Technical Data

Technical Data

 

MAGNUM X5 (Series D)

MAGNUM X7 (Series C)

 

 

 

Working pressure range

0-3000 psi (0-21 MPa, 0-207 bar)

0-3000 psi (0-21 MPa, 0-207 bar)

 

 

 

Electric motor

9.0A (open frame, universal)

9.0A (open frame, universal)

 

 

 

Operating horsepower

1/2

5/8

 

 

 

Maximum delivery (with tip)

0.27 gpm (1.02 lpm)

0.31 gpm (1.17 lpm)

 

 

 

Paint hose

1/4 in. x 25 ft (6.4 mm x 7.5 m)

1/4 in. x 25 ft (6.4 mm x 7.5 m)

 

 

 

Maximum tip hole size

0.015 in. (0.38 mm)

0.017 in. (0.43 mm)

 

 

 

Weight, sprayer only

13.3 lb (6.0 kg)

23.3 lb (10.6 kg)

 

 

 

Weight, sprayer, hose & gun

16.5 lb (7.5 kg)

26.5 lb (12.0 kg)

 

 

 

Dimensions (Upright):

 

 

 

 

 

Length

14.5 in. (36.8 cm)

19.3 in. (49.0 cm)

 

 

 

Width

12.4 in. (31.5 cm)

15.3 in. (38.9 cm)

 

 

 

Height

17.9 in. (45.5 cm)

37.0 in. (94.0 cm)

 

 

 

Dimensions (Folded):

 

 

 

 

 

Length

N/A

19.3 in. (49.0 cm)

 

 

 

Width

N/A

15.3 in. (38.9 cm)

 

 

 

Height

N/A

29.2 in. (74.2 cm)

 

 

 

Power cord

18 AWG, 3-wire, 6 ft (1.8 m)

 

 

Fluid inlet fitting

3/4 in. internal thread (standard garden hose thread)

 

 

Fluid outlet fitting

1/4 NPSM external thread

 

 

Inlet screen (on suction tube)

35 mesh (450 micron)

 

 

Wetted parts, pump & hose

stainless steel, brass, leather, ultra-high molecular weight polyethylene

 

(UHMWPE), carbide, nylon, aluminum, PVC, polypropylene, fluroelastomer

 

 

Wetted parts, gun

aluminum, brass, carbide, nylon, plated steel, stainless steel, UHMWPE, zinc

 

 

Generator requirement

1500 Watt minimum

 

 

Electrical power requirement

120 Vac, 60 Hz, 15A, 1 phase

 

 

Storage temperature range ◆❖

-30° to 160°F (-35° to 71°C)

 

 

Operating temperature range

40° to 115°F (4° to 46°C)

 

 

 

When pump is stored with non-freezing fluid. Pump damage will occur if water or latex paint freezes in

pump.

Damage to plastic parts may result if impact occurs in low temperature conditions.

Changes in paint viscosity at very low or very high temperatures can affect sprayer performance.

30

312001R

Image 30
Contents Model Models 262800, 262805, 261815Agnum ProX7 Model Series B Series DSpecifications PSIGrounding Fire and Explosion Hazard Skin Injection Hazard Burn Hazard Electric Shock HazardPressurized Aluminum Parts Hazard Moving Parts HazardGrounding and Electric Requirements Thermal OverloadFluid supply container follow local code Component Identification ProX Sprayers OnlySG2/SG3 Operation Pressure Relief ProcedurePressure Control Knob Settings Trigger LockOil- or Water-based Materials SetupPrime and Flush Storage Fluid To spray water-based materials after sprayPrime Spraying Techniques Install Tip and Guard on GunAdjust Spray Pressure Preventing Excessive Tip WearTriggering Gun Getting StartedUnclogging Spray Tip Aiming GunSelecting Tip Hole Size Tip SelectionChoosing the Correct Tip Tip Hole SizeTip Fan Width 12 Part Mm from Surface Reversible Tip Selection ChartUnderstanding Tip Number Hole SizeShutdown and Cleaning Pail FlushingRelieve pressure, Ti9745a Ti8908a Power Flush OpenStop triggering gun. Engage trigger lock Cleaning InstaClean Fluid Filter ProX Sprayers Only Cleaning GunStorage Short Term StorageLong Term Storage Stowing Sprayer Paint Hoses Maintenance and ServiceCaring for Sprayer TipsTroubleshooting Problem Cause SolutionProX7 and ProX9 Insert screw Read Pump does not prime sec Problem Cause Solution See Thermal Overload, Technical Data Magnum X5 Series D Magnum X7 Series CMagnum ProX7 Magnum ProX9 Series B Graco Standard Warranty For Graco Canada Customers