Grizzly G0555 owner manual Power Connection Test Run, Connecting Power, Disconnecting Power

Page 25

Power Connection

 

Test Run

 

 

 

 

 

 

After you have completed all previous setup instructions and circuit requirements, the machine is ready to be connected to the power supply.

To avoid unexpected startups or property dam- age, use the following steps whenever connecting or disconnecting the machine.

Connecting Power

1.Turn the machine power switch OFF.

2.Insert the power cord plug into a matching power supply receptacle. The machine is now connected to the power source.

Figure 25. Connecting power.

Disconnecting Power

1.Turn the machine power switch OFF.

2.Grasp the molded plug and pull it completely out of the receptacle. Do not pull by the cord as this may damage the wires inside.

Figure 26. Disconnecting power.

Model G0555/G0555P (Mfg. Since 5/11)

Once the assembly is complete, test run your machine to make sure it runs properly and is ready for regular operation.

The test run consists of verifying the following:

1)The motor powers up and runs correctly, and

2)the safety disabling mechanism on the switch works correctly.

If, during the test run, you cannot easily locate the source of an unusual noise or vibration, stop using the machine immediately, then review Troubleshooting on Page 45.

If you still cannot remedy a problem, contact our Tech Support at (570) 546-9663 for assistance.

To test run the machine:

1.Make sure you have read the safety instruc- tions at the beginning of the manual and that the machine is set up properly.

2.Make sure all tools and objects used during setup are cleared away from the machine.

3.Verify that the machine is operating correctly by turning it ON.

—When operating correctly, the machine runs smoothly with little or no vibration or rubbing noises.

—Investigate and correct strange or unusual noises or vibrations before operating the machine further. Always disconnect the machine from power when investigating or correcting potential problems.

-23-

Image 25
Contents Ultimate 14 Bandsaw Page Table of Contents Manual Accuracy Contact Info IntroductionMachine Description Identification MaCHiNe data SHeet Table Information Safety Instructions for Machinery SafetyPage Additional Safety for Bandsaws Availability Power SupplyFull-Load Current Rating Circuit InformationShock Hazard Grounding RequirementsVoltage Conversion Extension CordsMinimum Gauge Size 14 AWG 50 ftNeeded for Setup SetupUnpacking Description QtyHardware Recognition Chart Shipping Inventory Figures Qty InventoryBefore cleaning, gather the following CleanupBasic steps for removing rust preventative Site Considerations Ing the stand easier in a later step AssemblyLeveling the stand Trunnion Page Fence stand-off installed Model G0555/G0555P Mfg. Since 5/11 To center track the blade Blade Center TrackingTo connect a dust collection hose Dust CollectionConnecting Power Power Connection Test RunDisconnecting Power To test run the machineTo tension the bandsaw blade Tensioning BladeTo adjust the support bearings Adjusting Blade Support BearingsTo adjust the upper and lower blade guides Adjusting Blade Guide BearingsTool Needed Qty Page Tools Needed Qty Table Tilt CalibrationTo set the positive stop 90˚ to the blade To align the table to the blade Aligning TableStep Aligning Fence Operation Overview OperationsWorkpiece Inspection Disabling & Locking SwitchBefore cutting, inspect all workpieces for the following Guide Post Table Tilt To adjust the height of the guide postTo tilt the table To change the blade speed Blade SpeedBlade Information Blade DimensionsBlade Length Blade WidthBlade Care Tooth PitchBlade Breakage Most common causes of blade breakage areBlade Change Blade InstallationBlade Removal Cutting Options Basic Cutting TipsRipping To make a rip cutTo make a 90˚ crosscut CrosscuttingResawingTo complete a stacked cut Cutting Curves Stacked CutsBandsaw Blades AccessoriesModel G1928-Bandsaw HandbookH7584-Re-Saw Fence Retrofit Kit G7315Z-Super Heavy-Duty Shop FOX Mobile BaseCleaning Protecting MaintenanceSchedule DailyRedressing Rubber Tires LubricationTo redress the rubber tires Troubleshooting ServiceMotor & Electrical Miscellaneous Cutting OperationsChecking V-Belt Tension Belt TensionTensioning V-Belt To properly tension the V-beltShimming Table Replacing V-BeltTo replace the V-belt Belt Tension subsection onChecking Wheel Alignment Wheel AlignmentTo shim a wheel Shimming a WheelTo adjust the upper wheel laterally Upper Wheel Lateral AdjustmentTo correct blade lead Blade LeadTo skew your fence To shift the tableBlade Tensioner To reset the blade tensionerTo calibrate the scale Fence Scale CalibrationWiring Safety Instructions Wiring110 VAC Wiring DiagramMain Description Main Parts ListDescription Stand Fence 144V2 216 155 145 148 147 149 157 156 218 217 214 LabelsComments Warranty CardBOX BELLINGHAM, WA Grizzly INDUSTRIAL, INCWarranty and Returns Warranty and ReturnsOrder Hours a DAY
Related manuals
Manual 55 pages 21 Kb