Graco 3A2495C important safety instructions Fan Air Adjustment Valve Repair

Page 48

Repair

Fan Air Adjustment Valve Repair

1.See Prepare the Gun for Service, page 39.

2.Place a wrench on the flats of the valve assembly (30) and unscrew it from the handle (16).

NOTE: You may replace the valve as an assembly (go to step 9) or as individual parts (steps 3-9).

3.Remove the retaining ring (30d).

4.Turn the valve shaft (30b) counterclockwise until it comes free from the valve housing (30a).

5.Remove the o-ring (30c).

6.Clean all parts and inspect for wear or damage.

NOTE: Use non-silicone grease, Part No. 111265. Do not over-lubricate.

7.When reassembling the fan air valve (30), lightly lubricate the valve threads and screw the shaft (30b) fully into the housing (30a) until bottomed. Install the o-ring (30c*), lubricate, and unscrew the valve stem until the o-ring enters the housing.

8.Reassemble the retaining ring (30d). Unscrew the valve stem from the housing until it is stopped by the retaining ring.

9.Screw the valve assembly (30) into the gun handle (16), using a wrench on the flats of the housing. Torque to 15 in-lb (1.7 N•m).

Figure 37 Fan Air Adjustment Valve

48

3A2495C

Image 48
Contents Important Safety Instructions InstructionsContents Smart Display Standard Display II 2 GFIRE, EXPLOSION, and Electric Shock Hazard Skin Injection Hazard Equipment Misuse Hazard Gun Overview How the Electrostatic AA Spray Gun WorksChart, page 62, for avail Setup Checklist,Description Purpose See Spray Tip SelectionOperating Mode Bar Graph Smart GunsError Display Key for Figs Description Purpose Description Purpose Diagnostic Mode Alternator Speed Hertz Screen Installation Ventilate the Spray BoothAir Supply Line Fluid Supply LineHose Typical Installation Key Description NON-HAZARDOUS AreaGun Setup Gun Setup ChecklistGun Setup LED Indicator Colors Description Pressure DropGrounding Key to Figs Ground the Operator Ground the Gun Check Gun Electrical Grounding Flush Before Using Equipment Check Fluid ResistivityCheck Fluid Viscosity Fluid Resistivity Levels Megohms-cmPressure Relief Procedure OperationStartup ShutdownMaintenance FlushingClean the Gun Daily Maintenance Daily System Care Check Gun Electrical Grounding,Electrical Tests Test Gun ResistanceTest Power Supply Resistance Alternator Removal and Replacement,Test Gun Barrel Resistance Troubleshooting Spray Pattern TroubleshootingProblem Cause Solution Clean the Gun Daily,Gun Operation Troubleshooting Replacement, Power Supply RemovalReplacement, page 45 Test Gun Resistance,See Clean the Gun Daily, Replacement, page 52Prepare the Gun for Service RepairAir Cap, Spray Tip, and Fluid Seat Housing Replacement See Prepare the Gun for Service,Electrode Replacement See Test Gun Resistance,Fluid Filter Replacement Fluid Tube Removal and ReplacementGun Barrel Installation Gun Barrel RemovalFluid Needle Replacement Remove Cap and SpringsPower Supply Removal and Replacement See Prepare the Gun for Service, See Gun Barrel Removal,Alternator Removal and Replacement Alternator Fan Air Adjustment Valve Repair Fan Air Adjustment ValveAtomizing Air Adjustment Valve Repair ES On-Off Valve Repair See Gun Barrel Installation, Air Valve RepairSmart Module Replacement Smart ModuleAir Swivel and Exhaust Valve Replacement Air Inlet Fitting and Air Exhaust ValveStandard Air-Assisted Spray Gun Assembly PartsDescription Qty Smart Air-Assisted Spray Gun Assembly See Smart Module Assembly Alternator Assembly Part No N664 Alternator AssemblyES On-Off Valve Assembly Part No N632 ES On-Off Valve AssemblyFan Air Valve Assembly Part No N634 Fan Air Valve AssemblyAir Cap Assembly Smart Module Assembly Spray Tip Selection Chart AEM Fine Finish Spray TipsAEF Fine Finish Pre-Orifice Spray Tips Orifice Fluid OutputOz/min l/min 41 bar MPa Bar Spray TipRepair Kits, Related Manuals, and Accessories Gun AccessoriesSystem Accessories Test EquipmentOperator Accessories HosesDimensions Gun Model In. mm Weight, oz gTechnical Data Graco Pro Xp Warranty Graco Information