Multi-Tech Systems MMV1600 owner manual RD LED on

Models: MMV1600

1 111
Download 111 pages 32 Kb
Page 66
Image 66

not communicating

 

not installed on Supervisory

 

supervisory console, refer to comm

with mux command

Console.

 

software user’s manual forinstallation.

 

 

 

port

2.

Bad cable or cable

1.

Check RS232 cable connections

 

 

 

 

 

connection

between supervisory

 

 

console and COMMAND PORT on

 

 

 

MultiMux for loose connection or

 

bent pins, refer to Supervisory

 

 

 

 

Console Installation procedures in

 

 

Chapter 4

 

 

 

 

 

 

 

 

 

 

2.

Check RS232 cable connections

 

 

between supervisory console and

 

 

COMMAND PORT on MultiMux for

 

 

 

correct cable wiring, refer to Cable

 

Diagrams in Appendix

C.

 

 

 

 

 

 

 

Supervisory Console

1. Incorrect command

1.

Verify command modem baud rate is

not communicating

modem baud rate

 

set to 2400 bps, refer to Comm

with command mode

 

Software

User’s Manual.

 

 

 

 

 

 

 

 

 

 

2.

Call Tech Support for assistance,

 

 

refer to Chapter 8

 

 

 

 

 

 

 

Garbage on

1. Incorrect session

1.

Verify session parameters (data bits

Supervisory

parameters

 

of 8, parity none, 1 stop bit), refer to

Console Screen

 

comm

software user’s manual for

 

 

 

parameter settings.

 

 

 

 

 

2.

Call Tech Support for assistance,

 

 

refer to Chapter 8

 

 

 

 

 

 

 

Composite Link down

1. Composite Link cabling

1.

If internal DSU is installed, check

 

 

with CTS, XMT, and

connection.

 

Composite Link cabling for loose

RD LEDs ON

 

 

 

 

 

 

 

 

 

 

2.

If external DSU or modem is

 

 

installed, check RS232C/V.35 cable

 

 

between devices for loose

 

 

 

connection or bent pin.

 

 

 

 

 

 

2. Not receiving data from

1.

Verify that both muxes are powered

 

remote mux

 

ON.

 

 

 

 

 

 

 

 

2.

Verify that both muxes are

 

 

connected to communications line.

 

 

 

 

 

 

 

Table 7-1. Data Troubleshooting Guide(Continued)

 

Condition

 

Possible Cause

 

 

Corrective Action

 

 

Composite link down

2. Not receiving data from

3.

If external modem are used, verify

with CTS, XMT and

remote mux (Continued)

that they are powered ON and

 

 

 

 

RD LEDs ON

 

 

 

connected to the communication

 

 

(Continued)

 

 

 

line and Mux composite link.

 

 

 

 

 

4.

Call Tech Support for assistance,

 

 

 

 

 

 

refer to Chapter 8.

 

 

communication line.

3. Faulty communication line

1. Call phone company and verify

 

 

 

 

 

 

 

 

 

 

 

 

2.

Call Tech Support for assistance,

 

 

refer to Chapter 8.

 

 

 

 

 

 

 

Composite Link down

1. Both Muxes set up for

1.

Remove front cover of both muxes

 

 

with CD, CTS, XMT and

 

down line loading

 

and verify if DIP-Switch 1 is in the

 

 

RCV LEDs ON and

 

 

 

UP (ON) position.

 

 

RD LED ON

 

 

2.

Place DIP-Switch 1 on one of the

 

 

 

 

 

 

 

muxes in the DOWN (OFF) position.

 

 

 

 

 

 

 

 

3.

Call Tech Support for assistance,

 

 

refer to Chapter 8.

 

 

 

 

 

 

 

 

2. Internal DSU speeds

1.

Verify internal DSU speeds with $L

on local and remote

 

command, refer to Chapter 5.

 

 

 

 

 

 

 

muxes do not match.

 

 

 

 

 

Composite link down

1. External modem settings

1.

Verify that external modem is set for

 

 

with CD, CTS and

 

remote mux

 

sync, full duplex and internal clocking.

 

 

Page 66
Image 66
Multi-Tech Systems MMV1600 owner manual RD LED on