Bryant 580J*04--12 appendix Pulley Adjustment, Unit MOTOR/DRIVE Motor Pulley Turns Open Combo

Page 64

580J

APPENDIX III. FAN PERFORMANCE (cont.)

Pulley Adjustment

UNIT

MOTOR/DRIVE

 

 

 

MOTOR PULLEY TURNS OPEN

 

 

 

COMBO

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

4.5

5.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

phase1

Standard Static

854

825

795

766

736

707

678

648

619

589

560

 

Medium Static

1175

1135

1094

1054

1013

973

932

892

851

811

770

 

 

04

 

High Static

---

---

---

---

---

---

---

---

---

---

---

 

 

 

 

 

 

 

 

 

 

 

 

 

phase3

Standard Static

854

825

795

766

736

707

678

648

619

589

560

 

 

Medium Static

1175

1135

1094

1054

1013

973

932

892

851

811

770

 

 

 

 

High Static

1466

1423

1380

1337

1294

1251

1207

1164

1121

1078

1035

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

phase1

Standard Static

854

825

795

766

736

707

678

648

619

589

560

 

Medium Static

1175

1135

1094

1054

1013

973

932

892

851

811

770

 

 

05

 

High Static

---

---

---

---

---

---

---

---

---

---

---

 

 

 

 

 

 

 

 

 

 

 

 

 

phase3

Standard Static

854

825

795

766

736

707

678

648

619

589

560

 

 

Medium Static

1175

1135

1094

1054

1013

973

932

892

851

811

770

 

 

 

 

High Static

1466

1423

1380

1337

1294

1251

1207

1164

1121

1078

1035

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

phase1

Standard Static

1175

1135

1094

1054

1013

973

932

892

851

811

770

 

Medium Static

1466

1423

1380

1337

1294

1251

1207

1164

1121

1078

1035

 

 

06

 

High Static

---

---

---

---

---

---

---

---

---

---

---

 

 

 

 

 

 

 

 

 

 

 

 

 

phase3

Standard Static

1175

1135

1094

1054

1013

973

932

892

851

811

770

 

 

Medium Static

1466

1423

1380

1337

1294

1251

1207

1164

1121

1078

1035

 

 

 

 

High Static

1687

1649

1610

1572

1533

1495

1457

1418

1380

1341

1303

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

phase

Standard Static

1457

1419

1380

1342

1303

1265

1227

1188

1150

1111

1073

07

Medium Static

1518

1484

1449

1415

1380

1346

1311

1277

1242

1208

1173

 

 

 

3

High Static

1788

1757

1725

1694

1662

1631

1600

1568

1537

1505

1474

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

phase

Standard Static

747

721

695

670

644

618

592

566

541

515

489

08

Medium Static

949

927

906

884

863

841

819

798

776

755

733

 

 

 

3

High Static

1102

1083

1063

1044

1025

1006

986

967

948

928

909

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

phase

Standard Static

733

712

690

669

647

626

604

583

561

540

518

09

Medium Static

936

911

887

862

838

813

788

764

739

715

690

 

 

 

3

High Static

1084

1059

1035

1010

986

961

936

912

887

863

838

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

phase

Standard Static

838

813

789

764

739

715

690

665

640

616

591

12

Medium Static

1084

1059

1035

1010

986

961

936

912

887

863

838

 

 

 

3

High Static

1240

1218

1196

1175

1153

1131

1109

1087

1066

1044

1022

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: Do not adjust pulley further than 5 turns open.

