Delta A08590 instruction manual Before Starting, Before Each Start-Up, How to Stop, Check Valve

Page 12

Check Valve: When the air compressor is operating, the check valve is "open", allowing compressed air to enter the air tank. When the air compressor reaches "cut-out" pressure, the check valve "closes", allowing air pressure to remain inside the air tank.

Check Valve

How to Use Your Unit

How to Stop:

1.Set the On/Auto/Off lever to "OFF".

Before Starting

Break-in Procedure

Risk of Unsafe Operation. Serious damage may result if the following break-in instructions are not closely followed.

This procedure is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced.

1.Make sure the On/Auto/Off lever is in the "Off" position.

NOTE: Pull coupler back until it clicks to prevent air from escaping through the quick connect.

2.Plug the power cord into the correct branch circuit receptacle. (Refer to Voltage and Circuit Protection paragraph in the Installation section of this manual.)

3.Open the drain valve fully (counterclockwise) to permit air to escape and prevent air pressure build up in the air tank during the break-in period.

4.Move the On/Auto/Off lever to "On/Auto" position. The compressor will start.

5.Run the compressor for 15 minutes. Make sure the drain valve is open and there is minimal air pressure build-up in tank.

6.After 15 minutes, close the drain valve (clockwise). The air receiver will fill to "cut-out" pressure and the motor will stop.

The compressor is now ready for use.

Before Each Start-Up:

1.Place On/Auto/Off lever to "OFF".

2.Pull regulator knob out, turn counterclockwise until it stops. Push knob in to lock in place.

3.Attach hose and accessories. NOTE: The hose or accessory will require a quick connect plug if the air outlet is equipped with a quick connect socket.

Too much air pressure causes a hazardous risk of bursting. Check the manufacturer’s maximum pressure rating for air tools and accessories. The regulator outlet pressure must never exceed the maximum pressure rating.

A08590

12- ENG

Image 12
Contents Oil-Free Air Compressor Safety Guidelines Definitions Important Safety InstructionsDeath or serious injury Or moderate injury Death or serious injuryWhat Could Happen Always remain in attendance withAttachments & Accessories Electricity. Like any other electrically Repairs attempted by unqualifiedTo human consumption Your specific applicationResult in serious burns How To Prevent It Hazard Warning Risk from Moving PartsTransporting Compressor Keep children away from the air compressor at all timesEquip area of operation with a fire extinguisher Specifications AccessoriesGlossary Duty CycleInstallation Location of the Air CompressorVolt U.S.A. Plug Grounding PinExtension Cords Voltage and Circuit ProtectionOperation Know Your Air Compressor Description of OperationHow to Stop Before StartingBefore Each Start-Up Check ValveMaintenance How to StartTo Check Safety Valve Customer ResponsibilitiesService and Adjustments To Replace or Clean Check ValveOutlet Tube Nut Check Valve To Replace Regulator Troubleshooting Being used Problem Cause Correction ENG A08590 Limited Warranty Compresor de Aire Sin Aceite Definiciones DE Normas DE Seguridad Lesiones serias Resultar en lesiones menores o ModeradasLesiones serias Instrucciones Importantes DE Seguridad Cómo prevenirloAdvertencia Riesgo de Explosión Qué puede occurrir Cómo prevenirlo29- SP A08590 Advertencia Riesgo de Quemaduras Qué puede occurrir Advertencia Riesgo de Partes Móviles Qué puede occurrirAdvertencia Riesgo de Caída Qué puede occurrir Advertencia Riesgo de Operación Lasegura Qué puede occurrir Glosario Ciclo DE ServicioEspecificaciones AccesoriosInstalación Enchufe de 120 V, EE.UUUso local Cables de extensión eléctrica Protección del voltaje y del circuitoOperación Conozca su compresor de aireDescripción de operaciones Cómo utilizar su unidad Antes de poner en marchaCómo detenerla Procedimiento para el asentamientoMantenimiento Cómo poner en marchaResponsabilidades del cliente Cómo verificar la válvula de seguridadServicio Y Ajustes Para reemplazar o limpiar la válvula reguladoraTuerca Válvula reguladora Almacenaje Para reemplazar el reguladorOriginando un riesgo de ruptura de sus paredes Guía DE Duagnóstico DE Problemas Se utiliza un Automático. No use un fusible o Notas Garantía Limitada AÑO Garantía limitada sobre todos los serviciosCompresseur dair sans huile Mesures DE Sécurité Définitions Consignes DE Sécurité ImportantesOu la mort Causer des blessures mineures ou Moyennes Évité, peut causer des dommages à laConserver ces directives Avertissement Risque dexplosion ou dincendie PréventionAvertissement Risque déclatement Risque PréventionAvertissement Risque de projection dobjets Avertissement Risque de choc électrique Avertissement Risque par inhalationAvertissement Risque de brûlures Avertissement Risque relié aux pièces mobilesAvertissement Risque de chute Prévention Avertissement Risque de dommages à la propriété pendant le Transport du compresseurAvertissement Risque dune utilisation dangereuse Cycle DE Service AccessoiresLexique SpécificationsEmplacement du compresseur dair Montage DE LappareilRallonges Protection contre la surtension et protection du circuitUtilisation Familiarisez-vous avec votre compresseur dairDescription du fonctionnement Utilisation de lappareil Arrêt de lappareilAvant le démarrage Avant chaque mise en marcheEntretien Mise en marcheResponsabilités du client Vérification de la soupape de sûretéRemplacement ou nettoyage de la soupape de retenue Entertien ET RéglagesRemplacement du régulateur RangementDépannage SerrerPeut éclater ou exploser Est utilisé, ajustez le régulateur Fusible sauté ou coupe-circuit Remarque AN Garantie limitée sur tous les accessoires Garantie Limitée