Composite Link Cabling

RS232C/V.24 *Configured Composite Link

To

External

Synchronous

Modem/DSU

Connector

PIN NO.

PIN NO.

1

1

2

2

3

3

4

4

5

5

7

7

8

8

15

15

17

17

20

20

25

25

CHASSIS GROUND (AA)

 

TRANSMIT DATA (BA)

 

RECEIVE DATA (BB)

To

REQUEST TO SEND (CA)

MultiMux

CLEAR TO SEND (CB)

External

SIGNAL GROUND (AB)

Modem/DSU

Connector

CARRIER DETECT (CF)

 

TRANSMIT CLOCK (DB)

 

RECEIVE CLOCK (DD)

 

DATA TERMINAL READY (CD)

 

V.35 Adapter Cable Configured on a RS232C/V.35

**Composite Link

 

V.35 34-PIN

 

25-PIN

 

CONNECTOR (MALE)

CONNECTOR (FEMALE)

 

 

 

 

 

 

 

A

 

 

1

PROTECTIVE GROUND

 

 

 

 

B

 

 

7

SIGNAL GROUND

 

 

 

 

C

 

 

4

REQUEST TO SEND

 

 

 

 

D

 

 

5

CLEAR TO SEND

 

 

 

 

E

 

 

6

DATA SET READY

 

 

 

 

F

 

 

8

DATA CARRIER DETECT

 

 

 

 

H

 

 

20

DATA TERMINAL READY

 

 

 

 

P

 

 

2

TRANSMIT DATA A

 

 

 

 

R

 

 

3

RECEIVE DATA A

 

 

 

 

S

 

 

12

TRANSMIT DATA B

 

 

 

 

T

 

 

22

RECEIVE DATA B

 

 

 

 

U

 

 

23

EXTERNAL TX CLOCK A

 

 

 

 

V

 

 

17

RECEIVE CLOCK A

 

 

 

 

W

 

 

25

EXTERNAL TX CLOCK B

 

 

 

 

X

 

 

18

RECEIVE CLOCK B

 

 

 

 

Y

 

 

15

TRANSMIT CLOCK A

 

 

 

 

a

 

 

21

TRANSMIT CLOCK B

 

 

 

 

 

 

 

 

 

*The MultiMux RS232C interface circuits have been designed to meet the electrical specificaitons given in EIA (Electronic Industries Association RS232C and CCITT (Consultative Committee International Telegraph and Telephone) V.24 Stanards.

**When configured for V.35 interface operation on composite link A or B, the V.35 adapter cable should be used. This cable uses a 25-pin female connector at one end and a 34-pin winchester male connector at the other end.

Page 81
Image 81