interface connector type.

 

 

 

 

 

 

3. Voice/fax ribbon cable

1. Reconnect the voice/fax ribbon cable

not connected.

 

between the voicefax and aggregate

 

board. Refer to the

installation

 

 

 

procedures in Chapter 4.

 

 

 

2.

Call Tech Support for assistance,

 

refer to Chapter 8.

 

 

 

 

 

 

4. MV2 Board failure

1.

Perform the voice/fax loopback test

 

(test 12), refer to voice/fax channel

 

 

testing procedures in this chapter.

 

 

2.

Call Tech Support for assistance,

 

refer to Chapter 8.

 

 

 

 

 

A voice/fax channel

1. Voice/fax channel

1.

Verify that the voice/fax channel is

 

cannot communicate

configuration problem.

 

configured for the correct node and

 

with the remote site

 

 

channel destinaton and composite

 

link. Use the VL command to view

 

 

the voice/fax channel parameters,

 

refer to Chapter 5.

 

 

 

 

 

Table 7-2. Voice/Fax Troubleshooting Guide (Continued)

Condition

Possible Cause

 

 

Corrective Action

 

A voice/fax channel

2. Wrong type of telephone

1.

Ensure that the telephone cord

cannot communicate

cord.

connected to the voice/fax channel is

with the remote site

an RJ11 for

the FXO and/or FXS

(Continued)

 

 

connector(s) or E&M cable for the

 

E&M 1-5 connection.

 

 

 

 

No voice/fax

1. Frame ground not

1.

Attach PBX ground to MultiMux frame

 

communication

connected to PBX

 

ground screw.

 

E&M to E&M

2. Voice/fax configuration

1.

Verify that voice/fax channel is

problem.

 

configured properly, (E&M, wink or

 

 

dial tone, 2 or 4 wire, E&M type).

 

3. Incorrect E&M cabling.

1.

Verify connection of E&M cable to

 

PBX. See Appendix D as well as

 

 

PBX documentation.

 

 

2.

Verify that XSG LED lights when PBX

 

asserts the M lead and that RSG

 

 

LED lights when MultiMux asserts

 

 

 

the E lead.

 

Voice sounds broken

1. Excessive errors on

1. Examine composite statistics for up or grabled at times

composite link.

errors.

 

 

 

 

 

 

2.

Perform local and remote loop back

 

tests to determine failing unit or bad

 

 

communication line.

 

 

3.

Call phone company and

 

communication line.

 

 

 

 

 

 

 

4.

Call Tech Support for assistance,

 

refer to Chapter 8.

 

 

 

 

 

Page 69
Image 69
Multi-Tech Systems MMV1600 owner manual Cannot communicate