Sterling 882.01749.00 manual Configuration Navigation, System Setup Menu

Page 49

Pressing and holding the Jog button will run the motor at the indicated speed for as long as the button is held.

The length of time the motor will run when the Run Motor button is pressed. Adjustable from 0 to 999 seconds. The default is 0 seconds.

Pressing the Run Motor button causes the motor to run for the indicated time.

While the motor is running, it can be stopped by pressing the Stop Motor button.

Pressing the Purge button will cause the feeder to run at the indicated rate for the duration of the next screw recovery signal. The purge mode will be cancelled at the end of the screw recovery signal or as noted below.

Pressing the Purge button when purge mode is active will cancel purge mode.

Configuration.

Navigation.

The top level of System setup navigation is the System Setup Menu:

System Setup Menu

The configuration screens are grouped by similar function. Each of the buttons on the System Setup Menu screen will navigate to the 1st screen of each group. From each configuration screen, any of the following screens can be reached:

882.01749.00

49 of 93

Image 49
Contents Digital Dosing Disc Additive Feeders Write Down Your Serial Numbers Here For Future Reference Unpacking and Inspection Shipping InfoTable of Contents Appendix a Basic Parameter Settings How to Use This Manual SafetyResponsibility General Safety RegulationsOperate this equipment within design specifications Introduction Functional DescriptionDuo Dual Station Digital Dosing Feeder A250 ControllerUnpacking Quick Start-Up GuideFeeder Configuration Injection Molding Encoder Pulses Motor and alarm utilty selectionPage Additive % Injection moldingShot Size Calibration weight Screw Recovery TimeDD Pellet Discs DP Powder Discs DT Pellet & Regrind DiscsDisc Additive Sample weighingRPM Page Recipe Setup for Simple Extrusion Throughput Feeder Configuration Extrusion follower 8400 Bodine Motor and alarm utilty selection Recipe Setup for Simple Extrusion Throughput Speed Disc Calibration Number Thickness Weight CalibrationScreen Screen Screen Installation Installation and Operation882.01749.00 TB #51 TB #54 Initial Operation Recipe Menu RecipesEnter / Edit Recipes Screw Recovery Time Simple Extrusion Recipe Extrusion Follower Recipe Throughput Speed Calibration Screen Screen Prerequisites Status screensCommon Elements Buttons Disc Motor Indicator Speed Status IndicatorPress Signal Indicator Throughput Screen Totalizer ScreenMotor Speed Screen Manual Run / Jog Screen Screw Recovery Times Screen Injection onlySystem Setup Menu Configuration NavigationSystem Setup Navigation Buttons 882.01749.00 882.01749.00 Feeder Type Maximum Motor Speed Encoder PulsesManufacturer Motor Color Black & silver Speed Alarm Drive TuningDefault Additive Measure Default Shot Size / Throughput Measure Injection Press Additive / Virgin Material Sensor Minimum Press Signal. Extrusion Follower only Press Signal Type. Extrusion Follower onlyMaximum Press Signal. Extrusion Follower only Passwords Screen Digital I/O Monitor Level switches probes Optional FeaturesAnalog / Encoder Monitor Level Sensor Adjustment Screw Optional Additive Hoppers Communication Protocol Interfaces882.01749.00 Virgin Material Supply Hoppers Preventative Maintenance Intervals MaintenanceDD Dosing Module Pellets Removing the Shear Plate DD dosing Module Installing the shearRemoving the shear Dismantling the Dosing Module Removing the DD Disc and Cleaning the Dosing ModuleInstalling Different Types of Dosing Discs Installing the Dosing ModuleDT Dosing Module Pellets and Some Regrind Removing/Replacing the Wiper in the DT Dosing Station Removing the DT Disc and cleaning the dosing station DP Powder Dosing Module Removing/Replacing the DT Disc & Cleaning the Dosing Station Removing the DP Disc and Cleaning the Dosing Station DD Discs Exchangeable Dosing ModulesDT Discs DP DiscsQTY Description Spare Parts DD Dosing UnitsQTY Description DT Dosing UnitsQTY Description DP Dosing UnitsAdditional Spare Parts DD/DT/DPRecipe Formulas Appendix a Basic Parameter SettingsDisc Appendix B Disc Sizing GuidesDisc Min/Max Single Station Digital Dosing Feeder Appendix C DrawingsDuo Digital Dosing Feeder Electrical Schematics of A250 Controller 882.01749.00 Replacement Motor Assembly Part Numbers Appendix D Spare Parts ListDosing Disc/Shear Order Numbers Sterling, Inc Appendix E Technical Assistance882.01749.00