2.8 Configuration 7

Configuration 7 is the data/voice/fax configuration with two MultiMux MMV1608C/56/V multiplexers with single composite link connecting a minicomputer and a PBX E&M trunk at the local site to a group of remote terminals and printer on the data part of the network and a telephone and/or fax machine on the remote voice/fax channels. The E&M to FXS configuration is shown in Figure 2-7. In this configuration the data communications is set up per configuration 1.

This configuration has the MV2 Voice/Fax board installed in the MMV1608/56/V multiplexers for the voice over data communications. The local site has the MV2 Voice/Fax board connecting VOICE/FAX CHANNEL 1and/or 2 E&M connector(s) on the back panel of the local multiplexer to a PBX E&M trunk. At the remote site the MV2 Voice/Fax board is connecting VOICE/FAX CHANNEL 1 and/or 2 FXS connector(s) on the back panel of the remote multiplexer to a telephone and/or a fax machine on the second channel.

Terminal

Terminal

Printer

Asynchronous

 

 

Asynchronous

Channel

 

 

 

 

 

 

 

 

PDN

 

Channel

 

Modem

 

 

MultiTech

 

 

 

 

 

MultiMux 16

 

 

 

MultiTech

Composite Link

 

 

 

 

MultiMux 16

 

 

Terminal

 

 

 

Multiplexer

 

 

 

Multiplexer

 

Minicomputer

 

PC

 

Voice/Fax

 

 

 

Voice/Fax

Voice/Fax Channel 2 FXS

Channel 1 E&M

Voice/Fax

Channel 1

 

 

 

Channel 2 E&M

FXS

 

 

 

 

 

PSTN

Telephone Fax

Remote Site

(Node 2)

Trunk

Trunk

Trunk

Station

Station

PBX

Telephone

Local Site

(Node 1)

Figure 2-7. Configuration 7 (E&M I-V to FXS)

The local site is configured for an E&M configuration on both voice/fax channels using the V1LIE&M2D4 command for channel 1 and V2LIE&M2D4) command for channel 2 and setting the Remote Interface type for an FXS configuration using the V1RIFXS and or V2RIFXS commands depending on whether one or both of the remote voice/fax channels are used. The parameters for the local and remote voice/fax channels can be displayed using the VL (List the voice/ fax channel parameters) command. The voice/fax channel parameters are shown in Configuration 7 Voice/Fax Channel Parameters. The voice/fax channel parameters are described in Chapter 5 Commands of this manual.

LOCAL VOICE/FAX PARAMETERS CHANNEL1

LOCAL VOICE/FAX PARAMTERS CHANNEL 2

PARAMETER

STATUS

PARAMETER

STATUS

DESTINATION CHANNEL:

01

DESTINATION CHANNEL:

02

DESTINATION NODE:

02

DESTINATION NODE:

02

LINK A/B/D:

A

LINK A/B/D:

A

DIGITIZING RATE:

16000

DIGITIZING RATE:

16000

OUTPUT LEVEL ATTEN.:

14

OUTPUT LEVEL ATTEN.:

14

INPUT LEVEL GAIN:

05

INPUT LEVEL GAIN:

05

SILENCE SUPPRESSION:

00

SILENCE SUPPRESSION:

00

LOCAL INTERFACE TYPE:

E&M 2

LOCAL INTERFACE TYPE:

E&M 2

GROUND/LOOP START (FXS):

N/A

GROUND/LOOP START (FXS):

N/A

2 OR 4 WIRE (E&M):

4 WIRE

2 OR 4 WIRE (E&M):

4 WIRE

DIALTONE/WINK (E&M):

DIAL

DIALTONE/WINK (E&M):

DIAL

WINK TIMER (E&M)

N/A

WINK TIMER (E&M)

N/A

REMOTE INTERFACE TYPE:

FXS

REMOTE INTERFACE TYPE:

FXS

GROUND/LOOP START (FXS):

LOOP

GROUND/LOOP START (FXS):

LOOP

2 OR 4 WIRE (E&M):

2 WIRE

2 OR 4 WIRE (E&M):

2 WIRE

DIALTONE/WINK (E&M):

N/A

DIALTONE/WINK (E&M):

N/A

Page 31
Image 31