SECTION 2: POWER SUPPLY

Availability

Before installing the machine, consider the avail- ability and proximity of the required power supply circuit. If an existing circuit does not meet the requirements for this machine, a new circuit must be installed. To minimize the risk of electrocu- tion, fire, or equipment damage, installation work and electrical wiring must be done by a qualified electrician in accordance with all applicable codes and standards.

Electrocution, fire, or equipment damage may occur if machine is not correctly grounded and connected to the power supply.

Full-Load Current Rating

The full-load current rating is the amperage a machine draws at 100% of the rated output power. On machines with multiple motors, this is the amperage drawn by the largest motor or sum of all motors and electrical devices that might operate at one time during normal operations.

Full-Load Current Rating at 110V

11

Amps

Full-Load Current Rating at 220V

5.5

Amps

The full-load current is not the maximum amount of amps that the machine will draw. If the machine is overloaded, it will draw additional amps beyond the full-load rating.

If the machine is overloaded for a sufficient length of time, damage, overheating, or fire may result— especially if connected to an undersized circuit. To reduce the risk of these hazards, avoid over- loading the machine during operation and make sure it is connected to a power supply circuit that meets the requirements in the following section.

Model G0555/G0555P (Mfg. Since 5/11)

Circuit Information

A power supply circuit includes all electrical equipment between the breaker box or fuse panel in the building and the machine. The power sup- ply circuit used for this machine must be sized to safely handle the full-load current drawn from the machine for an extended period of time. (If this machine is connected to a circuit protected by fuses, use a time delay fuse marked D.)

For your own safety and protection of property, consult a qualified electrician if you are unsure about wiring practices or electrical codes in your area.

Note: The circuit requirements listed in this man- ual apply to a dedicated circuit—where only one machine will be running at a time. If this machine will be connected to a shared circuit where mul- tiple machines will be running at the same time, consult a qualified electrician to ensure that the circuit is properly sized for safe operation.

Circuit Requirements for 110V

This machine is prewired to operate on a 110V power supply circuit that has a verified ground and meets the following requirements:

Nominal Voltage

110V/120V

Cycle

60 Hz

Phase

Single-Phase

Circuit Rating

15 Amps

Plug/Receptacle

NEMA 5-15

Circuit Requirements for 220V

This machine can be converted to operate on a 220V power supply (refer to Voltage Conversion instructions). This power supply must have a veri- fied ground and meet the following requirements:

Nominal Voltage

220V/240V

Cycle

60 Hz

Phase

Single-Phase

Circuit Rating

15 Amps

Plug/Receptacle

NEMA 6-15

 

-9-

Image 11
Contents Ultimate 14 Bandsaw Page Table of Contents Machine Description IntroductionManual Accuracy Contact Info Identification MaCHiNe data SHeet Table Information Safety Instructions for Machinery SafetyPage Additional Safety for Bandsaws Circuit Information Power SupplyAvailability Full-Load Current RatingShock Hazard Grounding Requirements50 ft Extension CordsVoltage Conversion Minimum Gauge Size 14 AWGDescription Qty SetupNeeded for Setup UnpackingHardware Recognition Chart Shipping Inventory Figures Qty InventoryBasic steps for removing rust preventative CleanupBefore cleaning, gather the following Site Considerations Ing the stand easier in a later step AssemblyLeveling the stand Trunnion Page Fence stand-off installed Model G0555/G0555P Mfg. Since 5/11 To center track the blade Blade Center TrackingTo connect a dust collection hose Dust CollectionTo test run the machine Power Connection Test RunConnecting Power Disconnecting PowerTo tension the bandsaw blade Tensioning BladeTo adjust the support bearings Adjusting Blade Support BearingsTool Needed Qty Adjusting Blade Guide BearingsTo adjust the upper and lower blade guides Page To set the positive stop 90˚ to the blade Table Tilt CalibrationTools Needed Qty Step Aligning TableTo align the table to the blade Aligning Fence Operation Overview OperationsBefore cutting, inspect all workpieces for the following Disabling & Locking SwitchWorkpiece Inspection To tilt the table To adjust the height of the guide postGuide Post Table Tilt To change the blade speed Blade SpeedBlade Width Blade DimensionsBlade Information Blade LengthMost common causes of blade breakage are Tooth PitchBlade Care Blade BreakageBlade Removal Blade InstallationBlade Change To make a rip cut Basic Cutting TipsCutting Options RippingTo make a 90˚ crosscut CrosscuttingResawingTo complete a stacked cut Cutting Curves Stacked CutsG1928-Bandsaw Handbook AccessoriesBandsaw Blades ModelH7584-Re-Saw Fence Retrofit Kit G7315Z-Super Heavy-Duty Shop FOX Mobile BaseDaily MaintenanceCleaning Protecting ScheduleTo redress the rubber tires LubricationRedressing Rubber Tires Motor & Electrical ServiceTroubleshooting Miscellaneous Cutting OperationsTo properly tension the V-belt Belt TensionChecking V-Belt Tension Tensioning V-BeltBelt Tension subsection on Replacing V-BeltShimming Table To replace the V-beltChecking Wheel Alignment Wheel AlignmentTo shim a wheel Shimming a WheelTo adjust the upper wheel laterally Upper Wheel Lateral AdjustmentTo shift the table Blade LeadTo correct blade lead To skew your fenceBlade Tensioner To reset the blade tensionerTo calibrate the scale Fence Scale CalibrationWiring Safety Instructions Wiring110 VAC Wiring DiagramMain Description Main Parts ListDescription Stand Fence 144V2 216 155 145 148 147 149 157 156 218 217 214 LabelsComments Warranty CardBOX BELLINGHAM, WA Grizzly INDUSTRIAL, INCWarranty and Returns Warranty and ReturnsOrder Hours a DAY