4-7 Removing the “DP” Disc and Cleaning the Dosing Station
1.Turn the control unit “Off”.
2.Disconnect the power supply.
3.Open the toggle latches.
4.Remove the dosing hopper (D).
5.Empty the dosing station.
6.Remove the profile clamp (C).
7.Remove the dosing hopper assembly (A and B).
8.Remove the wiper and traverse as described above.
9.Remove the four screws from the metering disc and lift the disc from the dosing unit housing.
10.Clean the components with a cotton cloth.
11.Clean the dosing hopper (A and B) in soapy water.
12.Dry all parts thoroughly.
13.Install the dosing hopper on the dosing module (locating the guide pin).
14.Install the profile clamp and tighten the screw.
15.Mount the dosing housing onto the dosing motor.
16.Close the toggle latches, securing the dosing module to the motor assembly.
882.01749.00 | 78 of 93 |