Sterling 882.01749.00 manual Screw Recovery Time

Page 37

Screw Recovery Time.

The screw recovery time is the estimated screw recovery time, and is used as the initial value for validating the recipe. Actual screw recovery times as measured by the presence of the screw recovery signal, are used to fine-tune the feed rate during operation. The estimated time must be at least ½ of the actual recovery time. If less than ½, the feeder will interpret the recovery signal as a purge cycle.

Calibration weight.

Calibration weight is determined from chart 5.1, and is dependant on the disc installed in the feeder. This weight is the amount of standard density material dispensed by the feeder during one revolution of the disc. This weight is used as the initial value for recipe validation and feed rate calculation. If samples are not weighed as described in the next section, this value is used during operation. The weight can be entered in ounces or grams. The unit of measure is changed by pressing the units button at the middle right of the screen. Changing the unit of measure will NOT change the value displayed on the screen. The value initially displayed is the weight which would result in a motor speed of 25%. The valid range of values would then be ¼ to 5 times this initial value.

Additive Sample weighing.

Weighing samples of additive provides for more precise control of feed rate. Up to 5 samples can be weighed. All weights entered are averaged to arrive at a value to be used during operation. The weighing process may be skipped altogether, in which case the calibration weight is used for calculations of feed rate. See the section Weight Calibration at the end of this section.

882.01749.00

37 of 93

Image 37
Contents Digital Dosing Disc Additive Feeders Write Down Your Serial Numbers Here For Future Reference Unpacking and Inspection Shipping InfoTable of Contents Appendix a Basic Parameter Settings How to Use This Manual SafetyResponsibility General Safety RegulationsOperate this equipment within design specifications Introduction Functional DescriptionDuo Dual Station Digital Dosing Feeder A250 ControllerUnpacking Quick Start-Up GuideFeeder Configuration Injection Molding Encoder Pulses Motor and alarm utilty selectionPage Additive % Injection moldingShot Size Calibration weight Screw Recovery TimeDD Pellet Discs DP Powder Discs DT Pellet & Regrind DiscsDisc Additive Sample weighingRPM Page Recipe Setup for Simple Extrusion Throughput Feeder Configuration Extrusion follower 8400 Bodine Motor and alarm utilty selection Recipe Setup for Simple Extrusion Throughput Speed Disc Calibration Number Thickness Weight CalibrationScreen Screen Screen Installation Installation and Operation882.01749.00 TB #51 TB #54 Initial Operation Recipe Menu RecipesEnter / Edit Recipes Screw Recovery Time Simple Extrusion Recipe Extrusion Follower Recipe Throughput Speed Calibration Screen Screen Prerequisites Status screensCommon Elements Buttons Disc Motor Indicator Speed Status IndicatorPress Signal Indicator Throughput Screen Totalizer ScreenMotor Speed Screen Manual Run / Jog Screen Screw Recovery Times Screen Injection onlySystem Setup Menu Configuration NavigationSystem Setup Navigation Buttons 882.01749.00 882.01749.00 Feeder Type Maximum Motor Speed Encoder PulsesManufacturer Motor Color Black & silver Speed Alarm Drive TuningDefault Additive Measure Default Shot Size / Throughput Measure Injection Press Additive / Virgin Material Sensor Minimum Press Signal. Extrusion Follower only Press Signal Type. Extrusion Follower onlyMaximum Press Signal. Extrusion Follower only Passwords Screen Digital I/O Monitor Level switches probes Optional FeaturesAnalog / Encoder Monitor Level Sensor Adjustment Screw Optional Additive Hoppers Communication Protocol Interfaces882.01749.00 Virgin Material Supply Hoppers Preventative Maintenance Intervals MaintenanceDD Dosing Module Pellets Removing the Shear Plate DD dosing Module Installing the shearRemoving the shear Dismantling the Dosing Module Removing the DD Disc and Cleaning the Dosing ModuleInstalling Different Types of Dosing Discs Installing the Dosing ModuleDT Dosing Module Pellets and Some Regrind Removing/Replacing the Wiper in the DT Dosing Station Removing the DT Disc and cleaning the dosing station DP Powder Dosing Module Removing/Replacing the DT Disc & Cleaning the Dosing Station Removing the DP Disc and Cleaning the Dosing Station DD Discs Exchangeable Dosing ModulesDT Discs DP DiscsQTY Description Spare Parts DD Dosing UnitsQTY Description DT Dosing UnitsQTY Description DP Dosing UnitsAdditional Spare Parts DD/DT/DPRecipe Formulas Appendix a Basic Parameter SettingsDisc Appendix B Disc Sizing GuidesDisc Min/Max Single Station Digital Dosing Feeder Appendix C DrawingsDuo Digital Dosing Feeder Electrical Schematics of A250 Controller 882.01749.00 Replacement Motor Assembly Part Numbers Appendix D Spare Parts ListDosing Disc/Shear Order Numbers Sterling, Inc Appendix E Technical Assistance882.01749.00