This screen configures the maximum speed of the press and the analog signal associated with that speed. Press the top number to enter the maximum speed, using the screen keyboard, in RPM for the press. The voltage associated with that speed can either be entered manually by pressing the value and entering the value on the keyboard, or by pressing the number at the lower left to read the voltage level currently being sent by the press. The unit of measure, A or V, is determined by the selection made on the Press Signal Type screen.
Note: The Minimum & maximum press signal values are used to calculate the relationship between input signal and extruder speed. Operation at speeds below the minimum and above the maximum are possible, subject to input signal limits. See appendix # for examples.
Passwords Screen.
The passwords screen allow the entry of Operator & Setup passwords. By default, these are set to 0, which disables the password requirement. Setting the password to a
882.01749.00 | 61 of 93 |