CHN70200

Pre-Operation

 

 

Operational Modes

 

Depress WCE first...

Always know the operational mode of the nailer before using. Failure to

 

know the operational mode could result in death or serious injury.

 

This nailer may be operated in the “Sequential” mode (as supplied by the

 

manufacturer) or “Bump” mode. the tool may be converted from one mode to the other

 

by firmly pressing the conversion switch from one position to the other.

 

Press the conversion switch to the “

” side to activate Sequential Mode.

 

Press the conversion switch to the “

” side to activate Bump Mode.

Work Surface

Press either side to the middle position to activate the Safety Lockout Mode.

Then pull trigger.

 

Sequential Mode

 

 

This method is recommended when precise nail placement is required. Operation in

 

this mode requires trigger to be pulled each time a nail is driven. Nailer can be actuated

 

by depressing the Work Contact Element (WCE) against work surface followed by

 

pulling the trigger.

 

 

The trigger must be released after each fastener is driven to allow tool to reset.

 

Since the tool can only be actuated by first removing the finger from the trigger, this

 

is considered to be a more restrictive mode of operation, suitable for less experienced

Work Surface

users.

 

 

Figure 14 - Sequential Mode

Bump Mode

 

 

 

This method is recommended when less precise nail placement is required. Operation

 

in this mode requires trigger to be depressed with nailer off of the work surface. Then,

Pull trigger first...

the nose of the nailer is tapped against the work surface causing a nail to be driven.

 

Each time the Work Contact Element is depressed, a nail is driven into the work

 

surface. Extreme care should be taken because a nail will be driven when the WCE is

 

pressed against any surface.

 

 

Since the tool can be actuated without removing the finger from the trigger, this is

 

considered to be a less restrictive mode, suitable for more experienced users.

 

Safety Lockout Mode

 

 

When the conversion switch is pressed into the middle position, the trigger is in Safety

 

Lockout Mode. In this mode, no combination of WCE and trigger activations will allow

 

the tool to cycle or fire. If tool does operate while in Safety Lockout Mode, contact

 

Campbell Hausfeld for technical support, and do not use the nailer until repaired.

 

Work Contact Element (WCE)

Work Surface

Then depress WCE.

Check the operation of the Work Contact Element (WCE) trip mechanism

 

before each use. The WCE must move freely without binding through its

 

entire travel distance. The WCE spring must return the WCE to its fully extended position after

 

being depressed. Do not operate the nailer if the WCE trip mechanism is not operating properly.

 

Personal injury may occur.

 

 

1. Disconnect the air supply from the nailer.

 

2. Make sure the trigger and Work Contact Element (WCE) move freely up and down

 

without sticking or binding.

 

 

NOTE: If the tool is not loaded with nails, the anti-dry fire feature will not allow the

 

WCE to be depressed.

 

Work Surface

3. Reconnect air supply to the nailer.

 

Figure 15 - Bump Mode

4. Use a scrap piece of wood as a work surface.

 

