Campbell Hausfeld CHN70200 operating instructions Unpacking, Assembly

Page 7

Operating Instructions and Parts Manual

CHN70200

 

 

Important Safety Information (Continued)

Service

a.Tool service must be performed only by qualified repair personnel.

b.When servicing a tool, use only identical replacement parts. Use only authorized parts.

c.Use only the lubricants supplied with the tool or specified by the manufacturer.

Disconnect air supply and release tension from the pusher before attempting to clear jams because fasteners can be ejected from the front of the nailer.

Personal injury may occur.

Air Source

a.Never connect to an air source that is capable of exceeding 200 psi. Over pressurizing the tool is able to result in bursting, abnormal operation, breakage of the tool or serious injury to persons. Use only clean, dry, regulated compressed air at the rated pressure or within the rated pressure range as marked on the tool. Always verify prior to using the tool that the air source has been adjusted to the rated air pressure or within the rated air-pressure range.

b.Never use oxygen, carbon dioxide, combustible gases or any bottled gas as an air source for the tool. Such gases are capable of explosion and serious injury to persons.

Air compressors providing air to the nailer should follow the requirements established

by the American National Standards Institute Standard B19.3-1991; Safety Standard for Compressors for Process Industries. Contact your air compressor manufacturer for information.

Save These Instructions

Do Not Discard

The DANGER, WARNING, CAUTION, and NOTICE notifications and instructions in this manual cannot cover all possible conditions and situations that may occur. It must be understood by the operator that common sense and caution are factors which cannot be built into this product, but must be supplied by the operator.

Unpacking

After unpacking the unit, inspect carefully for any damage that may have occurred during transit. Check for loose, missing or damaged parts. Make sure to tighten fittings, bolts, etc., before putting unit into service. Check to be sure all supplied accessories are enclosed with the unit. In case of questions, damaged or missing parts, please call 1-800-543-6400 for customer assistance.

Contents

uBrad Nailer

u2 inch, 18 gauge fasteners

uOperating Instructions

uWarranty Card

uCarry Bag

Additional Items Not Included

uCompressor (must be able to maintain a minimum of 60 psi when the nailer is being used)

uAir hose

uSmall tool for clearing jams

uThreadlock glue

uANSI Z87 eye protection

uHearing protection and other personal protective equipment as required

Assembly

This tool comes fully assembled.

