Operation
Symptom | Possible Cause | Possible Solution | ||
Suction CFM is | 1. | Blast gate is leaking or is not completely | 1. | Make sure appropriate blast gate(s) are completely |
lower than normal. |
| open. |
| open and do not leak. |
| 2. | Door or cabinet is at fault. | 2. | Make sure that all doors are closed seals do not |
|
|
|
| leak. |
| 3. | Ducting is at fault. | 3. | Reduce length of ducting; maintain 6" diameter |
|
|
|
| ducting; eliminate as many bends as possible; |
|
|
|
| move downdraft table closer to fume extractor. |
| 4. | Slag screen is at fault. | 4. | Remove slag drawer and clean slag screen. |
| 5. | Rolling filter is at fault. | 5. | Increase |
|
|
|
| new filter paper more often to maintain CFM. |
| 6. | Vibrating filter is at fault. | 6. | Manually clean the vibrating filter or replace. |
| 7. | HEPA filter is at fault. | 7. | Manually clean the HEPA filter or replace. |
| 8. | Fan system is at fault. | 8. | Fan motor has lost RPM, adjust/troubleshoot |
|
|
|
| frequency drive and replace motor or frequency |
|
|
|
| drive if required. |
|
|
|
|
|
Filter warning lamp/ | 1. | Infrared sensor is at fault. | 1. | Replace infrared sensor. |
buzzer engages but | 2. | Circuit board is at fault. | 2. | Replace circuit board. |
filter paper has not |
|
|
|
|
run out. |
|
|
|
|
|
|
|
|
|
High | 1. | Incorrect machine usage. | 1. | Eliminate idle time. Do not let machine run between |
usage. |
|
|
| welding jobs, shift changes, or breaks. |
| 2. | Rolling filter advance timing at fault. | 2. | Clean all filters. Delay |
|
|
|
| and/or decrease amount of new filter that is |
|
|
|
| exposed during advance cycles. |
| 3. | Workpiece is not properly prepared. | 3. | Reduce smoke and fumes. Grind, scrape, strip or |
|
|
|
| sandblast away workpiece coatings to a minimum |
|
|
|
| of 4" away from location to be heated. |
|
|
|
|
|
G0648 Welding Fume Extractor |