Campbell Hausfeld CHN70200 operating instructions Operation, Firing the Nailer

Page 14

Operating Instructions and Parts Manual

CHN70200

 

 

Operation

Nail Placement Laser Pointer

The tool is equipped with a laser mounted near the nose. Turn the electronics switch to the on position. When the Work Contact Element (WCE) touches the workpiece and slightly moves, the laser will shine on the spot where the nail will be driven. This can be seen through the wide slots in the WCE and / or no-mar tip. When the laser is in the desired location, simply fully press in the WCE and fire the tool.

This is a Class IIIA Laser Product that emits laser radiation.

Do not stare into beam or view directly with optical instruments.

NOTE: The laser will only show accurate placement when the depth control is set to maximum depth.

Firing the Nailer

1.Load fasteners (see Loading / Unloading the Nailer section).

2.Connect the air supply to the nailer.

An improperly functioning tool must not be used. Do not actuate the tool unless the tool is placed firmly against the work piece.

In Sequential Mode

Press the conversion switch to the “ ” side to activate Sequential Mode.

1.Slightly depress Work Contact element (WCE) against work surface.

2.Laser pointer will shine on spot where nail will be driven when the WCE slightly touches the work surface.

3.Fully depress WCE.

4.Pull trigger. Fastener will be driven into workpiece.

In Bump Mode (Laser should not be used in Bump Mode)

Press the conversion switch to the “ ” side to activate Bump Mode.

1.Remove tool from work surface. DO NOT point tool at yourself or others.

2.Pull trigger.

3.Firmly depress Work Contact element (WCE) against work surface. Tool will cycle.

4.Remove tool from work surface. Move tool to the next area where fastener is to be driven and repeat.

Low Nail Indicator Lights

The tool is equipped with lights on either side of the tool near the nose. Turn the electronics switch to the on position. When the nail count becomes 10 or so nails remaining in the magazine, the lights will come on yellow. You may reload at that time (See Loading the Nailer section). When the nail count becomes 5 or so remaining nails, the Anti-Dry Fire will engage and the lights will turn red. You must reload at that time.

Bubble Level

The tool is equipped with a bubble level located on the head cap. When the gun is in a horizontal driving orientation, a level condition can easily be observed and controlled by simply aligning the tool in such a manner whereas the bubble is between the center markings on the length of the level. The same is true when in a vertically downward driving orientation by aligning the tool such that the bubble is centered in the circular marking at the top of the level.

