Store New

The

Store

New

Parameters

command

causes

the

MultiMux

to

Parameters

store

new

parameters.

Prior

to

executing

the

&W

command,

 

changes

to

MultiMux

parameters

are

temporary

and

do

not

&W

affect the unit’s operation until you execute the &W command.

The &W command

stores the parameters in nonvolatile memory

and will takes affect immediately.

 

 

 

 

Help

The Help commands are designed to give you short explanations

 

 

 

 

 

on

how

to

use MultiMux commands. They will

be

useful

if

your

H

manual is not handy, although the explanations are quite short

 

 

 

 

H1-H7

in

comparison

to

those

in the

manual.

When a

Help

command

 

is executed in conjunction with some other command, the

 

 

 

 

 

 

resulting display will explain options and information for that

 

command. The General

Help command provides information

 

on the other MultiMux

Help commands.

 

 

 

 

 

 

 

The H command menu is as follows:

 

 

 

 

 

 

 

 

 

 

General Help

 

 

 

 

 

 

 

1. Each command line must begin with the prefix AT.

 

 

 

 

 

 

 

2.

Each command line may contain any number of commands up

 

to 40 characters total.

 

3. Most command letters must be followed by a value.

 

 

 

 

 

 

 

4. For help on specific commands, enter "ATH" followed by the

command letters.

 

 

 

5.For additional help menus, enter "ATH" followed by numbers 1-7.

A.Type ATH or ATH0 for General Help.

B.Type ATH1 for channel parameter commands.

C.Type ATH2 to view the DIP switch configuration.

D.Type ATH3 for composite link speed and clocking commands.

E.Type ATH4 for additional composite link commands.

F.Type ATH5 for miscellaneous commands.

G.Type ATH6 for voice/fax channel commands.

H.Type ATH7 for additional voice/fax channel commands.

The H1 menu is as follows:

CHANNEL PARAMETER COMMANDS

B

-

BAUD RATE SELECTION

P

-

PARITY SELECTION

 

C

-

CHANNEL SELECTION

R

-

RESPONSE TIME PRIORITY

 

DC

-

DEST. CHANNEL SELECTION

SB

-

STOP BIT SELECTION

 

DN

-

DEST. NODE SELECTION

SN

-

LOCAL SOURCE NODE NUMBER

 

E

-

LOCAL ECHO

SNGA..H -

DOWNLINE LOAD SOURCE NODE NUMBER

 

F

-

FLOW CONTROL

#S

-

CHANNEL STATISTICS

 

&F

-

READ IN FACTORY DEFAULTS &SL -

SELECT LOCAL PARAMETERS

 

L

-

LIST PARAMETERS

&SR -

SELECT DOWNLINE LOAD PARAMETERS

 

ML

-

LINK USED PER CHANNEL

WL

-

WORD LENGTH SELECTION

 

THE FOLLOWING EXAMPLE WILL SELECT CHANNEL 1 AND SET ITS BAUD RATE

TO 2400 AND

THE WORD LENGTH TO 8 BITS:

ATC1B2400WL8 <ENTER>

FOR HELP ON A SPECIFIC COMMAND, ENTER “ATH” FOLLOWED BY A COMMAND LETTER

The H2 menu is as follows:

MULTIMUX EIGHT POSITION DIP-SWITCH DEFINITIONS AND CONFIGURATIONS

 

SWITCH 1 SWITCH 2 SWITCH 3 SWITCH 4 SWITCH 5 SWITCH 6 SWITCH 7 SWITCH 8

 

INITIATE

DSU

DSU

8/16

24/32

REMOTE

 

 

 

DWN

TYPE

TYPE

CHANNEL CHANNEL ACCESS

 

 

 

LINE

LINK A

LINK B

 

 

 

 

 

 

LOAD

 

 

 

 

 

 

 

UP =

ON

INTERNAL

INTERNAL

16/32

24/32CHAN

ENABLED

 

 

DN =

OFF

EXTERNAL

EXTERNAL

8/24

8/16CHAN

DISABLED

 

 

CURRENT SETTINGS:

 

 

 

 

 

 

 

DN

DN

DN

DN

DN

DN

DN

DN

The H3 menu is as follows:

COMPOSITE LINK CLOCKING AND SPEED COMMANDS

INTERNAL DSU

Page 45
Image 45
Multi-Tech Systems MMV1600 owner manual Store New, Parameters, H1-H7, H command menu is as follows General Help