Graco 312001R important safety instructions Prime

Page 12

Setup

1. Make sure the power switch is OFF and the sprayer is unplugged.

ti2810a

2. Separate prime tube (smaller) from suction tube (larger).

ti2039a

3.Place prime tube in waste pail.

ti9652a

4. Submerge suction tube in

Allow fluid to flow out of prime tube, into waste pail, for 30 to 60 seconds.

10. Turn power switch OFF.

ti2810a

11.Transfer suction tube to paint pail and submerge suction tube in paint.

ti9653a

12.Turn power switch ON.

13.When you see paint coming out of prime tube:

a.Point gun into waste pail.

b.Unlock gun trigger lock.

c.Pull and hold gun trigger.

water or flushing solvent.

ti9651a

5.Turn Prime/Spray Valve to

PRIME.

d.Turn Prime/Spray valve to

SPRAY.

NOTE: Some fluids may prime faster if the Power Switch is momentarily turned off so the pump can slow and stop. Repeat several times if necessary.

ti8909a

ti9345a

ti9346a

6. Plug sprayer in a grounded outlet.

7. Turn power switch ON.

ti5580a

8.Align setting indicator with Prime/Clean setting on Pressure Control knob until pump starts, page 10.

ti9718a

9.When sprayer starts pumping, flushing solvent and air bubbles will be purged from system.

14.Continue to trigger gun into waste pail until you see only paint coming out of gun.

15.Release trigger. Engage trigger lock.

16.Transfer prime tube to paint pail

and clip prime tube to suction

ti8908a

tube.

 

NOTE: Motor stopping indicates pump and hose are primed with paint. If motor continues to run the sprayer is not properly primed. To reprime, turn Prime/Spray valve to PRIME and repeat step 12.

12

312001R

Image 12
Contents Models 262800, 262805, 261815 Agnum ProX7Model Model Series B Series DSpecifications PSIGrounding Fire and Explosion Hazard Skin Injection Hazard Electric Shock Hazard Pressurized Aluminum Parts HazardBurn Hazard Moving Parts HazardGrounding and Electric Requirements Thermal OverloadFluid supply container follow local code Component Identification ProX Sprayers OnlySG2/SG3 Pressure Relief Procedure Pressure Control Knob SettingsOperation Trigger LockSetup Prime and Flush Storage FluidOil- or Water-based Materials To spray water-based materials after sprayPrime Install Tip and Guard on Gun Adjust Spray PressureSpraying Techniques Preventing Excessive Tip WearGetting Started Unclogging Spray TipTriggering Gun Aiming GunTip Selection Choosing the Correct TipSelecting Tip Hole Size Tip Hole SizeReversible Tip Selection Chart Understanding Tip NumberTip Fan Width 12 Part Mm from Surface Hole SizeShutdown and Cleaning Pail FlushingRelieve pressure, Ti9745a Ti8908a Power Flush OpenStop triggering gun. Engage trigger lock Cleaning InstaClean Fluid Filter ProX Sprayers Only Cleaning GunStorage Short Term StorageLong Term Storage Stowing Sprayer Maintenance and Service Caring for SprayerPaint Hoses TipsTroubleshooting Problem Cause SolutionProX7 and ProX9 Insert screw Read Pump does not prime sec Problem Cause Solution See Thermal Overload, Technical Data Magnum X5 Series D Magnum X7 Series CMagnum ProX7 Magnum ProX9 Series B Graco Standard Warranty For Graco Canada Customers