Graco 312001R important safety instructions ProX7 and ProX9 Insert screw

Page 26

Troubleshooting

Problem

Cause

Solution

 

 

 

 

 

 

Pump does not prime.

Prime/Spray Valve is in SPRAY

Turn Prime/Spray Valve to PRIME

 

position.

position (pointing down).

 

 

 

 

Inlet screen is clogged or suction

Clean debris off inlet screen and

 

tube is not immersed.

make sure suction tube is

 

 

immersed in fluid.

 

 

 

 

Pump was not primed with

Remove suction tube from paint.

 

flushing fluid.

Prime pump with water or

 

 

solvent-based flushing fluid, page

 

 

11.

 

 

 

 

Inlet valve check ball is stuck.

Remove suction tube and place a

 

 

pencil into the inlet section to dis-

 

 

lodge the ball, allowing pump to

 

 

prime properly. OR Power Flush

 

 

sprayer, page 19.

 

 

 

 

 

AutoPrime may need replace-

 

 

ment. Turn power switch ON and

 

 

listen for “tap” in pump. If you do

 

 

not hear “tap”, AutoPrime is dam-

 

 

aged. Take sprayer to Graco/MAG-

 

 

NUM authorized service center.

 

 

 

 

Inlet valve check ball or seat is

Remove inlet fitting. Clean or

 

dirty

replace ball and seat.

 

 

 

 

Outlet valve check ball is stuck.

ProX7 and ProX9: Insert screw

 

 

driver in slot and remove

 

 

Easy-Accessdoor, page 8.

 

 

Unscrew outlet valve with a 3/4 in.

 

 

socket. Remove and clean

 

 

assembly.

 

 

X5 and X7: Remove outlet fitting

 

 

and clean outlet check ball.

 

 

 

 

Suction tube is leaking.

Tighten suction tube connection.

 

 

Inspect for cracks or vacuum

 

 

leaks.

 

 

 

 

Pump does not prime with fluid.

Remove suction tube from paint.

 

 

Prime pump with water or sol-

 

 

vent-based flushing fluid.

 

 

 

 

Fluids are viscous or sticky.

Some fluids may prime faster if

 

 

the Power Switch is momentarily

 

 

turned off so the pump can slow

 

 

and stop. Repeat several times if

 

 

necessary.

 

 

 

26

312001R

Image 26
Contents Model Models 262800, 262805, 261815Agnum ProX7 Model Series B Series DSpecifications PSIGrounding Fire and Explosion Hazard Skin Injection Hazard Burn Hazard Electric Shock HazardPressurized Aluminum Parts Hazard Moving Parts HazardFluid supply container follow local code Grounding and Electric RequirementsThermal Overload Component Identification ProX Sprayers OnlySG2/SG3 Operation Pressure Relief ProcedurePressure Control Knob Settings Trigger LockOil- or Water-based Materials SetupPrime and Flush Storage Fluid To spray water-based materials after sprayPrime Spraying Techniques Install Tip and Guard on GunAdjust Spray Pressure Preventing Excessive Tip WearTriggering Gun Getting StartedUnclogging Spray Tip Aiming GunSelecting Tip Hole Size Tip SelectionChoosing the Correct Tip Tip Hole SizeTip Fan Width 12 Part Mm from Surface Reversible Tip Selection ChartUnderstanding Tip Number Hole SizeRelieve pressure, Shutdown and CleaningPail Flushing Ti9745a Ti8908a Power Flush OpenStop triggering gun. Engage trigger lock Cleaning InstaClean Fluid Filter ProX Sprayers Only Cleaning GunLong Term Storage StorageShort Term Storage Stowing Sprayer Paint Hoses Maintenance and ServiceCaring for Sprayer TipsTroubleshooting Problem Cause SolutionProX7 and ProX9 Insert screw Read Pump does not prime sec Problem Cause Solution See Thermal Overload, Technical Data Magnum X5 Series D Magnum X7 Series CMagnum ProX7 Magnum ProX9 Series B Graco Standard Warranty For Graco Canada Customers