2.3 Configuration 2

Configuration 2 is two MultiMux MMV1616C sixteen channel multiplexers with two external Multi-Tech 56K bps Digital Service Units (DSUs) linking the two sites over a Digital Data Service (DDS) network. The RS232C interface on The DSUs is connected to COMPOSITE LINK A EXTERNAL MODEM/DSU connector on the back panel of the MMV1616C. The MMV1616Cs are set up for an external link device with a maximum link speed of 56,000 bps. Composite link A needs to be set up for external clocking. Both external DSUs must be set for DDS clocking. Configuration 2 is shown in Figure 2-2.

Composite Link

PDN

Asynchronous

 

Asynchronous

Channel

 

Dial-Up Line

Channel

 

 

MT56DSU2

MT56DSU2

MultiMux 16

 

 

 

 

MultiMux 16

MultiMux MMV1616

 

MultiMux MMV1616

Unix Host

Local Site

(Node 1)

Printer

Terminal Terminal

Printer

TerminalPrinter

Remote Site

(Node 2)

Figure 2-2. Configuration 2

The channels are set up with the same considerations as in Configuration 1. The composite link configuration may be changed using the List Composite Link Configuration ($L) command which is shown in the following example.

DSU

 

 

LOOP

TYPE

SPEED

CLOCKING

BACK

EXTERNAL

56000

EXTERNAL

OFF

Configuration 2 Composite Link Configuration

Page 22
Image 22