Hobart Welding Products OM-474 manual Symbol Usage, Arc Welding Hazards, Electric Shock can kill

Page 5

SECTION 1 – SAFETY PRECAUTIONS - READ BEFORE USING

rom _nd_11/98

1-1. Symbol Usage

Means Warning! Watch Out! There are possible hazards with this procedure! The possible hazards are shown in the adjoining symbols.

Y Marks a special safety message.

This group of symbols means Warning! Watch Out! possible

ELECTRIC SHOCK, MOVING PARTS, and HOT PARTS hazards.

 

. Means “Note”; not safety related.

Consult symbols and related instructions below for necessary actions

to avoid the hazards.

1-2. Arc Welding Hazards

YThe symbols shown below are used throughout this manual to call attention to and identify possible hazards. When you see the symbol, watch out, and follow the related instructions to avoid the hazard. The safety information given below is only a summary of the more complete safety information found in the Safety Standards listed in Section 1-5. Read and follow all Safety Standards.

YOnly qualified persons should install, operate, maintain, and repair this unit.

YDuring operation, keep everybody, especially children, away.

ELECTRIC SHOCK can kill.

Touching live electrical parts can cause fatal shocks or severe burns. The electrode and work circuit is electrically live whenever the output is on. The input power circuit and machine internal circuits are also

live when power is on. In semiautomatic or automatic wire welding, the wire, wire reel, drive roll housing, and all metal parts touching the welding wire are electrically live. Incorrectly installed or improperly grounded equipment is a hazard.

DDo not touch live electrical parts.

DWear dry, hole-free insulating gloves and body protection.

DInsulate yourself from work and ground using dry insulating mats or covers big enough to prevent any physical contact with the work or ground.

DDo not use AC output in damp areas, if movement is confined, or if there is a danger of falling.

DUse AC output ONLY if required for the welding process.

DIf AC output is required, use remote output control if present on unit.

DDisconnect input power or stop engine before installing or servicing this equipment. Lockout/tagout input power according to OSHA 29 CFR 1910.147 (see Safety Standards).

DProperly install and ground this equipment according to its Owner’s Manual and national, state, and local codes.

DAlways verify the supply ground – check and be sure that input power cord ground wire is properly connected to ground terminal in disconnect box or that cord plug is connected to a properly grounded receptacle outlet.

DWhen making input connections, attach proper grounding conduc- tor first – double-check connections.

DFrequently inspect input power cord for damage or bare wiring – replace cord immediately if damaged – bare wiring can kill.

DTurn off all equipment when not in use.

DDo not use worn, damaged, undersized, or poorly spliced cables.

DDo not drape cables over your body.

DIf earth grounding of the workpiece is required, ground it directly with a separate cable.

DDo not touch electrode if you are in contact with the work, ground, or another electrode from a different machine.

DUse only well-maintained equipment. Repair or replace damaged parts at once. Maintain unit according to manual.

DWear a safety harness if working above floor level.

DKeep all panels and covers securely in place.

DClamp work cable with good metal-to-metal contact to workpiece or worktable as near the weld as practical.

DInsulate work clamp when not connected to workpiece to prevent contact with any metal object.

DDo not connect more than one electrode or work cable to any single weld output terminal.

SIGNIFICANT DC VOLTAGE exists after stopping engine on inverters.

DStop engine on inverter and discharge input capacitors according to instructions in Maintenance Section before touching any parts.

ARC RAYS can burn eyes and skin.

Arc rays from the welding process produce intense visible and invisible (ultraviolet and infrared) rays that can burn eyes and skin. Sparks fly off from the weld.

DWear a welding helmet fitted with a proper shade of filter to protect your face and eyes from arc rays and sparks when welding or watching (see ANSI Z49.1 and Z87.1 listed in Safety Standards).

DWear approved safety glasses with side shields under your helmet.

DUse protective screens or barriers to protect others from flash and glare; warn others not to watch the arc.

DWear protective clothing made from durable, flame-resistant mate- rial (wool and leather) and foot protection.

FUMES AND GASES can be hazardous.

Welding produces fumes and gases. Breathing these fumes and gases can be hazardous to your health.

DKeep your head out of the fumes. Do not breathe the fumes.

DIf inside, ventilate the area and/or use exhaust at the arc to remove welding fumes and gases.

DIf ventilation is poor, use an approved air-supplied respirator.

DRead the Material Safety Data Sheets (MSDSs) and the manufacturer’s instructions for metals, consumables, coatings, cleaners, and degreasers.

DWork in a confined space only if it is well ventilated, or while wearing an air-supplied respirator. Always have a trained watch- person nearby. Welding fumes and gases can displace air and lower the oxygen level causing injury or death. Be sure the breath- ing air is safe.

DDo not weld in locations near degreasing, cleaning, or spraying op- erations. The heat and rays of the arc can react with vapors to form highly toxic and irritating gases.

DDo not weld on coated metals, such as galvanized, lead, or cadmium plated steel, unless the coating is removed from the weld area, the area is well ventilated, and if necessary, while wearing an air-supplied respirator. The coatings and any metals containing these elements can give off toxic fumes if welded.

