Grizzly G0555 owner manual Extension Cords, Voltage Conversion, Minimum Gauge Size 14 AWG, 50 ft

Page 13

Extension Cords

We do not recommend using an extension cord with this machine. If you must use an extension cord, only use it if absolutely necessary and only on a temporary basis.

Extension cords cause voltage drop, which may damage electrical components and shorten motor life. Voltage drop increases as the extension cord size gets longer and the gauge size gets smaller (higher gauge numbers indicate smaller sizes).

Any extension cord used with this machine must contain a ground wire, match the required plug and receptacle, and meet the following require- ments:

Minimum Gauge Size

14 AWG

Maximum Length (Shorter is Better)

50 ft.

Model G0555/G0555P (Mfg. Since 5/11)

Voltage Conversion

The voltage conversion MUST be performed by a electrician or qualified service personnel. To perform the voltage conversion, install the cor- rect plug and rewire the motor to the new volt- age, according to the provided wiring diagram on Page 56.

Note: If the diagram included on the motor con- flicts with the one in this manual, the motor may have changed since the manual was printed. Use the diagram provided inside the motor wiring junc- tion box.

To convert the machine to 220V:

1.DISCONNECT MACHINE FROM POWER!

2.Replace the 5-15 plug on the power cord with a 6-15 plug.

3.Re-wire the motor as illustrated in the wiring diagram.

-11-

Image 13
Contents Ultimate 14 Bandsaw Page Table of Contents Manual Accuracy Contact Info IntroductionMachine Description Identification MaCHiNe data SHeet Table Information Safety Instructions for Machinery SafetyPage Additional Safety for Bandsaws Availability Power SupplyFull-Load Current Rating Circuit InformationShock Hazard Grounding RequirementsVoltage Conversion Extension CordsMinimum Gauge Size 14 AWG 50 ftNeeded for Setup SetupUnpacking Description QtyHardware Recognition Chart Shipping Inventory Figures Qty InventoryBefore cleaning, gather the following CleanupBasic steps for removing rust preventative Site Considerations Ing the stand easier in a later step AssemblyLeveling the stand Trunnion Page Fence stand-off installed Model G0555/G0555P Mfg. Since 5/11 To center track the blade Blade Center TrackingTo connect a dust collection hose Dust CollectionConnecting Power Power Connection Test RunDisconnecting Power To test run the machineTo tension the bandsaw blade Tensioning BladeTo adjust the support bearings Adjusting Blade Support BearingsTo adjust the upper and lower blade guides Adjusting Blade Guide BearingsTool Needed Qty Page Tools Needed Qty Table Tilt CalibrationTo set the positive stop 90˚ to the blade To align the table to the blade Aligning TableStep Aligning Fence Operation Overview OperationsWorkpiece Inspection Disabling & Locking SwitchBefore cutting, inspect all workpieces for the following Guide Post Table Tilt To adjust the height of the guide postTo tilt the table To change the blade speed Blade SpeedBlade Information Blade DimensionsBlade Length Blade WidthBlade Care Tooth PitchBlade Breakage Most common causes of blade breakage areBlade Change Blade InstallationBlade Removal Cutting Options Basic Cutting TipsRipping To make a rip cutTo make a 90˚ crosscut CrosscuttingResawingTo complete a stacked cut Cutting Curves Stacked CutsBandsaw Blades AccessoriesModel G1928-Bandsaw HandbookH7584-Re-Saw Fence Retrofit Kit G7315Z-Super Heavy-Duty Shop FOX Mobile BaseCleaning Protecting MaintenanceSchedule DailyRedressing Rubber Tires LubricationTo redress the rubber tires Troubleshooting ServiceMotor & Electrical Miscellaneous Cutting OperationsChecking V-Belt Tension Belt TensionTensioning V-Belt To properly tension the V-beltShimming Table Replacing V-BeltTo replace the V-belt Belt Tension subsection onChecking Wheel Alignment Wheel AlignmentTo shim a wheel Shimming a WheelTo adjust the upper wheel laterally Upper Wheel Lateral AdjustmentTo correct blade lead Blade LeadTo skew your fence To shift the tableBlade Tensioner To reset the blade tensionerTo calibrate the scale Fence Scale CalibrationWiring Safety Instructions Wiring110 VAC Wiring DiagramMain Description Main Parts ListDescription Stand Fence 144V2 216 155 145 148 147 149 157 156 218 217 214 LabelsComments Warranty CardBOX BELLINGHAM, WA Grizzly INDUSTRIAL, INCWarranty and Returns Warranty and ReturnsOrder Hours a DAY