A,C

8.5

 

 

12A,C

10

 

 

EXAMPLE:

Model 580J*04A (3 ton)

Outdoor Temperature . . . . . . . . . . . . . . . . . . 85_F (29_C) Suction Pressure . . . . . . . . . . . . . . . . . 140 psig (965 kPa) Suction Temperature should be . . . . . . . . . . 60_F (16_C)

8

Image 8
Contents Table of Contents Safety ConsiderationsUnit Arrangement and Access Routine MaintenanceSeasonal Maintenance GeneralHeating Economizer or Outside Air DamperAir Filters and Screens Return Air FiltersAdjustable-Pitch Pulley on Motor Supply FAN Blower SectionSupply Fan Belt-Drive Electrical Shock HazardCondenser Coil Maintenance and Cleaning Recommendation CoolingCondenser Coil Remove Surface Loaded FibersPeriodic Clean Water Rinse Routine Cleaning of Coil SurfacesOne-Row Coil Two-Row CoilsRefrigerant System Pressure Access Ports Cleaning the Evaporator CoilEvaporator Coil Unit Damage HazardTo Use Cooling Charging Charts Puronr R410A RefrigerantRefrigerant Charge No ChargeCooling Charging Charts Cooling Charging ChartsCooling Charging Charts C08437 C08438 C08439 Troubleshooting Cooling System CompressorFilter Drier Condenser-Fan LocationCooling Service Analysis Problem Cause RemedyConnections Convenience OutletsUnit Connect Primary Transformer Smoke Detectors SystemSensor ControllerCompleting Installation of Return Air Smoke Sensor Smoke Detector LocationsFiop Smoke Detector Wiring and Response Return Air Sensor Operating PositionSensor Alarm Test Controller Alarm TestSensor and Controller Tests Dirty Controller TestRemote Test/Reset Station Dirty Sensor Test Detector CleaningChanging the Dirt Sensor Test Remote Station TestIndicators Detector IndicatorsAlarm State Control or Indicator DescriptionTroubleshooting Protective DevicesCompressor Protection Relief DeviceGAS Heating System Control CircuitFuel Types and Pressures Natural Gas Supply Line Pressure RangesFlue Gas Passageways Combustion-Air BlowerLiquid Propane Supply Line Pressure Ranges Liquid Propane Manifold Pressure RangesRemoval and Replacement of Gas Train Cleaning and AdjustmentBurners and Igniters Equipment Damage HazardBurner Ignition Check Unit Operation and Make Necessary Adjust- mentsLimit Switch Spark Adjustment LED Indication Error Code Description Orifice ReplacementLED Error Code Description Integrated Gas Control IGC Board IGC Connections OutputsOrifice Sizes Altitude Compensation* 04-07 Small ChassisOrifice Bryant Drill Size Part NumberTroubleshooting Heating System Minimum heating entering air temperatureCont. Altitude Compensation* A08-A12 Altitude Compensation* 04-06 Low NOx UnitsHeating Service Analysis Problem Cause RemedyIGC Board LED Alarm Codes Economizer SystemsEconoMi$er2 Component Locations Inputs Outputs RUNTemp Resistance Supply Air Temperature SAT SensorEconoMi$er Outdoor Dry Bulb Changeover Outdoor Air Lockout SensorEconoMi$er IV Control Modes Differential Enthalpy Control Outdoor Enthalpy ChangeoverExhaust Setpoint Adjustment Minimum Position ControlCO2 Sensor Configuration Damper MovementThermostats Occupancy ControlDCV Demand Controlled Ventilation and Power Exhaust EconoMi$er IV Sensor UsageEconoMi$er IV Preparation Differential EnthalpyPersonal Injury Hazard Wiring DiagramsPRE-START-UP START-UP, General Operating Sequences Fastener Torque Values Demand Controlled VentilationHeating With EconoMi$er Torque ValuesC08308 580J Unit Wiring Diagram Control 06A, B, C Appendix I. Model Number Significance Model Number NomenclatureSerial Number Format Position NumberAppendix II. Physical Data Physical Data Cooling Tons Standard Refrigeration SystemPhysical Data Cooling 10 Tons Standard Refrigeration System Refrigeration System 580J*08 580J*09 580J*12Physical Data Heating 10 Tons Appendix III. FAN Performance General Fan Performance Notes580J*04 Ton Horizontal SupplyTon Vertical Supply CFM RPM BHPMedium Static Option High Static Option 580J*05 Phase Ton Horizontal Supply 580J*05580J*05 Phase Ton Vertical Supply 14931506 1486580J*06 1482580J*06 Phase Ton Horizontal Supply 580J*06 Phase Ton Vertical Supply580J*07 580J*08 580J*09 580J*12 Pulley Adjustment Unit MOTOR/DRIVE Motor Pulley Turns Open ComboAppendix IV. Electrical Data IFMRange RLA LRA TypeAppendix IV. Electrical Data FLA580J*08 Tons 580J*09 TonsIFM Range RLA LRAMCA/MOCP Determination No C.O. or Unpwrd C.O Unbalanced 3-Phase Supply Voltage NOMAppendix V. Wiring Diagram List Wiring DiagramsAppendix VI. Motormaster Sensor Locations 580J*04A, B, C Outdoor Circuiting580J*09/12A, C Outdoor Circuiting Catalog No. SM580J---01START-UP Checklist TemperaturesRemove and Store in Job File Electrical

580J*04--12 specifications

The Bryant 580J*04--12 is a notable unit in the realm of residential air conditioning, exemplifying efficiency and reliability. Designed to offer optimal cooling solutions, this model incorporates advanced technologies and features that cater to modern comfort needs.

One of the standout features of the Bryant 580J is its energy efficiency. With a high Seasonal Energy Efficiency Ratio (SEER) rating, this air conditioning unit is engineered to minimize energy consumption while maximizing cooling performance. This efficiency not only reduces monthly utility bills but also aligns with environmentally friendly practices by using less energy.

The 580J model is equipped with advanced compressor technology, which contributes to its smooth and quiet operation. This is particularly important for residential settings, where noise can be a significant concern. The unit consistently maintains comfortable indoor temperatures without disruptive sound levels, enhancing the overall living experience.

This air conditioning system is designed with durability in mind. Constructed from robust materials, it withstands the rigors of various weather conditions. Additionally, its components are engineered for longevity, reducing the need for frequent repairs and maintenance. The 580J also comes with a comprehensive warranty, which provides homeowners with peace of mind regarding their investment.

Smart technology integration is another key feature of the Bryant 580J. Homeowners can take advantage of programmable thermostats and compatibility with home automation systems. This allows for remote access and control, making it easier to manage indoor climates efficiently. Users can set schedules, adjust temperatures, and monitor energy usage from their smartphones, adding a layer of convenience to everyday living.

Furthermore, the Bryant 580J includes advanced air filtration systems that improve indoor air quality. By effectively trapping dust, allergens, and pollutants, this unit promotes a healthier living environment. This feature is particularly beneficial for individuals with allergies or respiratory issues.

In summary, the Bryant 580J*04--12 stands out for its energy efficiency, quiet operation, durability, smart technology integration, and air quality improvement capabilities. By blending advanced engineering with user-friendly features, this model continues to be a top choice for homeowners seeking reliable and efficient air conditioning solutions.