Graco 3A2495C important safety instructions Alternator Speed Hertz Screen

Page 14

Gun Overview

Alternator Speed (Hertz) Screen

The Alternator Speed (Hertz) Screen is the third screen in the Diagnostic Mode. See Fig. 8, and Table 1 on page 11. To enter this screen, press the LO SET button while in the Current (microAmperes) Screen.

This screen displays the alternator speed as a 3 digit number (AS), rounded to the nearest 10 Hz. The display is a readout and cannot be changed. If the alternator speed is greater than 999 Hz, the display will show 999.

The Hz indicator lights green to show that you are viewing the Alternator Speed (Hertz) Screen.

Press the LO SET button to advance to the

Low Voltage Lock Screen, page 14. Press and hold for approximately 5 seconds to return to Operating Mode.

Figure 8 Alternator Speed (Hertz) Screen

Low Voltage Lock Screen

The Low Voltage Lock Screen is the fourth screen in the Diagnostic Mode. See Fig. 9, and Table 1 on page 11. To enter this screen, press the LO SET button while in the Alternator Speed (Hertz) Screen.

This screen displays the status of the Low Voltage Lock. If the setting is locked, the lock image (LK) appears to the left of the Lo display (LD). If the setting is unlocked, the lock image does not appear.

To change the lock status, press and hold the LO SET button until the lock image appears or disappears. If the lock is set, the image will also appear on the Low Voltage Setting Screen when in low voltage mode (see Fig. 4).

NOTE: Diagnostic Mode cannot be exited from this screen, because pressing and holding the LO SET button is used to turn the lock on or off. To exit, press LO SET momentarily to return to the Voltage (kiloVolts) Screen, then exit Diagnostic Mode from there.

Figure 9 Low Voltage Lock Screen

14

3A2495C

Image 14
Contents Important Safety Instructions InstructionsContents Smart Display Standard Display II 2 GFIRE, EXPLOSION, and Electric Shock Hazard Skin Injection Hazard Equipment Misuse Hazard Gun Overview How the Electrostatic AA Spray Gun WorksDescription Purpose Chart, page 62, for availSetup Checklist, See Spray Tip SelectionOperating Mode Bar Graph Smart GunsError Display Key for Figs Description Purpose Description Purpose Diagnostic Mode Alternator Speed Hertz Screen Installation Ventilate the Spray BoothHose Air Supply LineFluid Supply Line Typical Installation Key Description NON-HAZARDOUS AreaGun Setup Gun Setup ChecklistGun Setup LED Indicator Colors Description Pressure DropGrounding Key to Figs Ground the Operator Ground the Gun Check Gun Electrical Grounding Check Fluid Viscosity Flush Before Using EquipmentCheck Fluid Resistivity Fluid Resistivity Levels Megohms-cmStartup Pressure Relief ProcedureOperation ShutdownMaintenance FlushingClean the Gun Daily Maintenance Daily System Care Check Gun Electrical Grounding,Electrical Tests Test Gun ResistanceTest Power Supply Resistance Alternator Removal and Replacement,Test Gun Barrel Resistance Problem Cause Solution TroubleshootingSpray Pattern Troubleshooting Clean the Gun Daily,Gun Operation Troubleshooting Replacement, page 45 Replacement,Power Supply Removal Test Gun Resistance,See Clean the Gun Daily, Replacement, page 52Prepare the Gun for Service RepairAir Cap, Spray Tip, and Fluid Seat Housing Replacement See Prepare the Gun for Service,Electrode Replacement See Test Gun Resistance,Fluid Filter Replacement Fluid Tube Removal and ReplacementGun Barrel Installation Gun Barrel RemovalFluid Needle Replacement Remove Cap and SpringsPower Supply Removal and Replacement See Prepare the Gun for Service, See Gun Barrel Removal,Alternator Removal and Replacement Alternator Fan Air Adjustment Valve Repair Fan Air Adjustment ValveAtomizing Air Adjustment Valve Repair ES On-Off Valve Repair See Gun Barrel Installation, Air Valve RepairSmart Module Replacement Smart ModuleAir Swivel and Exhaust Valve Replacement Air Inlet Fitting and Air Exhaust ValveStandard Air-Assisted Spray Gun Assembly PartsDescription Qty Smart Air-Assisted Spray Gun Assembly See Smart Module Assembly Alternator Assembly Part No N664 Alternator AssemblyES On-Off Valve Assembly Part No N632 ES On-Off Valve AssemblyFan Air Valve Assembly Part No N634 Fan Air Valve AssemblyAir Cap Assembly Smart Module Assembly Spray Tip Selection Chart AEM Fine Finish Spray TipsOz/min l/min AEF Fine Finish Pre-Orifice Spray TipsOrifice Fluid Output 41 bar MPa Bar Spray TipSystem Accessories Repair Kits, Related Manuals, and AccessoriesGun Accessories Test EquipmentOperator Accessories HosesDimensions Gun Model In. mm Weight, oz gTechnical Data Graco Pro Xp Warranty Graco Information