Graco 312001R important safety instructions Shutdown and Cleaning, Pail Flushing, Relieve pressure

Page 17

Shutdown and Cleaning

Pail Flushing

For short term shutdown periods (overnight to two days) refer to Short Term Storage, page 22.

For flushing after spraying oil-based coatings, use compatible oil-based flushing fluid or min- eral spirits. Read Priming and Flushing Storage Fluid, page 11.

For flushing after spraying water-based coat- ings, use water. Read Priming and Flushing Storage Fluid, page 11 or Power Flush, page 19.

1.Relieve pressure, page 10.

2.Remove tip and guard assembly from gun and place in flushing fluid.

3.Lift suction tube and prime tube from paint pail. Let them drain into paint pail for a while.

4.Separate prime tube (smaller)

from suction tube (larger).

ti2039a

5.Place empty waste and water or solvent pails side by side.

ti9726a

Shutdown and Cleaning

6.Place prime tube in waste pail.

ti9652a

7.Submerge suction tube in water or flushing solvent.

ti9651a

8.Turn pressure control knob to the Prime/Clean setting.

ti9344a

9. Turn power switch ON.

ti5580a

10.Flush until approximately 1/3 of the flushing fluid is emptied from the pail.

11. Turn power switch OFF.

ti2018a

312001R

17

Image 17
Contents Agnum ProX7 Models 262800, 262805, 261815Model Model Series B Series DPSI SpecificationsGrounding Fire and Explosion Hazard Skin Injection Hazard Pressurized Aluminum Parts Hazard Electric Shock HazardBurn Hazard Moving Parts HazardFluid supply container follow local code Grounding and Electric RequirementsThermal Overload ProX Sprayers Only Component IdentificationSG2/SG3 Pressure Control Knob Settings Pressure Relief ProcedureOperation Trigger LockPrime and Flush Storage Fluid SetupOil- or Water-based Materials To spray water-based materials after sprayPrime Adjust Spray Pressure Install Tip and Guard on GunSpraying Techniques Preventing Excessive Tip WearUnclogging Spray Tip Getting StartedTriggering Gun Aiming GunChoosing the Correct Tip Tip SelectionSelecting Tip Hole Size Tip Hole SizeUnderstanding Tip Number Reversible Tip Selection ChartTip Fan Width 12 Part Mm from Surface Hole SizeRelieve pressure, Shutdown and CleaningPail Flushing Ti9745a Ti8908a Open Power FlushStop triggering gun. Engage trigger lock Cleaning Gun Cleaning InstaClean Fluid Filter ProX Sprayers OnlyLong Term Storage StorageShort Term Storage Stowing Sprayer Caring for Sprayer Maintenance and ServicePaint Hoses TipsProblem Cause Solution TroubleshootingProX7 and ProX9 Insert screw Read Pump does not prime sec Problem Cause Solution See Thermal Overload, Magnum X5 Series D Magnum X7 Series C Technical DataMagnum ProX7 Magnum ProX9 Series B For Graco Canada Customers Graco Standard Warranty