2.7 Configuration 6

Configuration 6 is the data/voice/fax configuration with two MultiMux MMV1608C/56/V multiplexers with single composite link connecting a minicomputer and a telephone and/or fax machine at the local site to a group of remote terminals and printer on the data part of the network and a second set of telephone and/or fax machine on the voice/fax channels. The FXS to FXS configuration is shown in Figure 2-6. In this configuration the data communications is set up per configuration 1.

This configuration has the MV2 Voice/Fax board installed in the MMV1608/56/V multiplexers for the voice over data communications. Both sites have the MV2 Voice/Fax boards connecting VOICE/FAX CHANNEL 1and/or 2 FXS connector(s) on the back panel of the multiplexer to either a telephone and/or a fax machine or both.

Terminal

Terminal

Printer

Asynchronous

 

 

Asynchronous

Channel

 

 

 

 

 

 

 

 

PDN

 

Channel

 

Modem

 

 

 

 

 

 

 

Composite Link

MultiMux 16

 

 

 

MultiMux 16

 

 

Terminal

 

 

 

Multiplexer

 

 

 

Multiplexer

 

Minicomputer

 

PC

 

Voice/Fax

 

 

 

Voice/Fax

Voice/Fax Channel 2 FXS

Channel 1

Voice/Fax

FXS

Channel 1

 

 

Channel 2 FXS

 

 

 

FXS

 

 

 

 

 

 

 

 

 

Telephone

 

 

Telephone

Fax

 

Local Site

 

 

Remote Site

 

Fax

 

 

 

 

 

(Node 1)

 

(Node 2)

Figure 2-6. Configuration 6 (FXS to FXS)

Both sites are configured for an FXS configuration on voice/fax channel 1and/or 2 using the V1LIFXS command and/or V2LIFXS command and setting the Remote Interface type for the same thing using the V1RIFXS and/or V2RIFXS. The parameters for local voice/fax channels can be displayed using the VL (List the voice/fax channel parameters) command. The voice/fax channel parameters are shown in Configuration 6 Voice/Fax Channel Parameters. The voice/fax channel parameters are described in Chapter 5 Commands of this manual.

LOCAL VOICE/FAX PARAMETERS CHANNEL1

LOCAL VOICE/FAX PARAMTERS CHANNEL 2

PARAMETER

STATUS

PARAMETER

STATUS

DESTINATION CHANNEL:

01

DESTINATION CHANNEL:

02

DESTINATION NODE:

02

DESTINATION NODE:

02

LINK A/B/D:

A

LINK A/B/D:

A

DIGITIZING RATE:

16000

DIGITIZING RATE:

16000

OUTPUT LEVEL ATTEN.:

12

OUTPUT LEVEL ATTEN.:

12

INPUT LEVEL GAIN:

03

INPUT LEVEL GAIN:

03

SILENCE SUPPRESSION:

00

SILENCE SUPPRESSION:

00

LOCAL INTERFACE TYPE:

FXS

LOCAL INTERFACE TYPE:

FXS

GROUND/LOOP START (FXS):

LOOP

GROUND/LOOP START (FXS):

LOOP

2 OR 4 WIRE (E&M):

2 WIRE

2 OR 4 WIRE (E&M):

2 WIRE

DIALTONE/WINK (E&M):

N/A

DIALTONE/WINK (E&M):

N/A

WINK TIMER (E&M)

N/A

WINK TIMER (E&M)

N/A

REMOTE INTERFACE TYPE:

FXS

REMOTE INTERFACE TYPE:

FXS

GROUND/LOOP START (FXS):

LOOP

GROUND/LOOP START (FXS):

LOOP

2 OR 4 WIRE (E&M):

2 WIRE

2 OR 4 WIRE (E&M):

2 WIRE

DIALTONE/WINK (E&M):

N/A

DIALTONE/WINK (E&M):

N/A

Page 29
Image 29