6.1 Introduction

The following procedures assume that your MultiMuxes (local and remote) have been installed properly (refer to Chapter 4) and the appropriate channel devices have been connected to each channel.

6.2

MultiMuxOperatingProcedures

The MultiMux operating procedures cover entering parameters for both your local and remote MultiMux units.

Table 6-1. MultiMux Operating Procedures

StepProcedure

1Turn power on to your MultiMux and supervisory console, type AT and then hit Return. If you get an OK message back, you are communicating with the command port.

2Execute the parameter display command to display current channel parameter status for your local MultiMux by entering the following:

ATL (hit Return)

The following will be displayed on your supervisory console:

 

 

 

 

 

Local Channel Parameters/ Node # 00

 

 

 

 

 

 

STP

FLOW

ENQ/

 

 

PASS PASS DEST DEST LINK

CHN

SPD WD BIT PAR

CTRL

ACK ECHO PACE

EIA

XON

CHN NODE A/B

01

19200

8

1

NONE

XON/XOFF

OFF

OFF

OFF

OFF

OFF

01

01

A

02

19200

8

1

NONE

XON/XOFF

OFF

OFF

OFF

OFF

OFF

02

01

A

03

19200

8

1

NONE

XON/XOFF

OFF

OFF

OFF

OFF

OFF

03

01

A

04

19200

8

1

NONE

XON/XOFF

OFF

OFF

OFF

OFF

OFF

04

01

A

05

19200

8

1

NONE

XON/XOFF

OFF

OFF

OFF

OFF

OFF

05

01

A

06

19200

8

1

NONE

XON/XOFF

OFF

OFF

OFF

OFF

OFF

06

01

A

07

19200

8

1

NONE

XON/XOFF

OFF

OFF

OFF

OFF

OFF

07

01

A

08

19200

8

1

NONE

XON/XOFF

OFF

OFF

OFF

OFF

OFF

08

01

A

09

19200

8

1

NONE

XON/XOFF

OFF

OFF

OFF

OFF

OFF

09

01

A

10

19200

8

1

NONE

XON/XOFF

OFF

OFF

OFF

OFF

OFF

10

01

A

11

19200

8

1

NONE

XON/XOFF

OFF

OFF

OFF

OFF

OFF

11

01

A

12

19200

8

1

NONE

XON/XOFF

OFF

OFF

OFF

OFF

OFF

12

01

A

13

19200

8

1

NONE

XON/XOFF

OFF

OFF

OFF

OFF

OFF

13

01

A

14

19200

8

1

NONE

XON/XOFF

OFF

OFF

OFF

OFF

OFF

14

01

A

15

19200

8

1

NONE

XON/XOFF

OFF

OFF

OFF

OFF

OFF

15

01

A

16

19200

8

1

NONE

XON/XOFF

OFF

OFF

OFF

OFF

OFF

16

01

A

OK

Table 6-1. MultiMux Operating Procedures (cont.)

StepProcedure

3To reconfigure the channel parameters to match your actual channel requirements enter commands as described in Chapter 5 of this manual.

4If you change operational parameters they are not incorporated into your running system until you execute a Store New Parameters (&W) command:

AT&W (hit Return)

The parameters will be stored in non-volatile memory and become effective immediately. When power is turned off, the parameters will be saved.

5If you wish to display the composite link status, execute the List Composite Link Configuration command by entering the following:

AT$L (hit Return)

The following will be displayed on your system monitor if your MultiMux is configured with an internal composite link DSU on links A and B:

Configuration of Port A: Composite Link

DSU TYPE SPEED CLLCKINGLOOPBACK

EXTERNAL 128K INTERNAL OFF

Configuration of Port B: Composite Link

DSU TYPE SPEED CLOCKINGLOOPBACK

EXTERNAL 128K INTERNAL OFF

Page 59
Image 59
Multi-Tech Systems MMV1600 owner manual MultiMuxOperatingProcedures, MultiMux Operating Procedures