www.chpower.com

Image 7
Contents Brad Nailer Table of Contents Description SpecificationsModel CHN70200 Safety Symbols Safety GuidelinesImportant Safety Information Electrical Safety Personal SafetyTool Use and Care Do not expose tool to extreme heat Unpacking AssemblyQuick Coupler GlossaryGetting To Know Your Brad Nailer Like a Pro FeaturesHook-up Instructions For Nailer to Air Supply Set-UpLubrication Minimum Components Required For Hook-upLoading the Nailer Adjusting The Nail PenetrationInstalling No-Mar Tip Loading / Unloading The NailerPre-Operation Electronic ON/OFF Switch Electronics on / OFF SwitchFiring the Nailer OperationStorage MaintenanceFastener Interchange Information Technical ServiceFasteners Symptom Cause Solution Troubleshooting GuideFor Replacement Parts or Technical Assistance, Call Part Description Qty Replacement Parts List for Brad NailerWhat is not Covered Under this Warranty WarrantyCloueuse à Clous sans Tête Table des Matières Pour l’information sur les pièces, produits et servicesModèle CHN70200 SpécificationsDirectives de Sécurité Symboles de sécuritéImportantes Instructions De Sécurité Utilisation et entretien de l’outil Importantes Instructions De Sécurité SuiteSécurité personnelle Sécurité ÉlectriqueNe pas exposer l’outil à une chaleur extrême Autres Articles NON Inclus DéballageAssemblage ContenuRaccord Rapide GlossaireCaractéristiques Diamètre Longueur ’acheminement InstallationLubrification Composants Minimaux Requis Pour LE RaccordAjuster LA Pénétration DU Clou Installation suiteInstaller L’EMBOUT ANTI-MARQUES CHARGER/DÉCHARGER LA CloueuseModes D’OPÉRATION Pré-opérationPointe DE Contact PC Interrupteur MARCHE/ARRÊT Électronique Pré-opération SuiteUtiliser LA Cloueuse FonctionnementEntretien RangementAttaches Service TechniqueEntretien Suite Information SUR LES Attaches InterchangeablesSymptôme Causes possibles Action corrective Guide de dépannagePour pièces de rechange ou assistance technique, appeler Trousses DE Pièces DE Rechange LA Présente Garantie NE Couvre PAS Garantie LimitéeClavadora para Acabado Por información sobre piezas, productos y servicios ÍndiceEspecificaciones DescripciónProposición 65 de California Medidas de SeguridadSímbolos de seguridad Importantes Instrucciones De SeguridadUso y Cuidado de la Herramienta Importantes Instrucciones De Seguridad ContinuaciónSeguridad Personal Seguridad EléctricaNo exponga la herramienta a calor extremo Contenidos DesempaqueEnsamblaje Guarde Estas Instrucciones No LAS DesecheFigura Acoplador rápido GlosarioCaracterísticas Conozca su clavadora de puntillas como un profesionalDiámetro Largo del Recorrido ConfiguraciónLubricación Componentes Mínimos Necesarios Para LA ConexiónInstalación DE LA Punta Antirrayones Configuración ContinuaciónPara Cargar Y Descargar LA Clavadora Ajuste DE LA Penetración DEL ClavoModos DE Funcionamiento Pre-FuncionamientoElemento DE Contacto DE Trabajo WCE Figura Pre-Funcionamiento continuaciónDisparo DE LA Clavadora FuncionamientoAlmacenamiento Funcionamiento continuaciónMantenimiento Información DE Intercambio DE Sujetadores Mantenimiento continuaciónProcedimiento DE Ensamblaje Para LOS Sellos Servicio TécnicoProblema Causa Solución Guía de resolución de problemasSírvase proporcionar la siguiente información No. de Número de Descripción Repuesto Ctd Lista de piezas de repuesto para la clavadora para acabadoLO QUE no Esta Cubierto POR Esta Garantia Garantía Limitada

CHN70200 specifications

The Campbell Hausfeld CHN70200 is a versatile and reliable air compressor designed to meet the needs of both DIY enthusiasts and professionals. This unit offers a blend of performance and efficiency, making it an excellent choice for a variety of applications, such as inflating tires, powering pneumatic tools, and other tasks requiring a dependable source of compressed air.

One of the standout features of the CHN70200 is its powerful 1.0 horsepower motor, which operates on a 120V outlet, making it suitable for home and garage use. With a maximum pressure of 125 PSI, this air compressor delivers a consistent and reliable airflow, ensuring that it can handle a range of demanding tasks with ease. The 2-gallon vertical tank design not only provides ample air storage but also saves valuable floor space, making it a practical choice for tight work environments.

The CHN70200 is equipped with a quick-connect coupler, allowing users to easily attach and detach air hoses and tools. This convenience reduces downtime during tasks, enabling users to stay productive. Additionally, its noise level is relatively low, thanks to its oil-free pump design, which operates quietly and efficiently. This feature is particularly valuable in residential areas where noise restrictions may be a concern.

Moreover, the oil-free pump technology means that maintenance is minimal. Users do not have to worry about oil changes, which translates to lower operating costs and increased longevity for the compressor. This feature, combined with the lightweight and portable design, makes the Campbell Hausfeld CHN70200 a user-friendly option for those on the go.

Safety is also a priority with the CHN70200 as it comes equipped with built-in safety features, including an automatic thermal overload protection switch. This ensures that the compressor will shut off if it overheats, safeguarding the unit and prolonging its lifespan.

In summary, the Campbell Hausfeld CHN70200 air compressor excels in providing portability, efficiency, and ease of use. Its robust construction and user-friendly features make it a reliable choice for a host of applications, ensuring that whether for casual tasks or more intensive projects, users have access to the power they need. With its combination of features, the CHN70200 stands out as a valuable tool for any toolkit.