Graco 312001R Operation, Trigger Lock, Pressure Relief Procedure, Pressure Control Knob Settings

Page 10

Operation

Operation

Trigger Lock

Always engage the trigger lock when you stop spraying to prevent the gun from being triggered accidentally by hand or if dropped or bumped.

ti8908a

ti8909a

Trigger Locked

Trigger Unlocked

Pressure Relief Procedure

Follow this Pressure Relief Procedure whenever you stop spraying and before cleaning, checking, servicing, or transporting equipment.

1. Turn power switch OFF and unplug power cord.

ti2810a

2.Turn Prime/Spray valve to PRIME to relieve pressure.

ti9346a

3.Hold gun firmly to side of pail. Trigger the gun to relieve pressure.

ti9207a

4. Engage trigger lock.

ti8908a

NOTE: Leave Prime/Spray valve in the PRIME position until you are ready to spray again.

If you suspect the spray tip or hose is clogged or that pressure has not been fully relieved after fol- lowing the steps above, VERY SLOWLY loosen tip guard retaining nut or hose end coupling to relieve pressure gradually, then loosen completely. Clear hose or tip obstruction. Read Unclogging Spray Tip, page 14.

Pressure Control Knob Settings

ti5597a

High Pressure

Low Pressure

Prime/ Rolling

Spray

Spray

Clean

NOTE: To select function, align symbol on pressure control knob with setting indicator on sprayer.

10

312001R

Image 10
Contents Model Models 262800, 262805, 261815Agnum ProX7 Model Series B Series DSpecifications PSIGrounding Fire and Explosion Hazard Skin Injection Hazard Burn Hazard Electric Shock HazardPressurized Aluminum Parts Hazard Moving Parts HazardThermal Overload Grounding and Electric RequirementsFluid supply container follow local code Component Identification ProX Sprayers OnlySG2/SG3 Operation Pressure Relief ProcedurePressure Control Knob Settings Trigger LockOil- or Water-based Materials SetupPrime and Flush Storage Fluid To spray water-based materials after sprayPrime Spraying Techniques Install Tip and Guard on GunAdjust Spray Pressure Preventing Excessive Tip WearTriggering Gun Getting StartedUnclogging Spray Tip Aiming GunSelecting Tip Hole Size Tip SelectionChoosing the Correct Tip Tip Hole SizeTip Fan Width 12 Part Mm from Surface Reversible Tip Selection ChartUnderstanding Tip Number Hole SizePail Flushing Shutdown and CleaningRelieve pressure, Ti9745a Ti8908a Power Flush OpenStop triggering gun. Engage trigger lock Cleaning InstaClean Fluid Filter ProX Sprayers Only Cleaning GunShort Term Storage StorageLong Term Storage Stowing Sprayer Paint Hoses Maintenance and ServiceCaring for Sprayer TipsTroubleshooting Problem Cause SolutionProX7 and ProX9 Insert screw Read Pump does not prime sec Problem Cause Solution See Thermal Overload, Technical Data Magnum X5 Series D Magnum X7 Series CMagnum ProX7 Magnum ProX9 Series B Graco Standard Warranty For Graco Canada Customers