Graco 312001R important safety instructions Short Term Storage, Long Term Storage

Page 22

Storage

Storage

Short Term Storage

(up to 2 days)

1.Relieve pressure, page 10.

2.Leave suction tube and prime tube in paint pail.

ti9353b

3.Cover paint pail and hoses tightly with plastic wrap.

ti9350a

4.

a.Engage trigger lock.

b.Leave gun attached to

hose.ti8908a

c.If you have not already cleaned them, remove

tip and guard from gun and clean with water or flushing solvent. A soft

brush can be used to ti9671a loosen and remove

dried on material if needed.

d.Wipe paint off outside of gun using a soft cloth moistened with water or flushing sol- vent.

Long Term Storage

(more than 2 days)

Always circulate Pump Armor storage fluid through system after cleaning. Water left in sprayer will cor- rode and damage pump. Follow Shutdown and Cleaning, page 17, or Power Flush Cleaning, page 19.

1.Place suction tube in Pump Armor storage

fluid bottle and prime tube in waste pail.

ti2057a

2.Turn Prime/Spray valve to PRIME.

ti9346a

3. Turn power switch ON.

ti5580a

4.Turn pressure control knob clockwise until the pump turns on.

ti9343b

5. When storage fluid comes out of prime tube (5-10 seconds) turn power switch OFF.

ti2018a

6.Turn Prime/Spray valve to SPRAY to keep storage fluid in sprayer during storage.

ti9345a

22

312001R

Image 22
Contents Model Models 262800, 262805, 261815Agnum ProX7 Model Series B Series DSpecifications PSIGrounding Fire and Explosion Hazard Skin Injection Hazard Burn Hazard Electric Shock HazardPressurized Aluminum Parts Hazard Moving Parts HazardThermal Overload Grounding and Electric RequirementsFluid supply container follow local code Component Identification ProX Sprayers OnlySG2/SG3 Operation Pressure Relief ProcedurePressure Control Knob Settings Trigger LockOil- or Water-based Materials SetupPrime and Flush Storage Fluid To spray water-based materials after sprayPrime Spraying Techniques Install Tip and Guard on GunAdjust Spray Pressure Preventing Excessive Tip WearTriggering Gun Getting StartedUnclogging Spray Tip Aiming GunSelecting Tip Hole Size Tip SelectionChoosing the Correct Tip Tip Hole SizeTip Fan Width 12 Part Mm from Surface Reversible Tip Selection ChartUnderstanding Tip Number Hole SizePail Flushing Shutdown and CleaningRelieve pressure, Ti9745a Ti8908a Power Flush OpenStop triggering gun. Engage trigger lock Cleaning InstaClean Fluid Filter ProX Sprayers Only Cleaning GunShort Term Storage StorageLong Term Storage Stowing Sprayer Paint Hoses Maintenance and ServiceCaring for Sprayer TipsTroubleshooting Problem Cause SolutionProX7 and ProX9 Insert screw Read Pump does not prime sec Problem Cause Solution See Thermal Overload, Technical Data Magnum X5 Series D Magnum X7 Series CMagnum ProX7 Magnum ProX9 Series B Graco Standard Warranty For Graco Canada Customers