Drive Tuning.

The drive tuning screen is provided as an aid to tuning the drive to match the motor and load of the A250 feeder. Pressing the “Min” button will send the minimum drive signal to the controller. Pressing the “Max” button will send the maximum drive signal to the controller. Pressing the “Stop” button (or leaving this screen) will terminate any signal sent to the controller. The numbers on the left are the target min/max values. The numbers on the right are the actual speed values. A small screwdriver, preferably non-metallic, is needed to tune the drive. Tune the drive as follows:

Speed Alarm

The reaction to deviations from the commanded speed are controlled via this screen. Speed deviation specifies the window within which the motor speed must be for normal operation. The Alarm Delay specifies the minimum time the speed must be outside this window before generating an alarm. For example, if the default values are used and the commanded speed is 5 RPM, the controller will alarm if the speed is less than

4.75RPM or more than 5.25 RPM for at least 2 seconds. The specific response to the alarm condition can be selected by pressing the button in the lower left corner as follows:

Take no action. See Status screens for indicator.

Activate alarm screen & alarm output on PLC.

882.01749.00

56 of 93

Image 56
Contents Digital Dosing Disc Additive Feeders Write Down Your Serial Numbers Here For Future Reference Shipping Info Unpacking and InspectionTable of Contents Appendix a Basic Parameter Settings Safety How to Use This ManualGeneral Safety Regulations ResponsibilityOperate this equipment within design specifications Functional Description IntroductionA250 Controller Duo Dual Station Digital Dosing FeederQuick Start-Up Guide UnpackingFeeder Configuration Injection Molding Motor and alarm utilty selection Encoder PulsesPage Shot Size Injection moldingAdditive % DD Pellet Discs Screw Recovery TimeCalibration weight DT Pellet & Regrind Discs DP Powder DiscsDisc Additive Sample weighingRPM Page Recipe Setup for Simple Extrusion Throughput Feeder Configuration Extrusion follower 8400 Bodine Motor and alarm utilty selection Recipe Setup for Simple Extrusion Throughput Speed Weight Calibration Disc Calibration Number ThicknessScreen Screen Screen Installation and Operation Installation882.01749.00 TB #51 TB #54 Initial Operation Recipes Recipe MenuEnter / Edit Recipes Screw Recovery Time Simple Extrusion Recipe Extrusion Follower Recipe Throughput Speed Calibration Screen Screen Status screens PrerequisitesCommon Elements Buttons Press Signal Indicator Speed Status IndicatorDisc Motor Indicator Motor Speed Screen Totalizer ScreenThroughput Screen Screw Recovery Times Screen Injection only Manual Run / Jog ScreenConfiguration Navigation System Setup MenuSystem Setup Navigation Buttons 882.01749.00 882.01749.00 Feeder Type Manufacturer Motor Color Encoder PulsesMaximum Motor Speed Black & silver Drive Tuning Speed AlarmDefault Additive Measure Default Shot Size / Throughput Measure Injection Press Additive / Virgin Material Sensor Maximum Press Signal. Extrusion Follower only Press Signal Type. Extrusion Follower onlyMinimum Press Signal. Extrusion Follower only Passwords Screen Digital I/O Monitor Analog / Encoder Monitor Optional FeaturesLevel switches probes Level Sensor Adjustment Screw Communication Protocol Interfaces Optional Additive Hoppers882.01749.00 Virgin Material Supply Hoppers Maintenance Preventative Maintenance IntervalsDD Dosing Module Pellets Removing the shear Installing the shearRemoving the Shear Plate DD dosing Module Removing the DD Disc and Cleaning the Dosing Module Dismantling the Dosing ModuleInstalling the Dosing Module Installing Different Types of Dosing DiscsDT Dosing Module Pellets and Some Regrind Removing/Replacing the Wiper in the DT Dosing Station Removing the DT Disc and cleaning the dosing station DP Powder Dosing Module Removing/Replacing the DT Disc & Cleaning the Dosing Station Removing the DP Disc and Cleaning the Dosing Station Exchangeable Dosing Modules DD DiscsDT Discs DP DiscsSpare Parts DD Dosing Units QTY DescriptionDT Dosing Units QTY DescriptionDP Dosing Units QTY DescriptionDD/DT/DP Additional Spare PartsAppendix a Basic Parameter Settings Recipe FormulasAppendix B Disc Sizing Guides DiscDisc Min/Max Appendix C Drawings Single Station Digital Dosing FeederDuo Digital Dosing Feeder Electrical Schematics of A250 Controller 882.01749.00 Dosing Disc/Shear Order Numbers Appendix D Spare Parts ListReplacement Motor Assembly Part Numbers Appendix E Technical Assistance Sterling, Inc882.01749.00