Graco 312001R important safety instructions Stop triggering gun. Engage trigger lock

Page 20

Shutdown and Cleaning

NOTE: Step 16 is for returning paint in hose back to paint pail. One 50-ft (15-m) hose holds approxi- mately 1-quart (1-liter) of paint.

16.To preserve paint in hose:

a.Point gun into paint pail.

b.Unlock gun trigger lock.

ti8909a

c. Pull and hold gun trigger.

18.Stop triggering gun. Engage trigger lock.

ti8908a

19.Turn prime/spray valve to Prime.

ti9346a

d. Turn Prime/Spray valve to

SPRAY.

ti9345a

e. Turn power switch ON.

ti5580a

f. Continue to hold gun trigger until you see paint diluted with water starting to come out of gun.

17. While continuing to trigger gun, quickly move gun to redirect spray into waste pail. Continue triggering gun into waste pail until water coming

20. Turn power switch OFF.

21. Turn off garden hose. Close

Power Flush attachment.

22. Unscrew Power Flush

attachment from suction tube.

ti2810a

ti9413a

out of gun is relatively clear.

ti9745a

23. Clean InstaClean Fluid Filter

and gun, page 21.

ti2047a

20

312001R

Image 20
Contents Models 262800, 262805, 261815 Agnum ProX7Model Model Series B Series DSpecifications PSIGrounding Fire and Explosion Hazard Skin Injection Hazard Electric Shock Hazard Pressurized Aluminum Parts HazardBurn Hazard Moving Parts HazardFluid supply container follow local code Grounding and Electric RequirementsThermal Overload Component Identification ProX Sprayers OnlySG2/SG3 Pressure Relief Procedure Pressure Control Knob SettingsOperation Trigger LockSetup Prime and Flush Storage FluidOil- or Water-based Materials To spray water-based materials after sprayPrime Install Tip and Guard on Gun Adjust Spray PressureSpraying Techniques Preventing Excessive Tip WearGetting Started Unclogging Spray TipTriggering Gun Aiming GunTip Selection Choosing the Correct TipSelecting Tip Hole Size Tip Hole SizeReversible Tip Selection Chart Understanding Tip NumberTip Fan Width 12 Part Mm from Surface Hole SizeRelieve pressure, Shutdown and CleaningPail Flushing Ti9745a Ti8908a Power Flush OpenStop triggering gun. Engage trigger lock Cleaning InstaClean Fluid Filter ProX Sprayers Only Cleaning GunLong Term Storage StorageShort Term Storage Stowing Sprayer Maintenance and Service Caring for SprayerPaint Hoses TipsTroubleshooting Problem Cause SolutionProX7 and ProX9 Insert screw Read Pump does not prime sec Problem Cause Solution See Thermal Overload, Technical Data Magnum X5 Series D Magnum X7 Series CMagnum ProX7 Magnum ProX9 Series B Graco Standard Warranty For Graco Canada Customers