3.Grounded, cord-connected machines intended for use on a supply circuit having a nominal rating between 150 - 250 volts, inclusive:

If the machine is intended for use on a circuit that has an outlet that looks like the one illustrated in Fig. C, the machine will have a grounding plug that looks like the plug illustrated in Fig. C. Make sure the machine is connected to an outlet having the same configuration as the plug. No adapter is available or should be used with this machine. If the machine must be re-connected for use on a different type of electric circuit, the re- connection should be made by qualified service personnel; and after re-connection, the machine should comply with all local codes and ordinances.

GROUNDED OUTLET BOX

CURRENT

CARRYING

PRONGS

GROUNDING BLADE

IS LONGEST OF THE 3 BLADES

Fig. C

EXTENSION CORDS

Use proper extension cords. Make sure your extension cord is in good condition and is a 3-wire extension cord which has a 3-prong grounding type plug and matching receptacle which will accept the machine’s plug. When using an extension cord, be sure to use one heavy enough to carry the current of the machine. An undersized cord will cause a drop in line voltage, resulting in loss of power and overheating. Fig. D-1 or D-2, shows the correct gauge to use depending on the cord length. If in doubt, use the next heavier gauge. The smaller the gauge number, the heavier the cord.

MINIMUM GAUGE EXTENSION CORD

RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC MACHINES

Ampere

 

Total Length

Gauge of

Rating

Volts

of Cord in Feet

Extension Cord

0-6

120

up to 25

18 AWG

0-6

120

25-50

16 AWG

0-6

120

50-100

16 AWG

0-6

120

100-150

14 AWG

6-10

120

up to 25

18 AWG

6-10

120

25-50

16 AWG

6-10

120

50-100

14 AWG

6-10

120

100-150

12 AWG

 

 

 

 

10-12

120

up to 25

16 AWG

10-12

120

25-50

16 AWG

10-12

120

50-100

14 AWG

10-12

120

100-150

12 AWG

 

 

 

 

12-16

120

up to 25

14 AWG

12-16

120

25-50

12 AWG

12-16

120

GREATER THAN 50 FEET NOT RECOMMENDED

 

 

 

 

Fig. D-1

MINIMUM GAUGE EXTENSION CORD

RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC MACHINES

Ampere

 

Total Length

Gauge of

Rating

Volts

of Cord in Feet

Extension Cord

 

 

 

 

0-6

240

up to 50

18 AWG

0-6

240

50-100

16 AWG

0-6

240

100-200

16 AWG

0-6

240

200-300

14 AWG

6-10

240

up to 50

18 AWG

6-10

240

50-100

16 AWG

6-10

240

100-200

14 AWG

6-10

240

200-300

12 AWG

 

 

 

 

10-12

240

up to 50

16 AWG

10-12

240

50-100

16 AWG

10-12

240

100-200

14 AWG

10-12

240

200-300

12 AWG

 

 

 

 

12-16

240

up to 50

14 AWG

12-16

240

50-100

12 AWG

12-16

240

GREATER THAN 100 FEET NOT RECOMMENDED

 

 

 

 

Fig. D-2

FUNCTIONAL DESCRIPTION

FOREWORD

The Delta 10” Hybrid Saw (36-714) has a powerful 13/4 HP induction motor that can handle tough cutting operations. This table saw has a maximum depth of cut of 31/8 inches (79mm) at 90 degrees and 21/8 inches (54mm) at 45 degrees. The maximum dado width with this saw is 13/16 inch (21mm). The saw comes with two cast iron extension wings, one of three fence systems, see-through blade guard and splitter, table insert, equipment mounting hooks, a 10" diameter blade, dust port for 4" hose and miter gage.

NOTICE: THE PHOTO ON THE MANUAL COVER ILLUSTRATES THE CURRENT PRODUCTION MODEL. ALL OTHER ILLUSTRATIONS CONTAINED IN THE MANUAL ARE REPRESENTATIVE ONLY AND MAY NOT DEPICT THE ACTUAL COLOR, LABELING OR ACCESSORIES AND ARE INTENDED TO ILLUSTRATE TECHNIQUE ONLY.

7

Image 7
Contents Delta 10 Hybrid Saw Important Safety Instructions Table of ContentsCalifornia Proposition Safety Guidelines DefinitionsImportant Safety Instructions General Safety RulesStay ALERT, Watch What YOU are DOING, Cutting the Workpiece Without the USE Additional Safety Rules for Table SawsMotor Specifications Power ConnectionsGrounding Instructions Extension Cords Functional DescriptionForeword Carton Contents Unpacking and Cleaning AssemblyAssembly Tools Required Bolting the SAW to Floor Disconnect Machine from Power SourceBlade Tilting and Raising Handwheels Installing Drive Belt Do not Operate the SAW Without Right Table Wing Installed S C O N N E C T M a C H I N E F R O M Power SourceExtension Wings Installing the Switch Installing Your Fence SystemAssembling Blade Guard and Splitter Assembly If alignment is necessary, loosen the two screws Aligning Splitter with Blade SAW BladeInstalling Dust Port Installing Table InsertAdjusting Table Insert Installing Tool HoldersStarting and Stopping SAW Locking Switch in OFF PositionOperation Assembling Miter GageBlade Alignment Checking Blade AlignmentBacklash Adjustments Adjusting Blade AlignmentCommon Sawing Operations Miter Gage Operation and AdjustmentCROSS-CUTTING Never USE the Fence AS a CUT-OFF Gage When CROSS-CUTTINGConstructing a Push Stick RippingGuard Removed for CLARITY. Always USE the Guard Using Moulding Cutterhead Using Auxiliary Wood Facing on RIP Fence Using Dado HeadPower Tool Institute TroubleshootingConstructing a Featherboard Constructing a Push Stick PushstickService MaintenanceWarranty AccessoriesPage Page Canadian PORTER-CABLE Delta Service Centers