OM-474 Page 1

Image 5
Contents Processes OM-474Description JulyFrom Hobart to You Table of Contents Page Arc Welding Hazards Symbol UsageElectric Shock can kill ARC Rays can burn eyes and skinEngine Hazards Moving Parts can cause injury Battery Explosion can BlindEngine Exhaust Gases can kill Engine Heat can cause fireEMF Information Principal Safety StandardsRadiation can cause interference ARC Welding can cause interferenceConsignes DE Sécurité Lire Avant Utilisation Signification des symbolesUN Choc Électrique peut tuer LES Fumées ET LES GAZ peuvent être dangereuxDES Particules Volantes peuvent blesser les yeux LE Soudage peut provoquer un in- cendie ou une explosionDES Pièces Chaudes peuvent provoquer des brûlures graves LE Bruit peut affecter l’ouïe’EXPLOSION DE LA Batterie peut DES Organes Mobiles peuvent provoquer des blessuresLA Chaleur DU Moteur peut pro- voquer un incendie LA Chute DE L’APPAREIL peut blesserInformation sur les champs électromagnétiques Principales normes de sécuritéLE Soudage À L’ARC risque de provoquer des interférences Consignes relatives aux stimulateurs cardiaquesSymbols And Definitions SpecificationsWeld, Power, And Engine Specifications DefinitionsDimensions Dimensions, Weights, And Operating AnglesWeight Fuel ConsumptionDuty Cycle And Overheating AC Auxiliary Power60% Duty Cycle At 350 Amperes Minutes Welding12.5 KVA/KW Three-Phase Auxiliary Power Plant No Weld Load Optional AC Power Plant Curves5 KVA/KW Single-Phase Auxiliary Power Plant No Weld Load DC Volts CC/DC Standard Volt-Ampere CurvesAC Amperes CV/DC Models with Optional CV-3 Module 100 Ranges 190-Max 110-270Connecting The Battery InstallationInstalling Welding Generator Temperatures below 0 F -18C 13 mm Full Diesel Valve Open Installing MufflerEngine Prestart Checks Do not use gasoline. Gasoline will damage engineSelecting Weld Cable Sizes Connecting To Weld Output Terminals100 ft 30 m Or Less 10 100% Duty CycleTerminal Strip 3T Connections Optional Remote 14 Receptacle RC3 Information Optional, See SectionSocket Information Stop engineFront Panel Controls See Section Operating Welding GeneratorDo not switch under load Ampere Range SwitchDescription Of Front Panel Controls See Section Stop engine and fix trouble if either warning light goes onExample Combination remote amperage control Remote Control OptionalVolt Duplex And Optional Gfci Receptacles Operating Auxiliary EquipmentOpen Contact Volt Duplex Receptacle OptionalFront Connecting Optional Auxiliary Power PlantSet Engine Control switch to Run when using auxiliary power Maintenance and Troubleshooting Maintenance Label Do not clean housing with air hose Servicing Air CleanerTo Clean air filter Stop engine and let cool Servicing Fuel SystemTo drain water from fuel system To replace fuel filterEngine Speed No Load Adjusting Engine SpeedIdle Speed Adjustment Changing Engine Oil And Filter If any fuse or circuit breaker Overload ProtectionTroubleshooting Inspecting And Cleaning Optional Spark Arrestor MufflerWelding Trouble RemedyAuxiliary Power Check engine control switch, and replace if necessary Coolant temperature gets too high see SectionEngine See engine manualOM-474 Circuit Diagram For Welding Generator For Standard Models Electrical DiagramsOM-474 193 989-B Wetstacking RUN-IN ProcedureLoad Bank Run-In Procedure Using Load BankDo not touch hot exhaust Run-In Procedure Using Resistance GridBank/grid From flammablesGrounding Generator To Truck Or Trailer Frame Auxiliary Power GuidelinesSelecting Equipment How Much Power Does Equipment Require? Grounding When Supplying Building SystemsEarth ground if supplying Use ground device as stated in electrical codesApproximate Power Requirements For Farm/Home Equipment Approximate Power Requirements For Industrial MotorsIndustrial Motors Rating Starting Watts Running Watts Farm/Home Equipment Rating Starting Watts Running WattsContractor Rating Starting Watts Running Watts Approximate Power Requirements For Contractor EquipmentHow Much Power Can Generator Supply? Power Required To Start MotorSingle-Phase Induction Motor Starting Requirements KVA/HP x HP xWelding Generator Auxiliary Power output circuit Typical Connections To Supply Standby PowerItem 4 is not necessary if circuit Protection is already presentCurrent Load Watts Amperes Selecting Extension Cord Use Shortest Cord Possible101 102 105 104 103 Parts List65 66 Includes Items Dia Part Description Mkgs Quantity PLG9,RC9 PC4 Control Box w/Components Control Box w/Components -4 ItemGenerator Generator -1 Item Panel, Front w/Components Panel, Front w/Components -1 Item Page Support ServiceCall Contact your Distributor forHobart Welding Products