Delta A08590 instruction manual Know Your Air Compressor Description of Operation

Page 11

OPERATION

Know Your Air Compressor

READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future reference.

Description of Operation

Become familiar with these controls before operating the unit.

On/Auto/Off Switch: Turn this switch ON to provide automatic power to the pressure switch and OFF to remove power at the end of each use.

Pressure Switch: The pressure switch automatically starts the motor when the air tank pressure drops below the factory set "cut-in" pressure. It stops the motor when the air tank pressure reaches the factory set "cut-out" pressure.

On/Auto/Off

Tank Pressure

Switch

Gauge

 

Pressure

Outlet

Pressure

Switch

Gauge

Safety

 

Valve

 

 

Regulator

Safety Valve: If the pressure switch does not shut off the air compressor at its "cut-out" pressure setting, the safety valve will protect against high pressure by "popping out" at its factory set pressure (slightly higher than the pressure switch "cut-out" setting).

Outlet Pressure Gauge: The outlet pressure gauge indicates the air pressure available at the outlet side of the regulator. This pressure is controlled by the regulator and is always less than or equal to the tank pressure.

Tank Pressure Gauge: The tank pressure gauge indicates the reserve air pressure in the tank.

Regulator: Controls the air pressure shown on the outlet pressure gauge. Turn the knob clockwise to increase pressure and counterclockwise to decrease pressure.

Drain Valve: The drain valve is located at the base of the air tank and is used to drain condensation at the end of each use.

Cooling System (not shown): This compressor contains an

Drain

advanced design cooling system. At the heart of this cooling

Valve

 

system is an engineered fan. It is perfectly normal for this fan

 

to blow air through the vent holes in large amounts. You know that the cooling system is working when air is being expelled.

Air Compressor Pump (not shown): Compresses air into the air tank. Working air is not available until the compressor has raised the air tank pressure above that required at the air outlet.

11- ENG

A08590

Image 11
Contents Oil-Free Air Compressor Death or serious injury Safety Guidelines DefinitionsImportant Safety Instructions Death or serious injury Or moderate injuryAlways remain in attendance with What Could HappenAttachments & Accessories Your specific application Electricity. Like any other electricallyRepairs attempted by unqualified To human consumptionHazard Warning Risk from Moving Parts Result in serious burns How To Prevent ItEquip area of operation with a fire extinguisher Transporting CompressorKeep children away from the air compressor at all times Duty Cycle SpecificationsAccessories GlossaryGrounding Pin InstallationLocation of the Air Compressor Volt U.S.A. PlugVoltage and Circuit Protection Extension CordsKnow Your Air Compressor Description of Operation OperationCheck Valve How to StopBefore Starting Before Each Start-UpCustomer Responsibilities MaintenanceHow to Start To Check Safety ValveOutlet Tube Nut Check Valve Service and AdjustmentsTo Replace or Clean Check Valve To Replace Regulator Troubleshooting Being used Problem Cause Correction ENG A08590 Limited Warranty Compresor de Aire Sin Aceite Lesiones serias Definiciones DE Normas DE SeguridadLesiones serias Resultar en lesiones menores o Moderadas Cómo prevenirlo Instrucciones Importantes DE SeguridadQué puede occurrir Cómo prevenirlo Advertencia Riesgo de Explosión29- SP A08590 Advertencia Riesgo de Caída Qué puede occurrir Advertencia Riesgo de Quemaduras Qué puede occurrirAdvertencia Riesgo de Partes Móviles Qué puede occurrir Advertencia Riesgo de Operación Lasegura Qué puede occurrir Accesorios GlosarioCiclo DE Servicio EspecificacionesUso local InstalaciónEnchufe de 120 V, EE.UU Protección del voltaje y del circuito Cables de extensión eléctricaDescripción de operaciones OperaciónConozca su compresor de aire Procedimiento para el asentamiento Cómo utilizar su unidadAntes de poner en marcha Cómo detenerlaCómo verificar la válvula de seguridad MantenimientoCómo poner en marcha Responsabilidades del clienteTuerca Válvula reguladora Servicio Y AjustesPara reemplazar o limpiar la válvula reguladora Originando un riesgo de ruptura de sus paredes AlmacenajePara reemplazar el regulador Guía DE Duagnóstico DE Problemas Se utiliza un Automático. No use un fusible o Notas AÑO Garantía limitada sobre todos los servicios Garantía LimitadaCompresseur dair sans huile Évité, peut causer des dommages à la Mesures DE Sécurité DéfinitionsConsignes DE Sécurité Importantes Ou la mort Causer des blessures mineures ou MoyennesAvertissement Risque dexplosion ou dincendie Prévention Conserver ces directivesAvertissement Risque de projection dobjets Avertissement Risque déclatementRisque Prévention Avertissement Risque par inhalation Avertissement Risque de choc électriqueAvertissement Risque de chute Prévention Avertissement Risque de brûluresAvertissement Risque relié aux pièces mobiles Avertissement Risque dune utilisation dangereuse Avertissement Risque de dommages à la propriété pendant leTransport du compresseur Spécifications Cycle DE ServiceAccessoires LexiqueMontage DE Lappareil Emplacement du compresseur dairProtection contre la surtension et protection du circuit RallongesDescription du fonctionnement UtilisationFamiliarisez-vous avec votre compresseur dair Avant chaque mise en marche Utilisation de lappareilArrêt de lappareil Avant le démarrageVérification de la soupape de sûreté EntretienMise en marche Responsabilités du clientEntertien ET Réglages Remplacement ou nettoyage de la soupape de retenueRangement Remplacement du régulateurPeut éclater ou exploser DépannageSerrer Est utilisé, ajustez le régulateur Fusible sauté ou coupe-circuit Remarque Garantie Limitée AN Garantie limitée sur tous les accessoires