As you change parameters, they will not actually be incorporated into your running system until you execute a Store New Parameters (&W) command.

Table 4-3. Configuration Procedure

Step

 

 

 

 

 

Procedure

 

 

 

 

 

Async Channels

 

 

 

 

 

 

 

 

 

 

 

 

14 Execute the parameter display command to display the current channel

parameter status for your local

 

 

 

MultiMux by entering the following:

 

 

 

 

 

 

 

 

 

 

 

ATL (hit Return)

 

 

 

 

 

 

 

 

The following will be displayed on your supervisory console for a MultiMux MMV1616:

 

 

 

 

 

 

 

Local Channel Parameters/ Node # 00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STP

 

FLOW

ENQ/

 

 

PASS

PASS DEST DEST

LINK

 

CHN SPD WD BIT PAR

CTRL

ACK

ECHO

PACE

EIA

XON

CHN NODE

A/B

 

01

19200

8

1

NONE

CTS

OFF

OFF

OFF

OFF

OFF

01

01

A

 

02

19200

8

1

NONE

CTS

OFF

OFF

OFF

OFF

OFF

02

01

A

 

03

19200

8

1

NONE

CTS

OFF

OFF

OFF

OFF

OFF

03

01

A

 

04

19200

8

1

NONE

CTS

OFF

OFF

OFF

OFF

OFF

04

01

A

 

05

19200

8

1

NONE

CTS

OFF

OFF

OFF

OFF

OFF

05

01

A

 

06

19200

8

1

NONE

CTS

OFF

OFF

OFF

OFF

OFF

06

01

A

 

07

19200

8

1

NONE

CTS

OFF

OFF

OFF

OFF

OFF

07

01

A

 

08

19200

8

1

NONE

CTS

OFF

OFF

OFF

OFF

OFF

08

01

A

 

09

19200

8

1

NONE

CTS

OFF

OFF

OFF

OFF

OFF

09

01

A

 

10

19200

8

1

NONE

CTS

OFF

OFF

OFF

OFF

OFF

10

01

A

 

11

19200

8

1

NONE

CTS

OFF

OFF

OFF

OFF

OFF

11

01

A

 

12

19200

8

1

NONE

CTS

OFF

OFF

OFF

OFF

OFF

12

01

A

 

13

19200

8

1

NONE

CTS

OFF

OFF

OFF

OFF

OFF

13

01

A

 

14

19200

8

1

NONE

CTS

OFF

OFF

OFF

OFF

OFF

14

01

A

 

15

19200

8

1

NONE

CTS

OFF

OFF

OFF

OFF

OFF

15

01

A

 

16

19200

8

1

NONE

CTS

OFF

OFF

OFF

OFF

OFF

16

01

A

 

15Based on the listed conditions for each channel, reconfigure the parameters to match your actual channel requirements by entering commands as described in Chapter 5.

As you change operational parameters, they will not actually be incorporated into your running system until you execute a Store New Parameters (&W) command.

Table 4-3. Configuration Procedure

Step

Procedure

Voice/Fax Channels

16To display the current Voice/Fax channel parameters, enter the following: ATVL (hit Return)

The following will be displayed on your supervisory console for the Voice/Fax channels:

LOCAL VOICE/FAX PARAMETERS CHANNEL 1 LOCAL VOICE/FAX PARAMETERS CHANNEL 2

PARAMETER

STATUS

PARAMETER

STATUS

DESTINATION CHANNEL:

01

DESTINATION CHANNEL:

02

DESTINATION NODE:

02

DESTINATION NODE:

02

LINK A/B/D:

A

LINK A/B/D:

A

DIGITIZING RATE:

16000

DIGITIZING RATE:

16000

OUTPUT LEVEL ATTEN.:

12

OUTPUT LEVEL ATTEN.:

12

INPUT LEVEL GAIN:

03

INPUT LEVEL GAIN:

03

SILENCE SUPPRESSION:

00

SILENCE SUPPRESSION:

00

LOCAL INTERFACE TYPE:

FXS

LOCAL INTERFACE TYPE:

FXS

GROUND/LOOP START (FXS):

LOOP

GROUND/LOOP START (FXS):

LOOP

2 OR 4 WIRE (E&M):

2 WIRE

2 OR 4 WIRE (E&M):

2 WIRE

DIALTONE/WINK (E&M):

N/A

DIALTONE/WINK (E&M):

N/A

WINK TIMER (E&M):

N/A

WINK TIMER (E&M):

N/A

REMOTE INTERFACE TYPE:

FXS

REMOTE INTERFACE TYPE:

FXS

GROUND/LOOP START (FXS):

LOOP

GROUND/LOOP START (FXS):

LOOP

2 OR 4 WIRE (E&M):

2 WIRE

2 OR 4 WIRE (E&M):

2 WIRE

DIALTONE/WINK (E&M):

N/A

DIALTONE/WINK (E&M):

N/A

Page 40