Shutdown and Cleaning

Power Flush

Power flushing is a faster method of flushing. It can only be used after spraying water-based coatings.

1.Relieve pressure, page 10.

2.Remove tip and guard assembly from gun and place in waste pail.

3.Place empty waste and paint pails side by side.

10.Unscrew inlet screen from suction tube. Place inlet screen in waste pail.

ti2040a

11.Connect garden hose to suction tube with Power Flush attachment.

Leave prime tube in waste pail.

ti9726a

4.Lift suction tube and prime tube from paint pail. Let them drain into paint for a while.

5.Place suction and prime tube in waste pail.

6.Turn Pressure Control knob to the Prime/Clean setting.

ti9344a

7.Screw power flush attachment to garden hose. Close valve.

ti9413a

8.Turn on water. Open valve. Rinse paint off suction tube, prime tube and inlet screen.

9.Turn lever to close power flush attachment.

ti9727a

ti2042a

12. Turn power switch ON.

ti5580a

13.Open lever on Power Flush attachment.

OPEN

ti2043a

14.Circulate water through sprayer, into waste pail, for 20 seconds.

15. Turn power switch OFF.

ti2018a

312001R

19

Image 19
Contents Model Series B Series D Models 262800, 262805, 261815Agnum ProX7 ModelPSI SpecificationsGrounding Fire and Explosion Hazard Skin Injection Hazard Moving Parts Hazard Electric Shock HazardPressurized Aluminum Parts Hazard Burn HazardThermal Overload Grounding and Electric RequirementsFluid supply container follow local code ProX Sprayers Only Component IdentificationSG2/SG3 Trigger Lock Pressure Relief ProcedurePressure Control Knob Settings OperationTo spray water-based materials after spray SetupPrime and Flush Storage Fluid Oil- or Water-based MaterialsPrime Preventing Excessive Tip Wear Install Tip and Guard on GunAdjust Spray Pressure Spraying TechniquesAiming Gun Getting StartedUnclogging Spray Tip Triggering GunTip Hole Size Tip SelectionChoosing the Correct Tip Selecting Tip Hole SizeHole Size Reversible Tip Selection ChartUnderstanding Tip Number Tip Fan Width 12 Part Mm from SurfacePail Flushing Shutdown and CleaningRelieve pressure, Ti9745a Ti8908a Open Power FlushStop triggering gun. Engage trigger lock Cleaning Gun Cleaning InstaClean Fluid Filter ProX Sprayers OnlyShort Term Storage StorageLong Term Storage Stowing Sprayer Tips Maintenance and ServiceCaring for Sprayer Paint HosesProblem Cause Solution TroubleshootingProX7 and ProX9 Insert screw Read Pump does not prime sec Problem Cause Solution See Thermal Overload, Magnum X5 Series D Magnum X7 Series C Technical DataMagnum ProX7 Magnum ProX9 Series B For Graco Canada Customers Graco Standard Warranty