12www.chpower.com

Image 12
Contents Brad Nailer Table of Contents Specifications DescriptionModel CHN70200 Safety Guidelines Safety SymbolsImportant Safety Information Personal Safety Electrical SafetyTool Use and Care Do not expose tool to extreme heat Assembly UnpackingGlossary Quick CouplerFeatures Getting To Know Your Brad Nailer Like a ProSet-Up LubricationMinimum Components Required For Hook-up Hook-up Instructions For Nailer to Air SupplyAdjusting The Nail Penetration Installing No-Mar TipLoading / Unloading The Nailer Loading the NailerPre-Operation Electronics on / OFF Switch Electronic ON/OFF SwitchOperation Firing the NailerMaintenance StorageTechnical Service Fastener Interchange InformationFasteners Troubleshooting Guide Symptom Cause SolutionFor Replacement Parts or Technical Assistance, Call Replacement Parts List for Brad Nailer Part Description QtyWarranty What is not Covered Under this WarrantyCloueuse à Clous sans Tête Pour l’information sur les pièces, produits et services Table des MatièresSpécifications Modèle CHN70200Symboles de sécurité Directives de SécuritéImportantes Instructions De Sécurité Importantes Instructions De Sécurité Suite Sécurité personnelleSécurité Électrique Utilisation et entretien de l’outilNe pas exposer l’outil à une chaleur extrême Déballage AssemblageContenu Autres Articles NON InclusGlossaire Raccord RapideCaractéristiques Installation LubrificationComposants Minimaux Requis Pour LE Raccord Diamètre Longueur ’acheminementInstallation suite Installer L’EMBOUT ANTI-MARQUESCHARGER/DÉCHARGER LA Cloueuse Ajuster LA Pénétration DU ClouPré-opération Modes D’OPÉRATIONPointe DE Contact PC Pré-opération Suite Interrupteur MARCHE/ARRÊT ÉlectroniqueFonctionnement Utiliser LA CloueuseRangement EntretienService Technique Entretien SuiteInformation SUR LES Attaches Interchangeables AttachesGuide de dépannage Symptôme Causes possibles Action correctivePour pièces de rechange ou assistance technique, appeler Trousses DE Pièces DE Rechange Garantie Limitée LA Présente Garantie NE Couvre PASClavadora para Acabado Índice Por información sobre piezas, productos y serviciosDescripción EspecificacionesMedidas de Seguridad Símbolos de seguridadImportantes Instrucciones De Seguridad Proposición 65 de CaliforniaImportantes Instrucciones De Seguridad Continuación Seguridad PersonalSeguridad Eléctrica Uso y Cuidado de la HerramientaNo exponga la herramienta a calor extremo Desempaque EnsamblajeGuarde Estas Instrucciones No LAS Deseche ContenidosGlosario Figura Acoplador rápidoConozca su clavadora de puntillas como un profesional CaracterísticasConfiguración LubricaciónComponentes Mínimos Necesarios Para LA Conexión Diámetro Largo del RecorridoConfiguración Continuación Para Cargar Y Descargar LA ClavadoraAjuste DE LA Penetración DEL Clavo Instalación DE LA Punta AntirrayonesPre-Funcionamiento Modos DE FuncionamientoElemento DE Contacto DE Trabajo WCE Pre-Funcionamiento continuación FiguraFuncionamiento Disparo DE LA ClavadoraFuncionamiento continuación AlmacenamientoMantenimiento Mantenimiento continuación Procedimiento DE Ensamblaje Para LOS SellosServicio Técnico Información DE Intercambio DE SujetadoresGuía de resolución de problemas Problema Causa SoluciónSírvase proporcionar la siguiente información Lista de piezas de repuesto para la clavadora para acabado No. de Número de Descripción Repuesto CtdGarantía Limitada LO QUE no Esta Cubierto POR Esta Garantia

CHN70200 specifications

The Campbell Hausfeld CHN70200 is a versatile and reliable air compressor designed to meet the needs of both DIY enthusiasts and professionals. This unit offers a blend of performance and efficiency, making it an excellent choice for a variety of applications, such as inflating tires, powering pneumatic tools, and other tasks requiring a dependable source of compressed air.

One of the standout features of the CHN70200 is its powerful 1.0 horsepower motor, which operates on a 120V outlet, making it suitable for home and garage use. With a maximum pressure of 125 PSI, this air compressor delivers a consistent and reliable airflow, ensuring that it can handle a range of demanding tasks with ease. The 2-gallon vertical tank design not only provides ample air storage but also saves valuable floor space, making it a practical choice for tight work environments.

The CHN70200 is equipped with a quick-connect coupler, allowing users to easily attach and detach air hoses and tools. This convenience reduces downtime during tasks, enabling users to stay productive. Additionally, its noise level is relatively low, thanks to its oil-free pump design, which operates quietly and efficiently. This feature is particularly valuable in residential areas where noise restrictions may be a concern.

Moreover, the oil-free pump technology means that maintenance is minimal. Users do not have to worry about oil changes, which translates to lower operating costs and increased longevity for the compressor. This feature, combined with the lightweight and portable design, makes the Campbell Hausfeld CHN70200 a user-friendly option for those on the go.

Safety is also a priority with the CHN70200 as it comes equipped with built-in safety features, including an automatic thermal overload protection switch. This ensures that the compressor will shut off if it overheats, safeguarding the unit and prolonging its lifespan.

In summary, the Campbell Hausfeld CHN70200 air compressor excels in providing portability, efficiency, and ease of use. Its robust construction and user-friendly features make it a reliable choice for a host of applications, ensuring that whether for casual tasks or more intensive projects, users have access to the power they need. With its combination of features, the CHN70200 stands out as a valuable tool for any toolkit.