Changing Rolling-
Filter Timing
As the
Exhausting Time: This is the time interval between the filter advance events. The time inter- vals can be set at 30, 45, 60, 120, 180, and 240 minutes. For example, if 45 minutes is selected, the filter will advance every 45 minutes for the duration you have selected below under FILTER ROLLING TIME.
Filter Rolling Time: This is the time duration the filter is allowed to advance, which exposes new filter paper. The advance time can be set at 10, 15, 20, 25, 30 or 40 seconds. For example, the greater the filter rolling time, the more fresh filter paper is exposed.
To change the rolling-filter timing:
1.Stop the machine.
2.Refer to the Rolling Filter Consumption Chart on Page 21 to select your needed time values.
3.Open the control panel door (Figure 10).
4.Slide the NOR/SET switch (Figure 10) to the SET position.