--- Factory settings

64

Image 64
Contents Table of Contents Safety ConsiderationsUnit Arrangement and Access Routine MaintenanceSeasonal Maintenance GeneralHeating Economizer or Outside Air DamperAir Filters and Screens Return Air FiltersAdjustable-Pitch Pulley on Motor Supply FAN Blower SectionSupply Fan Belt-Drive Electrical Shock HazardCondenser Coil Maintenance and Cleaning Recommendation CoolingCondenser Coil Remove Surface Loaded FibersPeriodic Clean Water Rinse Routine Cleaning of Coil SurfacesOne-Row Coil Two-Row CoilsRefrigerant System Pressure Access Ports Cleaning the Evaporator CoilEvaporator Coil Unit Damage HazardTo Use Cooling Charging Charts Puronr R410A RefrigerantRefrigerant Charge No ChargeCooling Charging Charts Cooling Charging ChartsCooling Charging Charts C08437 C08438 C08439 Troubleshooting Cooling System CompressorFilter Drier Condenser-Fan LocationCooling Service Analysis Problem Cause RemedyUnit Connect Primary Transformer Convenience OutletsConnections Smoke Detectors SystemSensor ControllerCompleting Installation of Return Air Smoke Sensor Smoke Detector LocationsFiop Smoke Detector Wiring and Response Return Air Sensor Operating PositionSensor Alarm Test Controller Alarm TestSensor and Controller Tests Dirty Controller TestRemote Test/Reset Station Dirty Sensor Test Detector CleaningChanging the Dirt Sensor Test Remote Station TestIndicators Detector IndicatorsAlarm State Control or Indicator DescriptionTroubleshooting Protective DevicesCompressor Protection Relief DeviceGAS Heating System Control CircuitFuel Types and Pressures Natural Gas Supply Line Pressure RangesFlue Gas Passageways Combustion-Air BlowerLiquid Propane Supply Line Pressure Ranges Liquid Propane Manifold Pressure RangesRemoval and Replacement of Gas Train Cleaning and AdjustmentBurners and Igniters Equipment Damage HazardLimit Switch Check Unit Operation and Make Necessary Adjust- mentsBurner Ignition Spark Adjustment LED Error Code Description Orifice ReplacementLED Indication Error Code Description Integrated Gas Control IGC Board IGC Connections OutputsOrifice Sizes Altitude Compensation* 04-07 Small ChassisOrifice Bryant Drill Size Part NumberTroubleshooting Heating System Minimum heating entering air temperatureCont. Altitude Compensation* A08-A12 Altitude Compensation* 04-06 Low NOx UnitsHeating Service Analysis Problem Cause RemedyIGC Board LED Alarm Codes Economizer SystemsEconoMi$er2 Component Locations Inputs Outputs RUNEconoMi$er Supply Air Temperature SAT SensorTemp Resistance EconoMi$er IV Control Modes Outdoor Air Lockout SensorOutdoor Dry Bulb Changeover Differential Enthalpy Control Outdoor Enthalpy ChangeoverExhaust Setpoint Adjustment Minimum Position ControlCO2 Sensor Configuration Damper MovementThermostats Occupancy ControlDCV Demand Controlled Ventilation and Power Exhaust EconoMi$er IV Sensor UsageEconoMi$er IV Preparation Differential EnthalpyPRE-START-UP Wiring DiagramsPersonal Injury Hazard START-UP, General Operating Sequences Fastener Torque Values Demand Controlled VentilationHeating With EconoMi$er Torque ValuesC08308 580J Unit Wiring Diagram Control 06A, B, C Appendix I. Model Number Significance Model Number NomenclatureSerial Number Format Position NumberAppendix II. Physical Data Physical Data Cooling Tons Standard Refrigeration SystemPhysical Data Cooling 10 Tons Standard Refrigeration System Refrigeration System 580J*08 580J*09 580J*12Physical Data Heating 10 Tons Appendix III. FAN Performance General Fan Performance Notes580J*04 Ton Horizontal SupplyTon Vertical Supply CFM RPM BHPMedium Static Option High Static Option 580J*05 Phase Ton Horizontal Supply 580J*05580J*05 Phase Ton Vertical Supply 14931506 1486580J*06 1482580J*06 Phase Ton Horizontal Supply 580J*06 Phase Ton Vertical Supply580J*07 580J*08 580J*09 580J*12 Pulley Adjustment Unit MOTOR/DRIVE Motor Pulley Turns Open ComboAppendix IV. Electrical Data IFMRange RLA LRA TypeAppendix IV. Electrical Data FLA580J*08 Tons 580J*09 TonsIFM Range RLA LRAMCA/MOCP Determination No C.O. or Unpwrd C.O Unbalanced 3-Phase Supply Voltage NOMAppendix V. Wiring Diagram List Wiring DiagramsAppendix VI. Motormaster Sensor Locations 580J*04A, B, C Outdoor Circuiting580J*09/12A, C Outdoor Circuiting Catalog No. SM580J---01START-UP Checklist TemperaturesRemove and Store in Job File Electrical

580J*04--12 specifications

The Bryant 580J*04--12 is a notable unit in the realm of residential air conditioning, exemplifying efficiency and reliability. Designed to offer optimal cooling solutions, this model incorporates advanced technologies and features that cater to modern comfort needs.

One of the standout features of the Bryant 580J is its energy efficiency. With a high Seasonal Energy Efficiency Ratio (SEER) rating, this air conditioning unit is engineered to minimize energy consumption while maximizing cooling performance. This efficiency not only reduces monthly utility bills but also aligns with environmentally friendly practices by using less energy.

The 580J model is equipped with advanced compressor technology, which contributes to its smooth and quiet operation. This is particularly important for residential settings, where noise can be a significant concern. The unit consistently maintains comfortable indoor temperatures without disruptive sound levels, enhancing the overall living experience.

This air conditioning system is designed with durability in mind. Constructed from robust materials, it withstands the rigors of various weather conditions. Additionally, its components are engineered for longevity, reducing the need for frequent repairs and maintenance. The 580J also comes with a comprehensive warranty, which provides homeowners with peace of mind regarding their investment.

Smart technology integration is another key feature of the Bryant 580J. Homeowners can take advantage of programmable thermostats and compatibility with home automation systems. This allows for remote access and control, making it easier to manage indoor climates efficiently. Users can set schedules, adjust temperatures, and monitor energy usage from their smartphones, adding a layer of convenience to everyday living.

Furthermore, the Bryant 580J includes advanced air filtration systems that improve indoor air quality. By effectively trapping dust, allergens, and pollutants, this unit promotes a healthier living environment. This feature is particularly beneficial for individuals with allergies or respiratory issues.

In summary, the Bryant 580J*04--12 stands out for its energy efficiency, quiet operation, durability, smart technology integration, and air quality improvement capabilities. By blending advanced engineering with user-friendly features, this model continues to be a top choice for homeowners seeking reliable and efficient air conditioning solutions.