Graco 312001R important safety instructions See Thermal Overload

Page 29

 

 

Troubleshooting

 

 

 

Problem

Cause

Solution

 

 

 

 

 

 

Fan pattern varies dramatically

Pressure control switch is worn

Take sprayer to Graco/MAGNUM

while spraying.

and causing excessive pressure

authorized service center.

OR

variation.

 

 

 

Sprayer does not turn on promptly

 

 

when resuming spraying.

 

 

 

 

 

Cannot trigger spray gun.

Spray gun trigger lock is locked.

Rotate trigger safety lever to

 

 

unlock trigger lock, page 10.

 

 

 

Paint is coming out of pressure

Pressure control switch is worn.

Take sprayer to Graco/MAGNUM

control switch.

 

authorized service center.

 

 

 

Prime/Spray valve actuates

System is over pressurizing.

Take sprayer to Graco/MAGNUM

automatically relieving pressure

 

authorized service center.

through prime tube.

 

 

 

 

 

Paint leaks down outside of pump.

Pump packings are worn.

Replace pump packings.

 

 

 

Motor is hot and runs intermit-

Vent holes in enclosure are

Keep vent holes clear of

tently. Motor automatically shuts

plugged or sprayer is covered.

obstructions and overspray and

off due to excessive heat. Dam-

 

keep sprayer open to air.

age can occur if cause is not cor-

 

 

Extension cord is too long or not a

Replace extension cord. Read

rected.

heavy enough gauge.

Grounding and Electrical

See Thermal Overload, page 7.

 

Requirements, page 7.

 

Unregulated electrical generator

Use electrical generator with a

 

being used has excessive voltage.

proper voltage regulator. Sprayer

 

 

requires 120VAC, 60 Hz,

 

 

1500-Watt generator.

 

 

 

312001R

29

Image 29
Contents Agnum ProX7 Models 262800, 262805, 261815Model Model Series B Series DPSI SpecificationsGrounding Fire and Explosion Hazard Skin Injection Hazard Pressurized Aluminum Parts Hazard Electric Shock HazardBurn Hazard Moving Parts HazardFluid supply container follow local code Grounding and Electric RequirementsThermal Overload ProX Sprayers Only Component IdentificationSG2/SG3 Pressure Control Knob Settings Pressure Relief ProcedureOperation Trigger LockPrime and Flush Storage Fluid SetupOil- or Water-based Materials To spray water-based materials after sprayPrime Adjust Spray Pressure Install Tip and Guard on GunSpraying Techniques Preventing Excessive Tip WearUnclogging Spray Tip Getting StartedTriggering Gun Aiming GunChoosing the Correct Tip Tip SelectionSelecting Tip Hole Size Tip Hole SizeUnderstanding Tip Number Reversible Tip Selection ChartTip Fan Width 12 Part Mm from Surface Hole SizeRelieve pressure, Shutdown and CleaningPail Flushing Ti9745a Ti8908a Open Power FlushStop triggering gun. Engage trigger lock Cleaning Gun Cleaning InstaClean Fluid Filter ProX Sprayers OnlyLong Term Storage StorageShort Term Storage Stowing Sprayer Caring for Sprayer Maintenance and ServicePaint Hoses TipsProblem Cause Solution TroubleshootingProX7 and ProX9 Insert screw Read Pump does not prime sec Problem Cause Solution See Thermal Overload, Magnum X5 Series D Magnum X7 Series C Technical DataMagnum ProX7 Magnum ProX9 Series B For Graco Canada Customers Graco Standard Warranty