Graco 312001R Reversible Tip Selection Chart, Understanding Tip Number, Hole Size, 221311 011

Page 16

Setup

Understanding Tip Number

The last three digits of tip number (i.e.: 221413) contain information about hole size and fan width on surface when gun is held 12 in. (30.5 cm) from surface being sprayed.

Reversible Tip Selection Chart

Tip

Fan Width 12 in.

 

Part

(305 mm) from

 

No.

surface

Hole Size

 

 

 

221311

6 - 8 in.

0.011 in.

First digit when doubled

=approximate fan width

413 tip has

8-10 in. fan width

413 tip has a 0.013 in. hole size

ti5559a

 

(152 - 203 mm)

(0.28 mm)

221411

8

- 10 in.

0.011 in.

 

(203 - 254 mm)

(0.28 mm)

 

 

 

 

221313

6

- 8 in.

0.013 in.

 

(152 - 203 mm)

(0.33 mm)

 

 

 

 

221413

8

- 10 in.

0.013 in.

 

(203 - 254 mm)

(0.33 mm)

Last two digits = tip hole size in thousands of an inch

221415

8 - 10 in.

0.015 in.

 

(203 - 254 mm)

(0.38 mm)

 

 

 

221515

10 - 12 in.

0.015 in.

 

(254 - 305 mm)

(0.38 mm)

 

 

 

221417

8 - 10 in.

0.017 in.

 

(203 - 254 mm)

(0.43 mm)

 

 

 

221517

10 - 12 in.

0.017 in.

 

(254 - 305 mm)

(0.43 mm)

 

 

 

221619

12 - 14 in.

0.019 in.

 

(305 - 356 mm)

(0.48 mm)

Example: For an 8 to 10 in. (203 to 254 mm) fan width and 0.013 (0.33 mm) hole size, order Part No. 221413.

16

312001R

Image 16
Contents Models 262800, 262805, 261815 Agnum ProX7Model Model Series B Series DSpecifications PSIGrounding Fire and Explosion Hazard Skin Injection Hazard Electric Shock Hazard Pressurized Aluminum Parts HazardBurn Hazard Moving Parts HazardThermal Overload Grounding and Electric RequirementsFluid supply container follow local code Component Identification ProX Sprayers OnlySG2/SG3 Pressure Relief Procedure Pressure Control Knob SettingsOperation Trigger LockSetup Prime and Flush Storage FluidOil- or Water-based Materials To spray water-based materials after sprayPrime Install Tip and Guard on Gun Adjust Spray PressureSpraying Techniques Preventing Excessive Tip WearGetting Started Unclogging Spray TipTriggering Gun Aiming GunTip Selection Choosing the Correct TipSelecting Tip Hole Size Tip Hole SizeReversible Tip Selection Chart Understanding Tip NumberTip Fan Width 12 Part Mm from Surface Hole SizePail Flushing Shutdown and CleaningRelieve pressure, Ti9745a Ti8908a Power Flush OpenStop triggering gun. Engage trigger lock Cleaning InstaClean Fluid Filter ProX Sprayers Only Cleaning GunShort Term Storage StorageLong Term Storage Stowing Sprayer Maintenance and Service Caring for SprayerPaint Hoses TipsTroubleshooting Problem Cause SolutionProX7 and ProX9 Insert screw Read Pump does not prime sec Problem Cause Solution See Thermal Overload, Technical Data Magnum X5 Series D Magnum X7 Series CMagnum ProX7 Magnum ProX9 Series B Graco Standard Warranty For Graco Canada Customers