Graco 312001R Setup, Prime and Flush Storage Fluid, Oil- or Water-based Materials

Page 11

Setup

1.Unscrew tip and guard assembly from gun.

ti9714a

2.Uncoil hose and connect one end to gun. Use two wrenches to tighten securely

Setup

Prime and Flush Storage Fluid

NOTE: To spray lacquers with the ProX7 or ProX9, you must purchase lacquer conversion kit 256212, and follow priming procedure for oil-based materi- als. The X5 and X7 units are not intended for lac- quers.

Before you use your sprayer for the first time or be- gin a new spraying project, you need to prime the sprayer and flush the storage fluid out of the spray- er.

Oil- or Water-based Materials

3.Connect other end of hose to sprayer.

ti11456a

ti9681a

ti9674b

• When spraying water-basedmaterials, flush

the system thoroughly with water.

• When spraying oil-basedmaterials, flush the

system thoroughly with mineral spirits or com-

patible, oil-based flushing solvent.

• To spray water-based materials after spray-

ing oil-basedmaterials, flush the system thor-

oughly with water first. The water flowing out of

prime tube should be clear and solvent-free

before you begin spraying the water-based

(X5 & X7) (ProX7 & ProX9)

NOTE: If hose is already connected, make sure connections are tight.

4. Turn OFF power switch.

ti2810a

5.Turn Pressure Control Knob all the way left (counter-clockwise) to minimum pressure.

ti9344a

material.

• To spray oil-based materials after spraying

water-basedmaterials, flush the system thor-

oughly with mineral spirits or a compatible

oil-based flushing solvent first. The solvent

flowing out of the prime tube should not contain

any water.

• When flushing with solvents, ground pail and

gun. Read Grounding and Electric Require-

ments, page 7.

• To avoid fluid splashing back on your skin or

into your eyes, always aim gun at inside wall of

pail.

312001R

11

Image 11
Contents Model Series B Series D Models 262800, 262805, 261815Agnum ProX7 ModelPSI SpecificationsGrounding Fire and Explosion Hazard Skin Injection Hazard Moving Parts Hazard Electric Shock HazardPressurized Aluminum Parts Hazard Burn HazardFluid supply container follow local code Grounding and Electric RequirementsThermal Overload ProX Sprayers Only Component IdentificationSG2/SG3 Trigger Lock Pressure Relief ProcedurePressure Control Knob Settings OperationTo spray water-based materials after spray SetupPrime and Flush Storage Fluid Oil- or Water-based MaterialsPrime Preventing Excessive Tip Wear Install Tip and Guard on GunAdjust Spray Pressure Spraying TechniquesAiming Gun Getting StartedUnclogging Spray Tip Triggering GunTip Hole Size Tip SelectionChoosing the Correct Tip Selecting Tip Hole SizeHole Size Reversible Tip Selection ChartUnderstanding Tip Number Tip Fan Width 12 Part Mm from SurfaceRelieve pressure, Shutdown and CleaningPail Flushing Ti9745a Ti8908a Open Power FlushStop triggering gun. Engage trigger lock Cleaning Gun Cleaning InstaClean Fluid Filter ProX Sprayers OnlyLong Term Storage StorageShort Term Storage Stowing Sprayer Tips Maintenance and ServiceCaring for Sprayer Paint HosesProblem Cause Solution TroubleshootingProX7 and ProX9 Insert screw Read Pump does not prime sec Problem Cause Solution See Thermal Overload, Magnum X5 Series D Magnum X7 Series C Technical DataMagnum ProX7 Magnum ProX9 Series B For Graco Canada Customers Graco Standard Warranty