Figure 19 - Nail Placement Laser Pointer

Figure 20 - Low Nail Indicator Lights

Figure 21 - Bubble Level

14www.chpower.com

Image 14
Contents Brad Nailer Table of Contents Model CHN70200 SpecificationsDescription Important Safety Information Safety GuidelinesSafety Symbols Tool Use and Care Personal SafetyElectrical Safety Do not expose tool to extreme heat Assembly UnpackingGlossary Quick CouplerFeatures Getting To Know Your Brad Nailer Like a ProMinimum Components Required For Hook-up Set-UpLubrication Hook-up Instructions For Nailer to Air SupplyLoading / Unloading The Nailer Adjusting The Nail PenetrationInstalling No-Mar Tip Loading the NailerPre-Operation Electronics on / OFF Switch Electronic ON/OFF SwitchOperation Firing the NailerMaintenance StorageFasteners Technical ServiceFastener Interchange Information Troubleshooting Guide Symptom Cause SolutionFor Replacement Parts or Technical Assistance, Call Replacement Parts List for Brad Nailer Part Description QtyWarranty What is not Covered Under this WarrantyCloueuse à Clous sans Tête Pour l’information sur les pièces, produits et services Table des MatièresSpécifications Modèle CHN70200Importantes Instructions De Sécurité Symboles de sécuritéDirectives de Sécurité Sécurité Électrique Importantes Instructions De Sécurité SuiteSécurité personnelle Utilisation et entretien de l’outilNe pas exposer l’outil à une chaleur extrême Contenu DéballageAssemblage Autres Articles NON InclusGlossaire Raccord RapideCaractéristiques Composants Minimaux Requis Pour LE Raccord InstallationLubrification Diamètre Longueur ’acheminementCHARGER/DÉCHARGER LA Cloueuse Installation suiteInstaller L’EMBOUT ANTI-MARQUES Ajuster LA Pénétration DU ClouPointe DE Contact PC Pré-opérationModes D’OPÉRATION Pré-opération Suite Interrupteur MARCHE/ARRÊT ÉlectroniqueFonctionnement Utiliser LA CloueuseRangement EntretienInformation SUR LES Attaches Interchangeables Service TechniqueEntretien Suite AttachesGuide de dépannage Symptôme Causes possibles Action correctivePour pièces de rechange ou assistance technique, appeler Trousses DE Pièces DE Rechange Garantie Limitée LA Présente Garantie NE Couvre PASClavadora para Acabado Índice Por información sobre piezas, productos y serviciosDescripción EspecificacionesImportantes Instrucciones De Seguridad Medidas de SeguridadSímbolos de seguridad Proposición 65 de CaliforniaSeguridad Eléctrica Importantes Instrucciones De Seguridad ContinuaciónSeguridad Personal Uso y Cuidado de la HerramientaNo exponga la herramienta a calor extremo Guarde Estas Instrucciones No LAS Deseche DesempaqueEnsamblaje ContenidosGlosario Figura Acoplador rápidoConozca su clavadora de puntillas como un profesional CaracterísticasComponentes Mínimos Necesarios Para LA Conexión ConfiguraciónLubricación Diámetro Largo del RecorridoAjuste DE LA Penetración DEL Clavo Configuración ContinuaciónPara Cargar Y Descargar LA Clavadora Instalación DE LA Punta AntirrayonesElemento DE Contacto DE Trabajo WCE Pre-FuncionamientoModos DE Funcionamiento Pre-Funcionamiento continuación FiguraFuncionamiento Disparo DE LA ClavadoraMantenimiento Funcionamiento continuaciónAlmacenamiento Servicio Técnico Mantenimiento continuaciónProcedimiento DE Ensamblaje Para LOS Sellos Información DE Intercambio DE SujetadoresGuía de resolución de problemas Problema Causa SoluciónSírvase proporcionar la siguiente información Lista de piezas de repuesto para la clavadora para acabado No. de Número de Descripción Repuesto CtdGarantía Limitada LO QUE no Esta Cubierto POR Esta Garantia

CHN70200 specifications

The Campbell Hausfeld CHN70200 is a versatile and reliable air compressor designed to meet the needs of both DIY enthusiasts and professionals. This unit offers a blend of performance and efficiency, making it an excellent choice for a variety of applications, such as inflating tires, powering pneumatic tools, and other tasks requiring a dependable source of compressed air.

One of the standout features of the CHN70200 is its powerful 1.0 horsepower motor, which operates on a 120V outlet, making it suitable for home and garage use. With a maximum pressure of 125 PSI, this air compressor delivers a consistent and reliable airflow, ensuring that it can handle a range of demanding tasks with ease. The 2-gallon vertical tank design not only provides ample air storage but also saves valuable floor space, making it a practical choice for tight work environments.

The CHN70200 is equipped with a quick-connect coupler, allowing users to easily attach and detach air hoses and tools. This convenience reduces downtime during tasks, enabling users to stay productive. Additionally, its noise level is relatively low, thanks to its oil-free pump design, which operates quietly and efficiently. This feature is particularly valuable in residential areas where noise restrictions may be a concern.

Moreover, the oil-free pump technology means that maintenance is minimal. Users do not have to worry about oil changes, which translates to lower operating costs and increased longevity for the compressor. This feature, combined with the lightweight and portable design, makes the Campbell Hausfeld CHN70200 a user-friendly option for those on the go.

Safety is also a priority with the CHN70200 as it comes equipped with built-in safety features, including an automatic thermal overload protection switch. This ensures that the compressor will shut off if it overheats, safeguarding the unit and prolonging its lifespan.

In summary, the Campbell Hausfeld CHN70200 air compressor excels in providing portability, efficiency, and ease of use. Its robust construction and user-friendly features make it a reliable choice for a host of applications, ensuring that whether for casual tasks or more intensive projects, users have access to the power they need. With its combination of features, the CHN70200 stands out as a valuable tool for any toolkit.