Graco 312001R Cleaning InstaClean Fluid Filter ProX Sprayers Only, Cleaning Gun

Page 21

Cleaning InstaCleanFluid Filter (ProX Sprayers Only)

The InstaClean Fluid Filter prevents particles from entering paint hose. After each use, remove and clean it to insure peak performance.

Shutdown and Cleaning

4.Tighten outlet fitting and reconnect hose (a) to sprayer. Use two wrenches to tighten securely.

a

ti9674b

1.Relieve pressure, page 10.

2.

a.

Disconnect airless

 

b

 

spray hose (a) from

 

 

 

 

 

sprayer

c

 

b.

Unscrew outlet fitting

 

 

 

(b).

ti9347a

a

 

 

 

c.Remove InstaClean Fluid Filter (c).

3.Check InstaClean Fluid Filter (c) for debris. If needed, clean filter with water and a soft brush.

a.Install closed (square) end of InstaClean Fluid Filter (c) in sprayer.

b. Screw outlet fitting (b)

 

into sprayer.

c

b

ti9347a

Cleaning Gun

Clean gun fluid filter (d) with water or flushing solvent and a brush every time you flush the system. Replace gun filter if damaged.

Remove tip and guard and clean with water or flushing solvent. A soft brush can be used to loosen and remove dried on material if needed.

Wipe paint off outside of gun using a soft cloth moistened with water or flushing solvent.

d

ti9668a

ti9671a

312001R

21

Image 21
Contents Agnum ProX7 Models 262800, 262805, 261815Model Model Series B Series DPSI SpecificationsGrounding Fire and Explosion Hazard Skin Injection Hazard Pressurized Aluminum Parts Hazard Electric Shock HazardBurn Hazard Moving Parts HazardGrounding and Electric Requirements Thermal OverloadFluid supply container follow local code ProX Sprayers Only Component IdentificationSG2/SG3 Pressure Control Knob Settings Pressure Relief ProcedureOperation Trigger LockPrime and Flush Storage Fluid SetupOil- or Water-based Materials To spray water-based materials after sprayPrime Adjust Spray Pressure Install Tip and Guard on GunSpraying Techniques Preventing Excessive Tip WearUnclogging Spray Tip Getting StartedTriggering Gun Aiming GunChoosing the Correct Tip Tip SelectionSelecting Tip Hole Size Tip Hole SizeUnderstanding Tip Number Reversible Tip Selection ChartTip Fan Width 12 Part Mm from Surface Hole SizeShutdown and Cleaning Pail FlushingRelieve pressure, Ti9745a Ti8908a Open Power FlushStop triggering gun. Engage trigger lock Cleaning Gun Cleaning InstaClean Fluid Filter ProX Sprayers OnlyStorage Short Term StorageLong Term Storage Stowing Sprayer Caring for Sprayer Maintenance and ServicePaint Hoses TipsProblem Cause Solution TroubleshootingProX7 and ProX9 Insert screw Read Pump does not prime sec Problem Cause Solution See Thermal Overload, Magnum X5 Series D Magnum X7 Series C Technical DataMagnum ProX7 Magnum ProX9 Series B For Graco Canada Customers Graco Standard Warranty